Standalone Access Controller and Reader -QU M2
1
1
Description& Features
.1 Description:
QU- a waterproof standalone access control, reading EM&HID card, uses advanced Microprocessor, with high-capacity ash memory for M2 is it
0000 users. Users added and deleted via admin card, very simple operate. The infrared remote control make the device not only have alarm, can be to
1
protection, two units interlocked, anti-passback function but also make two units interlocked, add and delete the user the remote control key can on
directly.
Besides, has low power consumption design, anti-theft alarm, door release button ect. , all these make convenient, safe and reliable. it it
1
Features:
Feature
Description
Rainproof, moistureproof , durable
Longer working life, more stable performance
10000 card users
Waterproof Design
Ultralow power consumption
Large capacity
wiegand reader
Can used wiegand output reader as 26
Can connect EM/IC/HIDwiegand output reader 26
two units can interlocked online be
Single door two doors anti-passback or
Connect external reader
two units interlocked
Anti-passback
2
2
2
2
2
2
Installation, wiring, diagram
.1 Installation
.1.1 Drill the holes according the distance and the dimension the back cover, install the distributing box. to on or
.1.2 Thread the cable through the cable hole, connect wires needed, wrapped Unused wires with insulating tape case in of short circuit
.1.3 Fix the back cover the wall with special screw on
.1.4 Fix the front cover the back cover with the screws to
2
.2 Wiring
No.
1
Marks
RESET
GND
Color
Pink
Description
RESET
2
Pink
RESET
3
D0
Green
White
Gray
Wiegand output D0
Wiegand output D1
Alarm
4
D1
5
ALARM-
OPEN
D_IN
+12V
6
Yellow
Brown
Red
Exit button
7
Door contact switch
+12V Input
8
9
GND
NO
Black
Blue
GND
1
0
1
2
Relay end NO
Relay Com
Relay NC end
1
1
COM
NC
Purple
Orange
Note Please check all wires and install front cover carefully before power on.
2
.4 Diagram
3
Factory Reset and Set management card
Connect the two pink wiresthen power on. After the sound“ ”didi , Factory reset nished. When indication turns greenis LED it means you
can set two admin cards now read the rst card admin add card the second card admin delete card then LED turns red ash after this, this as as , ,
device work ,resetting factory default. can to
Note Reset factory default wont delete user cards, present the same card when second read, the device will sound error reminding If you
dididi , then continue present another card. operations within 10seconds, the device will enter working mode automatically , you can If no
parameter reset factory default. to
Admin setting on keypad
4

Especificaciones del producto

Marca: QUIO
Categoría: No categorizado
Modelo: QU-M2-LF
Color del producto: Wit
Código de seguridad internacional (IP): IP20
Tipo de sensor de imagen: Passieve infraroodsensor (PIR)
Rango maximo: 8 m
Dimensiones (Ancho x Fondo x Alto): 116 x 20 x 80 mm
Alcance máximo en exteriores: 100 m
Sensibilidad a la luz: 1000 Lux

¿Necesitas ayuda?

Si necesitas ayuda con QUIO QU-M2-LF haz una pregunta a continuación y otros usuarios te responderán