DVM S
AM JXVHGH Series✴✴✴
AM JXVHGR Series✴✴✴
AM HXVAGH Series✴✴✴
AM JXVAGH Series✴✴✴
Air Conditioner
installation manual
imagine the possibilities
Thank you for purchasing this Samsung product.
2
Contents
Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Preparing for installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Selecting installation location. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Space requirement for installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Base construction and installation of the outdoor unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Installing the wind/snow prevention duct . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Refrigerant pipe installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Electrical wiring work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
Air tightness test and vacuum drying. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86
Pipe insulation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88
Charging refrigerant. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92
Basic segment display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95
Setting outdoor unit option switch and key function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95
Setting the MCU and Pipe Addresses (for HR Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .105
Things to check after completing the installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109
Inspection and test operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .110
Inspection and trial operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112
Automatic refrigerant amount detection function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116
Correct Disposal of This Product
(Waste Electrical & Electronic Equipment)
(Applicable in countries with separate collection systems)
This marking on the product, accessories or literature indicates that the product and its electronic
accessories (e.g. charger, headset, USB cable) should not be disposed of with other household waste at the
end of their working life. To prevent possible harm to the environment or human health from uncontrolled
waste disposal, please separate these items from other types of waste and recycle them responsibly to
promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their local
government oce, for details of where and how they can take these items for environmentally safe
recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract.
This product and its electronic accessories should not be mixed with other commercial wastes for disposal.
For information on Samsung’s environmental commitments and product-specic regulatory
obligations, e.g. REACH, WEEE, Batteries, visit : samsung.com/uk/aboutsamsung/samsungelectronics/
corporatecitizenship/data_corner.html
3
ENGLISH
Safety precautions
Please follow the following safety information for safety of the installer and the user.
❇ DVM S air conditioner uses R-410A refrigerant.
• When using R-410A, moisture or foreign substances may aect the performance and reliability of the
product. Safety precautions must be obeyed when installing the refrigerant pipe.
• The designed maximum pressure of the system is 4.1MPa and therefore select appropriate material and
thickness according to the regulations.
• R-410A is a quasi-azeotrope of two refrigerants and it has to be charged in liquid phase when lling the
refrigerant. (If you charge vapor refrigerant, it may change the blend of the refrigerant and cause product
malfunction.)
❇ You must connect the indoor units for R-410A refrigerant. Refer to product catalog to nd out the models
names for connectable indoor units. (If you connect the indoor units that are not designed for R-410A, it
cannot operated normally.)
❇ After completing the installation and trial operation, explain to the user how to use and maintain the product. Also,
hand over this installation manual so that it can be stored by the user.
❇ Manufacturer is not responsible for the incidents occurred by improper installation. Installer is responsible for
any installation related claims from the user occurred by neglecting warnings and cautions stated in this manual.
(Installer will be responsible for any service charges that may occur)
❇ Generally, system air conditioners should not be relocated after installation. But when it has to be relocated for
inevitable reasons, please contact Samsung’s qualied dealers for system air conditioners.
WARNING • Hazards or unsafe practices that may result in severe personal injury or death.
CAUTION • Hazards or unsafe practices that may result in minor personal injury (to installer/user) or
property damage.
SEVERE WARNING SIGNS
Consult qualied installer or dealer for installation.
X When installation is done by unqualied person, problems such as water leakage, electric shock or re may occur.
Installation work must be done properly according to this installation manual.
X When installation is not done properly, it may cause water leakage, electric shock or re.
When installing the unit in a small room, take measure to keep the refrigerant concentration from exceeding
allowable safety limits in case of refrigerant leakage. Consult the dealer for precautionary measure before the
installation.
X When refrigerant leaks and exceed dangerous concentration level, it may cause suocation accidents.
If any gas or impurities, except R-410A refrigerant, come into the refrigerant pipe, serious problem may occur and
it may cause injury.
Use the supplied accessories, specied components and tools for the installation.
X Do not use the pipe and the installation product used for the R-22 refrigerant.
X Failure to use the specied components can cause product fall down, water leakage, electrical shock, and re. (The
pipe and are components used for R-22 refrigerant must not be used)
Install the outdoor unit on a hard and even place that can support its weight.
X If the place cannot support its weight, the outdoor unit may fall down and it may cause injury.
Especificaciones del producto
Marca: | Samsung |
Categoría: | Airco |
Modelo: | AM100JXVAGH/EU |
¿Necesitas ayuda?
Si necesitas ayuda con Samsung AM100JXVAGH/EU haz una pregunta a continuación y otros usuarios te responderán
Airco Samsung Manuales
14 Septiembre 2024
14 Septiembre 2024
14 Septiembre 2024
11 Septiembre 2024
7 Septiembre 2024
6 Septiembre 2024
2 Septiembre 2024
2 Septiembre 2024
2 Septiembre 2024
2 Septiembre 2024
Airco Manuales
- Airco Zibro
- Airco Electrolux
- Airco LG
- Airco AEG
- Airco Panasonic
- Airco BEKO
- Airco Delonghi
- Airco Daewoo
- Airco Grundig
- Airco Honeywell
- Airco Inventum
- Airco Siemens
- Airco Toshiba
- Airco Unold
- Airco Whirlpool
- Airco Vaillant
- Airco Adler
- Airco Amana
- Airco Argo
- Airco Arcelik
- Airco Bartscher
- Airco Tosot
- Airco Eurom
- Airco GE
- Airco Orbegozo
- Airco Sharp
- Airco Klarstein
- Airco Gorenje
- Airco Hitachi
- Airco Nedis
- Airco Thomson
- Airco Innoliving
- Airco Tristar
- Airco Domo
- Airco Trisa
- Airco Hotpoint-Ariston
- Airco Rowenta
- Airco Livoo
- Airco Manta
- Airco SereneLife
- Airco Hisense
- Airco Hyundai
- Airco Vox
- Airco Westinghouse
- Airco Emerio
- Airco RCA
- Airco Clatronic
- Airco Hotpoint
- Airco Sencor
- Airco Midea
- Airco Blaupunkt
- Airco Mabe
- Airco Frigidaire
- Airco Svan
- Airco Logik
- Airco Danby
- Airco Anslut
- Airco Daikin
- Airco Carson
- Airco Mesko
- Airco Profilo
- Airco Tripp Lite
- Airco Truma
- Airco Heinner
- Airco Sanyo
- Airco Jocca
- Airco Einhell
- Airco Kenmore
- Airco Philco
- Airco TCL
- Airco Guzzanti
- Airco Defy
- Airco Infiniton
- Airco Mitsubishi
- Airco Dometic
- Airco Aspes
- Airco Dimplex
- Airco DCG
- Airco Emerson
- Airco White Knight
- Airco Suntec
- Airco Orima
- Airco Haier
- Airco Gree
- Airco Evolar
- Airco Proline
- Airco Royal Sovereign
- Airco Corberó
- Airco Zelmer
- Airco Meaco
- Airco Fujitsu
- Airco Kelvinator
- Airco Element
- Airco Malmbergs
- Airco Everglades
- Airco Daitsu
- Airco Sanus
- Airco Wilfa
- Airco Carrier
- Airco Olimpia Splendid
- Airco Trotec
- Airco Saunier Duval
- Airco Camry
- Airco Qlima
- Airco Alpatec
- Airco Jocel
- Airco Comfee
- Airco Godrej
- Airco Sauber
- Airco Maiko
- Airco Tectro
- Airco Rotel
- Airco Becken
- Airco Bavaria
- Airco Equation
- Airco Edy
- Airco HTW
- Airco Maxicool
- Airco Dantherm
- Airco Thermex
- Airco Master
- Airco MundoClima
- Airco Argoclima
- Airco Baxi
- Airco Proklima
- Airco Sonnenkonig
- Airco Lavorwash
- Airco Climadiff
- Airco Fairland
- Airco Toyotomi
- Airco Just Fire
- Airco Furrion
- Airco Cecotec
- Airco Iceberg
- Airco Livington
- Airco Firstline
- Airco Holland Electro
- Airco Evapolar
- Airco EcoFlow
- Airco NewAir
- Airco Kogan
- Airco ActronAir
- Airco Klimaire
- Airco SEEGER
- Airco General Electric
- Airco Friedrich
- Airco Simplicity
- Airco Starlyf
- Airco Moa
- Airco Fuji Electric
- Airco Kibernetik
- Airco Prem-i-air
- Airco Céliera
- Airco Bodin
- Airco Brivis
- Airco MRCOOL
- Airco B-Air
- Airco Rinnai
- Airco GoldAir
- Airco Ravanson
- Airco Daizuki
- Airco Evapcool
- Airco Protector
- Airco Krone
- Airco ARCTIC WIND
- Airco Keystone
- Airco Cool-Space
- Airco VänEE
- Airco Perfect Aire
Últimos Airco Manuales
19 Septiembre 2024
19 Septiembre 2024
19 Septiembre 2024
19 Septiembre 2024
19 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024