Siemens LC67KIM60 Manual de Usario

Lee a continuación 📖 el manual en español para Siemens LC67KIM60 (20 páginas) en la categoría campana extractora. Esta guía fue útil para 7 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/20
Register
your
product
online
siemens-home.bsh-group.com/welcome
en ,QVWUXFWLRQVIRULQVWDOODWLRQDQGXVH
Extractor hood
en
2
Table of contents
enI ns t r u ct i on s f or i n s t al l a t i on and us e
INSTRUCTION MANUAL.......................................................... 2
8Intended use................................................................... 2
(Important safety information........................................ 3
7Environmental protection ............................................. 5
ÇOperating modes ........................................................... 5
1Operating the appliance................................................ 6
2Cleaning and maintenance ........................................... 6
3Trouble shooting ........................................................... 8
4Customer service .......................................................... 9
INSTALLATION INSTRUCTIONS .......................................... 10
(Important safety information...................................... 11
KGeneral information .................................................... 13
5Installation ................................................................... 14
INSTRUCTION MANUAL
Produktinfo
Additional information on products, accessories,
replacement parts and services can be found at
www.siemens-home.bsh-group.com and in the online
shop www.siemens-home.bsh-group.com/eshops
8Intended use
I nt en ded use
Read these instructions carefully. Only then
will you be able to operate your appliance
safely and correctly. Retain the instruction
manual and installation instructions for future
use or for subsequent owners.
The appliance can only be used safely if it is
correctly installed according to the safety
instructions. The installer is responsible for
ensuring that the appliance works perfectly at
its installation location.
This appliance is intended for domestic use
and the household environment only. The
appliance is not intended for use outside. Do
not leave the appliance unattended during
operation. The manufacturer is not liable for
damage which is caused by improper use or
incorrect operation.
This appliance is intended for use up to a
maximum height of 2000 metres above sea
level.
This appliance may be used by children over
the age of 8 years old and by persons with
reduced physical, sensory or mental capacity
or by persons with a lack of experience or
knowledge if they are supervised by someone
who is responsible for their safety, or have
been instructed in how to use the appliance
safely and have understood the risks involved
in not using it properly.
Children must not play with the
appliance.Cleaning and user maintenance
must not be performed by children unless they
are over 15 years of age and are supervised.
Keep children below the age of 8 years old at
a safe distance from the appliance and power
cable.
Check the appliance for damage after
unpacking it. Do not connect the appliance if it
has been damaged in transport.
This appliance is not intended for operation
with an external clock timer or a remote
control.
Important safety information en
3
(Important safety
information
I mpo r t an t saf e t y i n f o r mat i o n
:Warning
Danger of suffocation!
Packaging material is dangerous to children.
Never allow children to play with packaging
material.
:Warning
Danger of death!
Risk of poisoning from flue gases that are
drawn back in.
Always ensure adequate fresh air in the room
if the appliance is being operated in exhaust
air mode at the same time as room air-
dependent heat-producing appliance is being
operated.
Room air-dependent heat-producing
appliances (e.g. gas, oil, wood or coal-
operated heaters, continuous flow heaters or
water heaters) obtain combustion air from the
room in which they are installed and discharge
the exhaust gases into the open air through an
exhaust gas system (e.g. a chimney).
In combination with an activated vapour
extractor hood, room air is extracted from the
kitchen and neighbouring rooms - a partial
vacuum is produced if not enough fresh air is
supplied. Toxic gases from the chimney or the
extraction shaft are sucked back into the living
space.
Adequate incoming air must therefore
always be ensured.
An incoming/exhaust air wall box alone will
not ensure compliance with the limit.
Safe operation is possible only when the
partial vacuum in the place where the heat-
producing appliance is installed does not
exceed 4 Pa (0.04 mbar). This can be
achieved when the air needed for combustion
is able to enter through openings that cannot
be sealed, for example in doors, windows,
incoming/exhaust air wall boxes or by other
technical means.
In any case, consult your responsible Master
Chimney Sweep. He is able to assess the
house's entire ventilation setup and will
suggest the suitable ventilation measures to
you.
Unrestricted operation is possible if the vapour
extractor hood is operated exclusively in the
circulating-air mode.
:Warning
Risk of fire!
Fatty deposits in the grease filter may catch
fire. Regularly clean the grease filter. Never
operate the appliance without a grease
filter.
Risk of fire!
Grease deposits in the grease filter may
catch fire. Never work with naked flames
close to the appliance (e.g. flambéing). Do
not install the appliance near a heat-
producing appliance for solid fuel (e.g.
wood or coal) unless a closed, non-
removable cover is available. There must
be no flying sparks.
Risk of fire!
Hot oil and fat can ignite very quickly. Never
leave hot fat or oil unattended. Never use
water to put out burning oil or fat. Switch off
the hotplate. Extinguish flames carefully
using a lid, fire blanket or something similar.
Risk of fire!
When gas burners are in operation without
any cookware placed on them, they can
build up a lot of heat. A ventilation
appliance installed above the cooker may
become damaged or catch fire. Only
operate the gas burners with cookware on
them.
Risk of fire!
Operating several gas burners at the same
time gives rise to a great deal of heat. A
ventilation appliance installed above the
cooker may become damaged or catch fire.
Never operate two gas burners
simultaneously on the highest flame for
longer than 15 minutes. One large burner of
more than 5 kW (wok) is equivalent to the
power of two gas burners.

Especificaciones del producto

Marca: Siemens
Categoría: campana extractora
Modelo: LC67KIM60

¿Necesitas ayuda?

Si necesitas ayuda con Siemens LC67KIM60 haz una pregunta a continuación y otros usuarios te responderán




campana extractora Siemens Manuales

campana extractora Manuales

Últimos campana extractora Manuales