VXNET SERIES
Professional Ioudspeakers
Quick Start Guide
Important Safety Instructions
The lightning ξ˜–ash with arrowhead symbol within an
equilateral triangle, is intended to alert the user to the
presence of uninsulated "dangerous voltage " within the
product's enclosure that may be of suξ˜ƒcient magnitude
to constitute a risk of electric shock to persons.
1.ξ˜ƒ Readξ˜ƒtheseξ˜ƒinstructions.ξ˜ƒ
2.ξ˜ƒ Keepξ˜ƒtheseξ˜ƒinstructionsξ˜ƒ
3.ξ˜ƒ Heedξ˜ƒallξ˜ƒwarnings.ξ˜ƒ
4.ξ˜ƒ Followξ˜ƒallξ˜ƒinstructions.ξ˜ƒ
5.ξ˜ƒ Doξ˜ƒnotξ˜ƒuseξ˜ƒthisξ˜ƒapparatusξ˜ƒnearξ˜ƒwater.ξ˜ƒ
6.ξ˜ƒ Cleanξ˜ƒonlyξ˜ƒwithξ˜ƒaξ˜ƒdryξ˜ƒcloth.ξ˜ƒ
7.ξ˜ƒ Doξ˜ƒ notξ˜ƒ blockξ˜ƒ anyξ˜ƒ ventilationξ˜ƒ openings.ξ˜ƒ Installξ˜ƒ inξ˜ƒ accordanceξ˜ƒξ˜ƒ
ξ˜ƒ withξ˜ƒtheξ˜ƒmanufacturer’sξ˜ƒinstructions.ξ˜ƒ
8.ξ˜ƒ Doξ˜ƒ notξ˜ƒ installξ˜ƒ nearξ˜ƒ anyξ˜ƒ heatξ˜ƒ sourcesξ˜ƒ suchξ˜ƒ asξ˜ƒ radiators,ξ˜ƒ heatξ˜ƒξ˜ƒ
ξ˜ƒ registers,ξ˜ƒ stoves,ξ˜ƒ orξ˜ƒ otherξ˜ƒ apparatusξ˜ƒ (includingξ˜ƒ ampliξ›„ersξ˜ƒ thatξ˜ƒξ˜ƒ
ξ˜ƒ produceξ˜ƒheat.ξ˜ƒ
9.ξ˜ƒ Onlyξ˜ƒuseξ˜ƒattachments/accessoriesξ˜ƒspeciξ›„edξ˜ƒbyξ˜ƒtheξ˜ƒmanufacturer.ξ˜ƒ
10.ξ˜ƒ Useξ˜ƒonlyξ˜ƒwithξ˜ƒaξ˜ƒcart,ξ˜ƒstand,ξ˜ƒtripod,ξ˜ƒbracket,ξ˜ƒorξ˜ƒtableξ˜ƒspeciξ›„edξ˜ƒbyξ˜ƒξ˜ƒ
ξ˜ƒ theξ˜ƒ manufacturer,ξ˜ƒ orξ˜ƒ soldξ˜ƒ withξ˜ƒ theξ˜ƒ apparatus.ξ˜ƒ Whenξ˜ƒ aξ˜ƒ cartξ˜ƒ isξ˜ƒ
ξ˜ƒ used,ξ˜ƒuseξ˜ƒcautionξ˜ƒwhenξ˜ƒmovingξ˜ƒtheξ˜ƒcart/apparatusξ˜ƒξ˜ƒcombinationξ˜ƒ
ξ˜ƒ toξ˜ƒavoidξ˜ƒinjuryξ˜ƒfromξ˜ƒtip-over.ξ˜ƒ
11.ξ˜ƒ Referξ˜ƒallξ˜ƒservicingξ˜ƒtoξ˜ƒqualiξ›„edξ˜ƒserviceξ˜ƒpersonnel.ξ˜ƒServicingξ˜ƒ
ξ˜ƒ isξ˜ƒrequiredξ˜ƒwhenξ˜ƒtheξ˜ƒapparatusξ˜ƒhasξ˜ƒbeenξ˜ƒdamagedξ˜ƒinξ˜ƒanyξ˜ƒway,
ξ˜ƒ suchξ˜ƒasξ˜ƒpower-supplyξ˜ƒcordξ˜ƒorξ˜ƒplugξ˜ƒisξ˜ƒdamaged,ξ˜ƒliquidξ˜ƒhasξ˜ƒbeenξ˜ƒξ˜ƒ
ξ˜ƒ spilledξ˜ƒ orξ˜ƒ objectsξ˜ƒ haveξ˜ƒ fallenξ˜ƒ intoξ˜ƒ theξ˜ƒ apparatus,ξ˜ƒ theξ˜ƒ apparatusξ˜ƒ
ξ˜ƒ hasξ˜ƒbeenξ˜ƒexposedξ˜ƒtoξ˜ƒrainξ˜ƒorξ˜ƒmoisture,ξ˜ƒdoesξ˜ƒnotξ˜ƒoperateξ˜ƒnormally,ξ˜ƒ
ξ˜ƒ orξ˜ƒhasξ˜ƒbeenξ˜ƒdropped.ξ˜ƒ
12.ξ˜ƒ Useξ˜ƒonlyξ˜ƒwithξ˜ƒtheξ˜ƒcart,ξ˜ƒstand,ξ˜ƒtripod,ξ˜ƒbracket,ξ˜ƒorξ˜ƒtableξ˜ƒspeciξ›„edξ˜ƒ
ξ˜ƒ byξ˜ƒtheξ˜ƒmanufacturer,ξ˜ƒorξ˜ƒsoldξ˜ƒwithξ˜ƒtheξ˜ƒapparatus.ξ˜ƒWhenξ˜ƒaξ˜ƒcartξ˜ƒisξ˜ƒξ˜ƒ
ξ˜ƒ used,ξ˜ƒuseξ˜ƒcautionξ˜ƒwhenξ˜ƒmovingξ˜ƒtheξ˜ƒcart/apparatusξ˜ƒcombinationξ˜ƒ
ξ˜ƒ toξ˜ƒavoidξ˜ƒinjurtξ˜ƒfromξ˜ƒtip-over.ξ˜ƒ
13.ξ˜ƒ Unplugξ˜ƒ thisξ˜ƒ apparatusξ˜ƒ duringξ˜ƒlightningξ˜ƒ stormsξ˜ƒ orξ˜ƒ whenξ˜ƒ unusedξ˜ƒ
ξ˜ƒ forξ˜ƒlongξ˜ƒperiodsξ˜ƒofξ˜ƒtime.ξ˜ƒ
14ξ˜ƒ Referξ˜ƒ allξ˜ƒ servicingξ˜ƒ toξ˜ƒ qualiξ›„edξ˜ƒ serviceξ˜ƒ personnel.ξ˜ƒ Servicingξ˜ƒ isξ˜ƒξ˜ƒ
ξ˜ƒ requiredξ˜ƒ whenξ˜ƒ theξ˜ƒ apparatusξ˜ƒ hasξ˜ƒ beenξ˜ƒ damagedξ˜ƒ inξ˜ƒ anyξ˜ƒ way,ξ˜ƒ
ξ˜ƒ suchξ˜ƒasξ˜ƒpower-supplyξ˜ƒcordξ˜ƒorξ˜ƒplugξ˜ƒisξ˜ƒdamaged.ξ˜ƒliquidξ˜ƒhasξ˜ƒbeenξ˜ƒξ˜ƒ
ξ˜ƒ spilledξ˜ƒ orξ˜ƒ objectsξ˜ƒ haveξ˜ƒ fallenξ˜ƒ intoξ˜ƒ theξ˜ƒ apparatus,ξ˜ƒ theξ˜ƒ apparatusξ˜ƒξ˜ƒ
ξ˜ƒ hasξ˜ƒ beenξ˜ƒ ξ˜ƒ exposedξ˜ƒ toξ˜ƒ rainξ˜ƒ orξ˜ƒ moisture,ξ˜ƒ doesξ˜ƒ notξ˜ƒ operateξ˜ƒξ˜ƒ
ξ˜ƒ normally,ξ˜ƒorξ˜ƒhasξ˜ƒbeenξ˜ƒdropped.
The exclamation point within an equilateral triangle is
intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the
literature accompanying the product.
SAFETY WARNING
Doξ˜ƒnotξ˜ƒremoveξ˜ƒanyξ˜ƒcovers,ξ˜ƒloosenξ˜ƒanyξ˜ƒξ›„xingsξ˜ƒorξ˜ƒallowξ˜ƒitemsξ˜ƒtoξ˜ƒenterξ˜ƒanyξ˜ƒ
aperture.
SAFETY WARNING
Objectsξ˜ƒξ›„lledξ˜ƒwithξ˜ƒliquidsξ˜ƒshouldξ˜ƒnotξ˜ƒbeξ˜ƒplacedξ˜ƒonξ˜ƒthisξ˜ƒapparatus.
AVERTISSEMENT DE SECURITE
Neξ˜ƒretirezξ˜ƒpasξ˜ƒlesξ˜ƒcouvercles,ξ˜ƒneξ˜ƒdesserrezξ˜ƒpasξ˜ƒlesξ˜ƒξ›„xationsξ˜ƒetξ˜ƒneξ˜ƒlaissezξ˜ƒ
aucuneξ˜ƒpiΓ¨ceξ˜ƒs’introduireξ˜ƒdansξ˜ƒlesξ˜ƒouvertures.
AVERTISSEMENT DE SECURITE
Neξ˜ƒplacezξ˜ƒpasξ˜ƒd’objetsξ˜ƒcontenantξ˜ƒduξ˜ƒliquideξ˜ƒΓ ξ˜ƒproximitΓ©ξ˜ƒdeξ˜ƒl’appareil.
Introduction
Designedξ˜ƒandξ˜ƒengineeredξ˜ƒbyξ˜ƒTannoy,ξ˜ƒtheξ˜ƒVXNETξ˜ƒSeriesξ˜ƒcomprisesξ˜ƒaξ˜ƒrangeξ˜ƒofξ˜ƒpoweredξ˜ƒ(active)ξ˜ƒloudspeakersξ˜ƒforξ˜ƒdemandingξ˜ƒprofessionalξ˜ƒandξ˜ƒcommercialξ˜ƒ
soundξ˜ƒapplications.ξ˜ƒEachξ˜ƒincorporatesξ˜ƒacclaimedξ˜ƒDualξ˜ƒConcentricξ˜ƒdriverξ˜ƒtechnologyξ˜ƒinξ˜ƒtandemξ˜ƒwithξ˜ƒon-boardξ˜ƒpoweringξ˜ƒVNETξ˜ƒpowerξ˜ƒmodule.ξ˜ƒξ˜ƒ
Thisξ˜ƒQuickξ˜ƒStartξ˜ƒGuideξ˜ƒpresentsξ˜ƒonlyξ˜ƒtheξ˜ƒessentialξ˜ƒinformationξ˜ƒrequiredξ˜ƒtoξ˜ƒproperlyξ˜ƒunpack,ξ˜ƒconnectξ˜ƒandξ˜ƒplaceξ˜ƒtheξ˜ƒunitξ˜ƒinξ˜ƒoperation.ξ˜ƒPleaseξ˜ƒconsultξ˜ƒtheξ˜ƒfullξ˜ƒ
VXNETξ˜ƒSeriesξ˜ƒUserξ˜ƒManualξ˜ƒforξ˜ƒadditionalξ˜ƒinformationξ˜ƒonξ˜ƒsystemξ˜ƒconξ›„guration,ξ˜ƒlimitingξ˜ƒfunctions,ξ˜ƒriggingξ˜ƒandξ˜ƒsafetyξ˜ƒprocedures,ξ˜ƒandξ˜ƒwarrantyξ˜ƒcoverage.
Theξ˜ƒVXNETξ˜ƒUserξ˜ƒManualξ˜ƒisξ˜ƒavailableξ˜ƒatξ˜ƒwww.tannoypro.com.
Unpacking and Visual Checks
Everyξ˜ƒ Tannoyξ˜ƒ VXNETξ˜ƒ productξ˜ƒ isξ˜ƒ carefullyξ˜ƒ testedξ˜ƒ andξ˜ƒ
inspectedξ˜ƒbeforeξ˜ƒbeingξ˜ƒpackagedξ˜ƒandξ˜ƒleavingξ˜ƒtheξ˜ƒfactory.ξ˜ƒ
Afterξ˜ƒunpackingξ˜ƒyourξ˜ƒloudspeaker,ξ˜ƒpleaseξ˜ƒinspectξ˜ƒforξ˜ƒanyξ˜ƒ
exteriorξ˜ƒ physicalξ˜ƒ damage,ξ˜ƒ andξ˜ƒ saveξ˜ƒ theξ˜ƒ cartonξ˜ƒ andξ˜ƒ anyξ˜ƒ
relevantξ˜ƒ packagingξ˜ƒ materialsξ˜ƒ inξ˜ƒ caseξ˜ƒ theξ˜ƒ loudspeakerξ˜ƒ
againξ˜ƒ requiresξ˜ƒ packingξ˜ƒ andξ˜ƒ shipping.ξ˜ƒ Inξ˜ƒ theξ˜ƒ eventξ˜ƒ thatξ˜ƒ
damageξ˜ƒhasξ˜ƒbeenξ˜ƒsustainedξ˜ƒinξ˜ƒtransit,ξ˜ƒpleaseξ˜ƒnotifyξ˜ƒyourξ˜ƒ
dealerξ˜ƒimmediately.ξ˜ƒ
Rear Interface Panel
XLR FEMALE AUDIO INPUTξ˜ƒ -ξ˜ƒ Thisξ˜ƒ isξ˜ƒ aξ˜ƒ lockableξ˜ƒ XLRξ˜ƒ
lineξ˜ƒinputξ˜ƒsocketξ˜ƒforξ˜ƒconnectionξ˜ƒtoξ˜ƒtheξ˜ƒaudioξ˜ƒsource.ξ˜ƒFullyξ˜ƒ
balanced:ξ˜ƒpinξ˜ƒ2ξ˜ƒhotξ˜ƒ(+),ξ˜ƒpinξ˜ƒ3ξ˜ƒcoldξ˜ƒ(+),ξ˜ƒ&ξ˜ƒpinξ˜ƒ1ξ˜ƒground.ξ˜ƒ
XLR MALE AUDIO LINKξ˜ƒ -ξ˜ƒ Thisξ˜ƒ isξ˜ƒ aξ˜ƒ lockableξ˜ƒ XLRξ˜ƒ lineξ˜ƒ
outputξ˜ƒsocketξ˜ƒtoξ˜ƒlinkξ˜ƒadditionalξ˜ƒspeakers.ξ˜ƒFullyξ˜ƒbalanced:ξ˜ƒ
pinξ˜ƒ2ξ˜ƒhotξ˜ƒ(+),ξ˜ƒpinξ˜ƒ3ξ˜ƒcoldξ˜ƒ(+),ξ˜ƒ&ξ˜ƒpinξ˜ƒ1ξ˜ƒground.ξ˜ƒ
ROCKER POWER SWITCHξ˜ƒβ€“ξ˜ƒTurnsξ˜ƒACξ˜ƒpower
onξ˜ƒtoξ˜ƒtheξ˜ƒunitξ˜ƒ(100Vξ˜ƒβ€“ξ˜ƒ240V)
FUSE HOLDERξ˜ƒβ€“ξ˜ƒReplaceξ˜ƒonlyξ˜ƒwithξ˜ƒ10Aξ˜ƒ230V
anti-surgeξ˜ƒfuse.ξ˜ƒTannoyξ˜ƒpartξ˜ƒNumberξ˜ƒ3461ξ˜ƒ0919.
AC MAINS CONNECORξ˜ƒβ€“ξ˜ƒNeutrikξ˜ƒPowercon
mainsξ˜ƒconnectorξ˜ƒ(supplied)
USER DSP ON/OFF SWITCH
POWER LEDξ˜ƒβ€“ξ˜ƒBlueξ˜ƒLEDξ˜ƒindicatesξ˜ƒwhenξ˜ƒpower
hasξ˜ƒbeenξ˜ƒappliedξ˜ƒtoξ˜ƒtheξ˜ƒspeaker.
LIMIT/NETWORK FOUND LEDξ˜ƒβ€“ξ˜ƒAlsoξ˜ƒmounted
onξ˜ƒtheξ˜ƒfrontξ˜ƒofξ˜ƒtheξ˜ƒcabinet.ξ˜ƒThisξ˜ƒcanξ˜ƒbeξ˜ƒseen
clearlyξ˜ƒfromξ˜ƒbehindξ˜ƒtheξ˜ƒgrillξ˜ƒwhenξ˜ƒactivated.
SIGNAL PRESENT LED
System Configuration
Allξ˜ƒ loudspeakersξ˜ƒ inξ˜ƒ theξ˜ƒ VXNETξ˜ƒ rangeξ˜ƒ areξ˜ƒ integratedξ˜ƒ
designsξ˜ƒwhichξ˜ƒincludeξ˜ƒsystemξ˜ƒspeciξ›„cξ˜ƒEQξ˜ƒandξ˜ƒprotectionξ˜ƒ
circuitry,ξ˜ƒ withoutξ˜ƒ theξ˜ƒ needξ˜ƒ forξ˜ƒ externalξ˜ƒ ampliξ›„cation.ξ˜ƒ Forξ˜ƒ
roomξ˜ƒ equalization,ξ˜ƒ delayξ˜ƒ andξ˜ƒ otherξ˜ƒ commissioningξ˜ƒ orξ˜ƒ
setupξ˜ƒ functions,ξ˜ƒ weξ˜ƒ recommendξ˜ƒ youξ˜ƒ useξ˜ƒ aξ˜ƒ Vnetξ˜ƒ SC1ξ˜ƒ
orξ˜ƒ TDX1ξ˜ƒDigitalξ˜ƒ Controller.ξ˜ƒ Pleaseξ˜ƒreferξ˜ƒtoξ˜ƒtheξ˜ƒ fullξ˜ƒVXNETξ˜ƒ
Seriesξ˜ƒmanual.
AC Power Requirements
VXNETξ˜ƒ productsξ˜ƒ areξ˜ƒ equippedξ˜ƒ withξ˜ƒ Neutrikξ˜ƒ powerCONξ˜ƒ
mainsξ˜ƒconnectorsξ˜ƒwhichξ˜ƒmateξ˜ƒwithξ˜ƒtheξ˜ƒNeutrikξ˜ƒNAC3FCAξ˜ƒ
Cableξ˜ƒ connector,ξ˜ƒ providingξ˜ƒ quickξ˜ƒ lockξ˜ƒ withξ˜ƒ aξ˜ƒ securingξ˜ƒ
leverξ˜ƒatξ˜ƒpower-in.ξ˜ƒ
Thisξ˜ƒ ACξ˜ƒ mainsξ˜ƒ connectorξ˜ƒ isξ˜ƒ suppliedξ˜ƒ withξ˜ƒ eachξ˜ƒ VXNETξ˜ƒ
product.ξ˜ƒ
VXNETξ˜ƒ moduleξ˜ƒ inξ˜ƒ VXNETξ˜ƒ loudspeakersξ˜ƒ hasξ˜ƒ aξ˜ƒ universalξ˜ƒ
powerξ˜ƒ supply.ξ˜ƒ Itξ˜ƒ willξ˜ƒ operateξ˜ƒ onξ˜ƒ anyξ˜ƒ ACξ˜ƒ mainsξ˜ƒ supplyξ˜ƒ
fromξ˜ƒ100ξ˜ƒVξ˜ƒtoξ˜ƒ250ξ˜ƒVξ˜ƒ(+/-ξ˜ƒ10%)ξ˜ƒatξ˜ƒ50ξ˜ƒorξ˜ƒ60ξ˜ƒHz,ξ˜ƒalthoughξ˜ƒ
withξ˜ƒreducedξ˜ƒ powerξ˜ƒoutputξ˜ƒ capabilityξ˜ƒ atξ˜ƒ theξ˜ƒ lowξ˜ƒ voltageξ˜ƒ
extremes.ξ˜ƒ Thisξ˜ƒ allowsξ˜ƒ continuedξ˜ƒ operationξ˜ƒ evenξ˜ƒ whenξ˜ƒ
usingξ˜ƒ long,ξ˜ƒ thinξ˜ƒ powerξ˜ƒ cables,ξ˜ƒ orξ˜ƒ whenξ˜ƒ poweredξ˜ƒ fromξ˜ƒ
portableξ˜ƒgeneratorsξ˜ƒthatξ˜ƒareξ˜ƒunableξ˜ƒtoξ˜ƒmaintainξ˜ƒfullξ˜ƒnominalξ˜ƒ
voltage.
Cooling
Doξ˜ƒ notξ˜ƒinstallξ˜ƒ thisξ˜ƒ equipmentξ˜ƒ inξ˜ƒ anξ˜ƒ enclosedξ˜ƒ space.ξ˜ƒ Doξ˜ƒ
notξ˜ƒlimitξ˜ƒfreeξ˜ƒventilationξ˜ƒandξ˜ƒmovementξ˜ƒofξ˜ƒairξ˜ƒaroundξ˜ƒtheξ˜ƒ
backξ˜ƒ panel.ξ˜ƒ Ensureξ˜ƒ thatξ˜ƒ thereξ˜ƒ isξ˜ƒ atξ˜ƒ leastξ˜ƒ 100ξ˜ƒ mmξ˜ƒ (4”)ξ˜ƒ
ofξ˜ƒ spaceξ˜ƒ aroundξ˜ƒ allξ˜ƒ sidesξ˜ƒ ofξ˜ƒ theξ˜ƒ productξ˜ƒ forξ˜ƒ ventilation.ξ˜ƒ
VXNETξ˜ƒ productsξ˜ƒ doξ˜ƒ notξ˜ƒ haveξ˜ƒ coolingξ˜ƒ fans;ξ˜ƒ theξ˜ƒ highlyξ˜ƒ
efξ›„cientξ˜ƒ switchξ˜ƒ modeξ˜ƒ powerξ˜ƒ supplyξ˜ƒ andξ˜ƒ proprietaryξ˜ƒξ˜ƒ
Classξ˜ƒDξ˜ƒoutputξ˜ƒstageξ˜ƒhaveξ˜ƒlowξ˜ƒcurrentξ˜ƒdrawξ˜ƒandξ˜ƒthereforeξ˜ƒ
requireξ˜ƒonlyξ˜ƒ theξ˜ƒ convectionξ˜ƒ coolingξ˜ƒprovidedξ˜ƒbyξ˜ƒ theξ˜ƒ rearξ˜ƒ
panelξ˜ƒheatξ˜ƒsink.

Especificaciones del producto

Marca: Tannoy
CategorΓ­a: Vocero
Modelo: VXNET 12Q
ColocaciΓ³n del dispositivo: Ingebouwd
Color del producto: Zwart
Peso.: 7000 g
Ancho: 583 mm
Profundidad: 513 mm
Altura: 43 mm
Tipo de material (arriba): Keramisch
Potencia quemador/zona de cocciΓ³n 2: 1200 W
Potencia quemador/zona de cocciΓ³n 3: 1200 W
Potencia quemador/zona de cocciΓ³n 1: 2000 W
NΓΊmero de quemadores/zonas de cocciΓ³n: 4 zone(s)
tipo de placa: Inductiekookplaat zones
Quemador/zona de cocciΓ³n tipo 1: Regulier
Quemador/zona de cocciΓ³n tipo 2: Sudderen
Tipo de quemador/zona de cocciΓ³n 3: Sudderen
NΓΊmero de zonas de cocciΓ³n electrΓ³nicas: 4 zone(s)
Carga conectada (elΓ©ctrica): 6600 W
Ancho del compartimento de instalaciΓ³n: 560 mm
Altura del compartimento de instalaciΓ³n: 43 mm
Profundidad del compartimento de instalaciΓ³n (min): 490 mm
Tipo de quemador/zona de cocciΓ³n 4: Groot
Potencia quemador/zona de cocciΓ³n 4: 2200 W
Fuente de alimentaciΓ³n quemador/zona de cocciΓ³n 1: Electrisch
Fuente de alimentaciΓ³n quemador/zona de cocciΓ³n 2: Electrisch
Fuente de alimentaciΓ³n quemador/zona de cocciΓ³n 3: Electrisch
Fuente de alimentaciΓ³n del quemador/zona de cocciΓ³n 4: Electrisch
Profundidad del compartimento de instalaciΓ³n (mΓ‘x.): 500 mm
PosiciΓ³n del quemador/zona de cocciΓ³n 1: Links achter
DiΓ‘metro quemador/zona de cocciΓ³n 1: 180 mm
PosiciΓ³n quemador/zona de cocciΓ³n 2: Links voor
Quemador/zona de cocciΓ³n diΓ‘metro 2: 145 mm
PosiciΓ³n quemador/zona de cocciΓ³n 3: Rechts achter
Quemador/zona de cocciΓ³n diΓ‘metro 3: 145 mm
PosiciΓ³n del quemador/zona de cocciΓ³n 4: Rechts voor
Quemador/zona de cocciΓ³n diΓ‘metro 4: 210 mm
Forma zona de cocciΓ³n 1: Rond
Forma zona de cocciΓ³n 2: Rond
Forma zona de cocciΓ³n 3: Rond
Forma zona de cocciΓ³n 4: Rond
voltaje-de-entrada-de-CA: 220-240 V
Frecuencia-de-entrada-de-CA: 50 - 60 Hz

ΒΏNecesitas ayuda?

Si necesitas ayuda con Tannoy VXNET 12Q haz una pregunta a continuaciΓ³n y otros usuarios te responderΓ‘n




Vocero Tannoy Manuales

Vocero Manuales

Últimos Vocero Manuales