Tascam IF-CB/DM Manual de Usario

Lee a continuación 📖 el manual en español para Tascam IF-CB/DM (4 páginas) en la categoría No categorizado. Esta guía fue útil para 7 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/4
IF-CB/DM
CobraNet Interface Card
D01106320A
Introduction
Thank you very much for purchasing the TASCAM IF-CB/
DM CobraNet™ Interface Card for TASCAM DM-3200
and DM-4800 mixers.
This Interface Card allows a TASCAM DM-3200/DM-4800
to be connected to a CobraNet digital audio network and to
send and receive up to 32 channels (16 inputs/16 outputs)
of uncompressed digital audio signals with a sampling
frequency of 48 kHz.
Before using the unit, please take time to read this manual
thoroughly to ensure you understand how to properly set up
and connect the unit, as well as the operation of its many
useful and convenient functions. After you have nished
reading this manual, please keep it in a safe place for future
reference.
You can also download the Owners Manual from the
TASCAM web site (http://www.tascam.com).
After reading this manual, we recommend that you visit
the CobraNet website below before using this card. This
site provides valuable information, including an overview
of CobraNet, explanations of technologies, application
methods, examples of use, and tool downloads.
http://www.cobranet.info/
Features
Transmission of up to 32 channels (16 inputs/16 outputs)
of audio
Compatible with 24 bit quantization and 48 kHz
sampling frequency
Trademarks
TASCAM is a trademark of TEAC Corporation,
registered in the U.S. and other countries.
Microsoft and Windows are either registered trademarks
or trademarks of Microsoft Corporation in the United
States and/or other countries.
CobraNet is a trademark of Cirrus Logic, Inc.
Other company names, product names and logos in this
document are the trademarks or registered trademarks of
their respective owners.
Product components
The included items are listed below.
Take care when opening the package not to damage the
items. Keep the package materials for transportation in the
future.
Please contact the store where you purchased this unit if any
of these items are missing or have been damaged during
transportation.
Main unit
.........................................................................1
Attachment screws
..........................................................5
Owners Manual (this document)
....................................1
Names and functions of parts
1SECONDARY (RJ-45 connector): connector for the
secondary cable
2 PRIMARY (RJ-45 connector): connector for the primary
cable
3 Green indicator
Light or blink slowly when a network cable is
connected correctly.
Blink rapidly when data is being transmitted properly
over the network.
4Orange indicator
Blink when functioning as the conductor (clock
master).
Light when power is properly supplied.
Primary and Secondary both blink when an
irregularity occurs on the network.
DM-3200/DM-4800 software
version
In order to use the IF-CB/DM card, the DM-4800/DM-3200
must use software version 1.70 or later. The mixer cannot
recognize the IF-CB/DM card when using earlier versions.
Check the TASCAM website (http://www.tascam.com/) for
the latest DM-4800/DM-3200 software and download the
TFI update le.
Install TMCompanion, which is included on the CD-ROM
included with the DM-4800/DM-3200, on the computer
that you are using. Launch TMCompanion and use the TFI
update le to upgrade the software version used by the
DM-4800/DM-3200.
Installing the IF-CB/DM
NOTE
DM-3200: Install the IF-CB/DM in mixer slot 1. It will
not function in slot 2.
DM-4800: Install the IF-CB/DM in mixer slot 1 or 3. It
will not function in slot 2 or 4.
Turn the mixer power OFF before beginning
installation.
1 Remove the five screws from the cover panel of the
slot where you want to install the IF-CB/DM card
(slot 1 on a DM-3200, slot 1 or 3 on a DM-4800), and
then remove the panel. (If that slot already contains
a card, remove the card.)
IF-CB/DM
CobraNet Interface Card
2 Insert the IF-CB/DM card into the slot. Insert the
card completely, aligning its edges with the white
guidelines on the inside of the slot. Push the card
in until it clicks into place and its backplate is even
with the back of the mixer. Do not, however, push the
card too hard. If you are having difficulty inserting it
properly, pull it out once and try again.
3 Use the five screws that you removed earlier or the
five screws included with this card to fix the card in
place.
4 Turn the mixer’s power ON, and open the DIGITAL
screen (with the ALT key indicator lit, press screen
mode selection key 2). Select the SLOT tab (SLOT
1-2 or SLOT 3-4 for the DM-4800), and confirm that
the unit recognizes the installed card. If a “No Card”
message appears, the card might not have been
inserted properly or the screws might not be tight
enough.
Connecting with other CobraNet
devices
After installing the IF-CB/DM card into a DM-4800/
DM-3200 mixer, connect it to other CobraNet devices
through a switching hub.
For the LAN cables, use straight, shielded, twisted pair
cables that are category 5 or higher.
For the switching hub, use a device recommended on the
CobraNet web site.
Set up the CobraNet network so that it is completely
independent from other networks.
Transmission distance
The length of cables that can be used depends on the quality
of the cables and the various other devices located between
the transmitting and receiving devices.
The maximum length that can be used with category 5
cables is 100 m. If transmission over a greater distance
is necessary, multimode optical ber cables can be used
(maximum distance of 2 km).
Mixer control screen
The IF-CB/DM setting screen shown below appears the
same for both DM-3200 and DM-4800 mixers. Press the
ALT key and screen mode selection key 2 to open the
DIGITAL screen, and select the SLOT tab (SLOT 1-2 or
SLOT 3-4 for the DM-4800).
STATUS
ª
This section shows information about the IF-CB/DM card
status.
CLOCK:
This shows whether or not the clock is synchronized and
whether the unit (including the mixer) is a performer or the
conductor.
UNLOCKED
:
This unit is not synchronized with the clock.
LOCKED,
PERFORMER
:
This unit is a performer and is synchronized with the
clock.
LOCKED,
CONDUCTOR
:
This unit is the conductor and is synchronized with the
clock.
NOTE
When this unit is a performer set the clock source for
the mixer to the slot where the IF-CB/DM is installed.
When this unit is the conductor, other devices
connected to the same Cobranet as this unit are
synchronized to its clock. We recommend that you set
the clock source for the mixer to the slot where the
IF-CB/DM is installed, but if you select a different one,
use Cobranet Discovery to set it to a device with high
priority as a conductor.
Use Cobranet Discovery, which is a separate appli-
cation, to set whether this unit is a performer or the
conductor.
CURRENT:
That shows whether the installed IF-CB/DM card is
currently operating on the PRIMARY or SECONDARY
network connection.
PORT P:
This shows the status of the PRIMARY PORT.
PORT S:
This shows the status of the SECONDARY PORT.
NETWORK
ª
This section shows information about the status of the
network.
IP ADDR:
This shows the IP address of the installed IF-CB/DM card.
2 TASCAM IF-CB/DM
IF-CB/DM
CobraNet Interface Card
DUAL LINK:
This shows the network connection method.
Prefer
Primary
(default setting):
The Primary network has priority. If the Primary network
connection is lost, the mixer automatically switches to
the Secondary network, and reconnects to the Primary
network when it recovers.
Always
Primary
:
Only uses the Primary network.
Always
Secondary
:
Only uses the Secondary network.
Auto
Switch
:
Uses the Primary network at start-up. If the Primary
network connection is lost, it switches to the Secondary
network, and continues using the Secondary network
even if the Primary network recovers. If the Secondary
network connection is lost, it switches back to the
Primary network.
NAME:
This shows the name of the installed IF-CB/DM card.
LATENCY:
This shows the current latency setting.
BITS:
This shows the current bit-rate setting.
SYSTEM
ª
This section shows information about the system.
F/W VER:
This shows the IF-CB/DM rmware version.
ERRORS:
This shows the number of errors that have occurred.
LOAD:
This shows the network load.
DM-3200/4800 settings
Setting the clock
1 Press the PROJECT key to open the CLOCK
screen where you can set the clock source. (See the
“Clock setting” section of chapter 3 of the DM-3200/
DM-4800 User’s Manual.)
2 Set the Fs MODE to 48k, and in the CLOCK SE-
LECT area, select the SLOT where the IF-CB/DM
card is installed. This enables stable operation even
when switching between conductor and performer.
Input settings (input routing)
Make input settings on the INPUT page of the DM-3200/
DM-4800 ROUTING screen.
DM-3200 INPUT page
1 Use the POD 4 knob to select the input source group.
Input source groups are shown in the SOURCE SE-
LECT list at the lower right of the screen.
2 Use the POD 3 knob to select the input source rout-
ing destination layer. Routing destination groups are
shown in the LAYER SELECT list at the upper right
of the screen.
3 Use the cursor keys to select the source field, and use
the JOG/DATA dial to select the input source.
4 After making the selection, press the ENTER key to
confirm it.
Output settings (output routing)
Make output settings using the OUTPUT SLOT page of the
DM-3200/DM-4800 ROUTING screen.
DM-3200 OUTPUT SLOT page
TASCAM IF-CB/DM 3

Especificaciones del producto

Marca: Tascam
Categoría: No categorizado
Modelo: IF-CB/DM

¿Necesitas ayuda?

Si necesitas ayuda con Tascam IF-CB/DM haz una pregunta a continuación y otros usuarios te responderán




No categorizado Tascam Manuales

No categorizado Manuales

Últimos No categorizado Manuales