5296652
Digital Folding K Type Thermocouple with Replaceable Probe-
Thank you for purchasing a Taylor® Type Thermocouple Please read this Digital Folding K- .
instruction manual carefully before use. Keep these instructions handy for future reference.
Please remember to keep the unit away from children and do not use it for safety related
applications.
THERMOCOUPLE PROBE REPLACEMENT
To replace the K-type thermocouple probe, unfold the probe to open position. Turn screw
cap counterclockwise to loosen and remove. Gently pull probe in an outward direction to
remove. Insert new probe, aligning the "+" and " " polarity symbols. Replace screw cap, -
turn clockwise to tighten.
DIGITAL FOLDING THERMOCOUPLE PROBE FUNCTION
To turn the unit on, unfold the probe to an open position (between a 45° 180° degree angle). -
A motion sensor within the unit will re illuminate the back light, pick up or gently shake the - -
thermometer to activate. The unit will continuously display temperatures for up to 10
minutes. After that, the unit will automatically shut off to preserve battery life. Or, to turn off
manually, fold the probe to a closed position.
1. Placing stress on the probe may cause breakage.
2. After measuring high temperatures, the probe may remain HOT for a while. Allow the
p robe to cool before touching.
3. Use caution while handling the probe to avoid injury. Keep probe out of reach of
children.
The probe may be damaged if used to measure a temperature that exceeds the
specification of the measurement temperature range.
To avoid electric shock and thermometer damage, do not measure a live circuit where
the voltage exceeds 24V AC RMS or 60V CD with the thermocouple probe.
°F C OR ° MODE
To switch between ‘°F’ and ‘°C’, unfold probe to open position, rotate unit left to right three
times in a row. Or, loosen screws on the battery compartment cover, remove the cover and
press ºF/ºC button
BACKLIGHT FEATURE
The backlight will activate for 15 seconds when the unit is in the open position.
LCD ERROR MESSAGES
The thermocouple incorporates visual diagnostic messages as follows:
‘Hi’ ’Lo’ or
is displayed when the temperature being measured is outside of
the measurement range.
‘bAt’
indicates a low battery warning. Replace both batteries at the same
time.
‘
"Er3" is displayed when the entire unit has been exposed to ambient
temperature below 32ºF (0ºC) or above 122ºF (50ºC). Allow
approximately 30 minutes for the unit to stabilize back to working room
temperature.
BATTERY INSTALLATION
The thermocou operates ple on 2 AAA batteries (included).
1. Remove any plastic wrap from the batteries before proceeding.
2. Loosen the screws on the battery compartment cover on the back of the
thermocouple . and remove the cover
3. Install 2 “AAA” batteries into the battery compartment according to the “+” and “-”
polarity symbols in the battery compartment.
4. Replace the battery compartment cover s. and tighten the screw
CAUTION: When batteries of different brand or type are used together, or new and old
batteries are used discharged due to together, some batteries may be over-
difference of voltage or capacity. This can result in venting, leakage, and rupture
and may cause personal injury.

NOTE: Please recycle or dispose of batteries correctly per local regulations.
WARNING: Batteries may pose a choking hazard. Do not let children hand batteries. Keep
batteries away from children. If swallowed, seek medical attention immediately
PRECAUTION: Do not dispose of the unit or batteries in fire, as the batteries inside this unit
may explode or leak. Remove the batteries if the product will not be used for along period of
time. Remove used batteries promptly. Clean the battery contacts and also those of the
device prior to battery installation.
STORAGE & CLEANING
Take care eaning the using only a soft cloth or cotton swab with when cl thermocouple,
water or medical alcohol, allow the o not and thermocouple . Dto fully dry before using it
submerge any part . The of the thermocouple thermocouple should be stored at room
temperature betw een -4 to +140 -°F ( 20 to +60 ). °C
SPECIFICATIONS
Item
Digital Folding K- Type Thermocouple
Probe Measurement Range
-40°F to 500°F (- 40°C to 260°C)
Operating Range
32 to122°F (0 to 50°C)
Resolution
0.1°F (0.1°C)
Probe Accuracy
±1% of reading or 1°F (1°C)
Battery Life
Typically 40 hours, minimum 30 hours continuous use
Batteries
2 AAA batteries
Display
LCD 1.57x0.75 inch (40x19mm)
Dimensions
6.42x1.93x1.06 inch (163x49x26.9mm)
Probe length
3.3” (8.382cm)
IPX7 Waterproof Rating
IPX7 when the battery door is properly closed and the
probe is properly attached
EMC/RFI
Readings may be affected if the unit is operated within a radio frequency electromagnetic
field strength of approximately 3 volts per meter, but the performance of the instrument will
not be permanently affected.
DO NOT keep the unit too close to objects that continuously generate high heat (such as
a hot plate) for long periods of time. This may cause the unit to overheat.
CARE AND PRECAUTIONS
1. Always read instructions thoroughly to ensure that you have the full benefit of all
the unit's eatures.f
2. Keep thermometer and probe out of reach of all children.
3. DO NOT immerse unit in water, as doing so will cause damage to internal components
and void the warranty. If you spill liquid on it, dry it immediately with a soft, lint -free
cloth. The unit is not dishwasher safe. Damage will void warranty.
4. DO NOT clean the unit with an abrasive or corrosive material. This may scratch the
plastic parts and corrode the electronic circuits.
5. DO NOT subject the units to excessive force, shock, dust, temperature or humidity.
This may result in malfunction, shorter electronic life span, damaged battery and
distorted parts.
6. DO NOT operate or store the unit in high temperature or humidity conditions. The
heat or moisture may interfere with the unit’s internal components. Store the unit at
temperatures between °C).-4 0 – 0and +14 °F ( 20 and +6
7. DO NOT tamper with the unit's internal components. Doing so will invalidate the
warranty on the unit and may cause damage. The unit contains no user-serviceable
parts.
8. This unit operates on 2 AAA batteries. Always purchase the correct size and grade of
battery most suitable for the intended use. Always replace both batteries at the
same time; do not combine old and new batteries. Do not mix Alkaline, carbon-zinc
(standard) or N - ickel Cadmium (rechargeable) batteries.
Two Year Limited Warranty
Taylor warrants this product to be free from defects in materials or workmanship for two (2 s ) year
(excluding batteries) for the original pur from date of original purchase. It does not cover chaser
damages or wear resulting from accident, misuse, abuse, commercial use, or unauthorized adjustment
and/or repair. If service is required, do not return to distributor. For service, call between 7:30 AM and
4:30 PM, Mountain Standard Time, Monday through Friday. To assist us in servic you, please have the ing
model number and date of purchase available. Should this product require service (or replacement at
our option), please pack the item carefully and return it prepaid, along with receipt showing date of
purchase and a note explaining reason for return to:
Taylor, a division of Lifetime Brands, Inc.
2220 Entrada del Sol, Suite A
Las Cruces, New Mexico 88001
Customer Service Phone: 1- - - 800 225 4834
Cust -575-526- omer Service Fax: 1 4347
www.taylorusa.com
There are no expressed warranties except as listed above. This warranty gives you specific legal rights,
and you may have other rights which vary from state to state.
For additional product information, or warranty information outside the USA, please contact us through
www.taylorusa.com.
© 2022 Taylor, a division of Lifetime Brands, Inc. All rights reserved.
Made to our exact specifications in China.
5296652 8.22 WC
Especificaciones del producto
Marca: | Taylor |
Categoría: | termómetro |
Modelo: | 5296652 |
Peso.: | 900 g |
Ancho: | 300 mm |
Profundidad: | 130 mm |
Altura: | 130 mm |
Tipo de fuente de energía: | Niet ondersteund |
Uso correcto: | Universeel |
Material: | PVC |
Manejas): | Nee |
¿Necesitas ayuda?
Si necesitas ayuda con Taylor 5296652 haz una pregunta a continuación y otros usuarios te responderán
termómetro Taylor Manuales

6 Septiembre 2024

6 Septiembre 2024

6 Septiembre 2024

6 Septiembre 2024

6 Septiembre 2024

6 Septiembre 2024

6 Septiembre 2024

6 Septiembre 2024

6 Septiembre 2024

6 Septiembre 2024
termómetro Manuales
- termómetro Braun
- termómetro Philips
- termómetro Fysic
- termómetro Inventum
- termómetro Quigg
- termómetro Topcom
- termómetro AnD
- termómetro Amprobe
- termómetro Arendo
- termómetro ATN
- termómetro Aponorm
- termómetro Bartscher
- termómetro Kruidvat
- termómetro Orbegozo
- termómetro Omega
- termómetro Telefunken
- termómetro Thomson
- termómetro Innoliving
- termómetro Tristar
- termómetro Pyle
- termómetro SereneLife
- termómetro Beurer
- termómetro Melissa
- termómetro Emerio
- termómetro Clatronic
- termómetro Sencor
- termómetro Lanaform
- termómetro Cuisinart
- termómetro Medisana
- termómetro Milwaukee
- termómetro Elro
- termómetro EMOS
- termómetro Extech
- termómetro Easypix
- termómetro Beper
- termómetro Omron
- termómetro Citizen
- termómetro Hama
- termómetro Cresta
- termómetro Voltcraft
- termómetro Terraillon
- termómetro Velleman
- termómetro Vemer
- termómetro La Crosse Technology
- termómetro Weber
- termómetro Marquant
- termómetro Perel
- termómetro Kyoritsu
- termómetro Homedics
- termómetro Sanitas
- termómetro AcuRite
- termómetro Auriol
- termómetro Technoline
- termómetro Olympia
- termómetro Cotech
- termómetro Rossmax
- termómetro Vicks
- termómetro Microlife
- termómetro Welch Allyn
- termómetro Testboy
- termómetro Salter
- termómetro Trotec
- termómetro BabyOno
- termómetro Laica
- termómetro Safety 1st
- termómetro TFA
- termómetro Respekta
- termómetro Boso
- termómetro Clas Ohlson
- termómetro Mabis
- termómetro Owon
- termómetro Luvion
- termómetro Irox
- termómetro Konig
- termómetro Reer
- termómetro Miniland
- termómetro Fluke
- termómetro Leifheit
- termómetro Etekcity
- termómetro Ecomed
- termómetro Laserliner
- termómetro Comark
- termómetro Fora
- termómetro Testo
- termómetro Elta
- termómetro Zeiss
- termómetro Beaba
- termómetro Eurochron
- termómetro Grado
- termómetro La Crosse
- termómetro Medel
- termómetro Geratherm
- termómetro Truelife
- termómetro Turbotronic
- termómetro Pacom
- termómetro Westfalia
- termómetro Bioland
- termómetro Global Tronics
- termómetro Oregon Scientific
- termómetro Levita
- termómetro Kerbl
- termómetro Okoia
- termómetro Scala
- termómetro Uebe
- termómetro Duronic
- termómetro Dittmann
- termómetro TFA Dostmann
- termómetro Greisinger
- termómetro Beha-Amprobe
- termómetro CDN
- termómetro Emga
- termómetro Hartmann
- termómetro VDH
- termómetro ZKTeco
- termómetro Esperanza
- termómetro Pancontrol
- termómetro Uni-T
- termómetro General
- termómetro Ebro
- termómetro Arya
- termómetro RK Technology
- termómetro Mobi
- termómetro TQC
- termómetro Bintoi
- termómetro Veroval
- termómetro Jumper
- termómetro PeakTech
- termómetro Elem6
- termómetro Thermoval
- termómetro Pasha
- termómetro Innovo
- termómetro Delta Ohm
- termómetro Guide
- termómetro InfiRay
- termómetro Chauvin Arnoux
- termómetro BeSafe
- termómetro PCE Instruments
- termómetro Joy-it
- termómetro Techno Line
- termómetro Klein Tools
- termómetro Knikker
- termómetro FlinQ
- termómetro AvaTemp
- termómetro EasyLife
- termómetro Alter
- termómetro TensCare
- termómetro Yummly
- termómetro Eks
- termómetro Gima
- termómetro Aspen
- termómetro Salva Tec
- termómetro Radiant
- termómetro Kuchenprofi
- termómetro WBTT
- termómetro Welby
- termómetro Prologue
- termómetro A&D
- termómetro ClimeMET
- termómetro Bearware
Últimos termómetro Manuales

27 Octubre 2024

22 Octubre 2024

22 Octubre 2024

22 Octubre 2024

22 Octubre 2024

22 Octubre 2024

20 Octubre 2024

17 Octubre 2024

16 Octubre 2024

16 Octubre 2024