TP Link PSM150-AC Manual de Usario

Lee a continuación 📖 el manual en español para TP Link PSM150-AC (3 páginas) en la categoría No categorizado. Esta guía fue útil para 2 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/3
Overview
1
The PSM150-AC is an AC-input and DC-output power supply module. It can
convert the input voltage to 12 V with the maximum output power of 150 W.
PSM150-AC
Fastening Screw AC Power Input JackPower Supply Module Handle
The PSM150-DC is a DC-input and DC-output power supply module. It can
convert the input voltage to 12 V with the maximum output power of 150 W.
PSM150-DC
Fastening Screw DC Power Input JackPower Supply Module Handle
LED and Feature Explanation
2
When the power module reverts to the protected state, its recovery features
are as follows.
Note:
1. The failure of output over-voltage or over-current may cause the power LED
to ash.
2. Hot-swap control function will be checked when the module is powered on
but has not been inserted into the device. If the Fault LED is on under this
condition, please do not insert the module into the device, otherwise the power
supply module or the powered devices may be damaged.
3. There is still power supply when a fan fault occurs, do not touch the module.
LED Status Description
Power On Power supply module is powered on and running well, but
not supplying power to the device.
Power On
PS OK On Power supply module is powered on and running well, and
supplying power to the device.
Power On
Fault On
The circuit has faults, such as output over-voltage
1, output
under-voltage, output over-current
1, output short circuit,
hot-swap control failure2 or fan fault3.
Power o or power supply fault.
Feature Description
Protection Function
Redundant Backup
Hot Swappable
Protection
Function Protective Action Recovery Characteristics
Note: When the power supply module is locked or auto-retry continually, you
can try the following steps to restore the device.
1. Disconnect the power cord from the external power supply system.
2. Disconnect the power cord from the power supply module.
3. Remove the power supply module from the device.
4. Insert the power supply module again.
5. Connect the power cord to the power supply module again.
6. Connect the other end of the power cord to the external supply system.
3Specication
PSM150-AC PSM150-DC
Power
Input
100 V–240 V~ 50/60 Hz
2.5A
-48 – -60 V 6 A
Output
Voltage 12 VDC 12 VDC
Output
Current 12.5 A (Maximum) 12.5 A (Maximum)
Output
Power 150 W (Maximum) 150 W (Maximum)
Temperature
Operation : 0°C to 50°C (32 to 122°F)
Storage: -40°C to 70°C (-40 to 158°F)
Humidity
Operation : 10% to 90% RH Non-condensing
Storage: 5% to 90% RH Non-condensing
Sea level to 4000 m
Supports dual power modules combining in parallel
to implement 1+1 redundancy for uninterruptible
power supply.
Includes protection of output over-voltage, output
under-voltage, output short circuit and output
over-current.
In the case of 1+1 redundant power supply system,
the power supply module can be plugged out or
plugged in without shutting down the OLT.
Output
over-voltage &
under-voltage
protection
Power supply
module locked and
cut-o supply
The power supply module can not
recover automatically.
Output short
circuit
protection
Power supply
module locked and
cut-o supply
Power supply module reverts into
the auto-retry mode. It can recover
automatically when the fault is
cleared.
Output
over-current
protection
Power supply
module locked and
cut-o supply
Power supply module reverts into
the auto-retry mode. It can recover
automatically when the fault is
cleared.
Mains
Transient
Voltage
/2500 Vpeak (Maximum)1
Installation
4
Install the Power Supply Module
Tools for Installation
• Straight screwdriver • Philips screwdriver • ESD-preventive wrist strap
Safety Information
To avoid damage to the power supply module and the equipment and bodily
injury, the product can only be used by instructed persons.
Please observe the following notes:
• When you install and remove the power supply module, please wear an
ESD-preventive wrist strap, and make sure that it has good skin contact and is
well grounded.
• Before installing the power supply module, make sure that the voltage of
external power supply system is the same with the voltage marked in the power
supply module, and the output voltage of the power supply module is the same
with the required voltage of the powered devices in order to prevent damaging
the power supply module or the powered devices.
• Do not touch any exposed wires or terminals to avoid bodily injury.
• Do not place the power module in a humid place or let the liquid into the
power supply module.
• If there is a failure inside the module, please contact service personnel,
instead of opening the housing of the module.
• For PSM150-DC, the rating of the external overcurrent protective device shall
not exceed 16 A.
• For PSM150-DC, an all-pole mains switch in accordance with EN 62368-1
2014 Annex L shall be incorporated in the electrical installation of the building.
And the disconnect device shall have a contact separation of at least 1.5 mm.
• The equipment must not be used in locations where children are likely to be
present.
For simplicity, we will take PSM150-AC for example.
Note:
1.The product can be powered by a DC power source such as accumulator cell
and a power supply server. The DC power supply should comply with EN
62368-1 2014 clause 5.4.2.3.2.3, and the transient voltage shall be no more
than 2500 Vpeak
.
1. Wear an ESD-preventive wrist strap, and make sure that it has good skin
contact and is well grounded.
2. Grip the handle of the module with one hand, and hold the bottom of the
module using your other hand. Gently push the module in along the slot guide
rail.
3. Tighten the captive screws with a Phillips screwdriver to x the power supply
module in place.
PSM150-AC:
Connect the Power Cord and Connect to the Ground
After the power supply module is installed on the device, please plug the
female connector of the provided power cord into the power socket of the
device, and the male connector into a power outlet. Meanwhile, it will connect
to the ground via the power supply.
Altitude
Installation Guide
Power Supply Module
7106509289 REV3.0.0 © 2021 TP-Link
Remove the Power Supply Module
1. Wear an ESD-preventive wrist strap, and make sure that it has good skin
contact and is well grounded.
2. Remove the power cord from the external power supply system and the
power module.
3. Use a Phillips screwdriver to loosen the captive screws at both sides of the
power supply module until all spring pressure is released.
4. Pull the handle with one hand along the guide rails, and hold the bottom of
the module using your other hand, until it completely comes out of the chassis.
Note:
When installing or removing a power supply module, pay attention to the
following points:
• Make sure that the power supply module is set correctly in the operation of
installation.
• Do not use too much force in the installation. If resistance is encountered or
positions of the power supply module appear larger during installation, you
must rst remove the module and then reinstall the module.
• If screws cannot be tightened, it may be due to the power supply module is
not installed properly. Please check carefully.
• In order to better protect the power supply module during removal, it is
recommended that you package it in an antistatic bag.
Safety Information
Keep the device away from water, re, humidity or hot environments.
Do not attempt to disassemble, repair, or modify the device. If you
need service, please contact us.
Avoid using this product during an electrical storm. There may be a
remote risk of electric shock from lightning.
EU Declaration of Conformity
TP-Link hereby declares that the device is in compliance with the
essential requirements and other relevant provisions of directives
2014/30/EU, 2014/35/EU, 2009/125/EC, 2011/65/EU and (EU)2015/863.
The original EU declaration of conformity may be found at
https://www.tp-link.com/en/support/ce/
UK Declaration of Conformity
TP-Link hereby declares that the device is in compliance with the
essential requirements and other relevant provisions of the
Electromagnetic Compatibility Regulations 2016 and Electrical
Equipment (Safety) Regulations 2016.
The original UK Declaration of Conformity may be found at
https://www.tp-link.com/support/ukca
PSM150-DC:
Connect the Power Cord and Connect to the Ground
For technical support, the user guide and other information,
please visit https://www.tp-link.com/support, or simply
scan the QR code.
If you have any suggestions or needs on the product
guides, welcome to email techwriter@tp-link.com.cn.
To ask questions, find answers, and communicate with TP-Link users
or engineers, please visit https://community.tp-link.com to join
TP-Link Community.
• Equipotential bonding
Equipotential bonding is the practice of intentionally electrically connecting all
earthed systems to the same grounding grid or connecting the grounding
grids of all the earthed systems together through the ground or overground
metal so as to create an earthed equipotential zone. When lightning occurs, the
high voltage produced by lightning current in all systems will meanwhile exist in
their ground cables, and thus all ground cables have the same electrical
potential and basically eliminate the electric strikes between the systems. The
gure below illustrates how to practice equipotential bonding in a network.
Grounding Terminal Equipotential Bonding Cable
Grounding Bar Ground Cable (18-14 AWG)
• Use the grounding bar
If the device is installed in the Equipment Room, where a grounding bar is
available, it is recommended to connect the device to the grounding bar with
an 18-14 AWG ground cable as shown in the following gure.
Device (Rear Panel)
Ground Cable (18-14 AWG)
Grounding Terminal
Grounding Bar
1. Connect the power cord
It is recommended to use an 18-14 AWG power cord to connect the power
supply equipment and PSM150-DC, and make sure that the connection is
reliable. When connecting, make sure that the positive and negative poles of
the power supply equipment correspond to the positive and negative poles of
the PSM150-DC.
2. Connect to the ground
In dierent environments, the device may be grounded dierently. The
following will instruct you to connect the device to the ground in two ways.
Note that the protective earthing terminal must be connected to the installation
protective earthing conductor.
CAN ICES-3 (A)/NMB-3(A)
Industry Canada Statement
この装置は、クラスA情報技術装置です。この装置を家庭環境で使
用すると電波妨害を引き起こすことがあります。この場合には使用
者が適切な対策を講ずるよう要求されることがあります。
VCCI-A
This is a class A product. In a domestic environment, this product may cause
radio interference, in which case the user may be required to take adequate
measures.
CE Mark Warning
FCC compliance information statement
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user will
be required to correct the interference at his own expense.
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, including interference
that may cause undesired operation.
Any changes or modications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
Product Name: Power Supply Module
Model Number: PSM150-AC/PSM150-DC
Responsible party:
TP-Link USA Corporation, d/b/a TP-Link North America, Inc.
Address: 10 Mauchly, Irvine, CA 92618
Website: https://www.tp-link.com/us/
Tel: +1 626 333 0234
Fax: +1 909 527 6803
E-mail: sales.usa@tp-link.com
We, TP-Link USA Corporation, has determined that the equipment shown as
above has been shown to comply with the applicable technical standards, FCC
part 15. There is no unauthorized change is made in the equipment and the
equipment is properly maintained and operated.
Issue Date: 2021/07/01
BSMI Notice
安全諮詢及注意事項
請使用原裝電源供應器或只能按照本產品注明的電源類型使用
本產品。
清潔本產品之前請先拔掉電源線。請勿使用液體、噴霧清潔劑或
濕布進行清潔。
注意防潮請勿將水或其他液體潑灑到本產品上。
插槽與開口供通風使用以確保本產品的操作可靠並防止過熱
請勿堵塞或覆蓋開口。
請勿將本產品置放於靠近熱源的地方。除非有正常的通風否則
不可放在密閉位置中。
請不要私自拆開機殼或自行維修如產品有故障請與原廠或代理
商聯繫。
此為甲類資訊技術設備于居住環境中使用時可能會造成射頻擾動
在此種情況下使用者會被要求採取某些適當的對策。
限用物質含有情況標示聲明書
產品元件名稱
PCB
外殼
產品元件名稱
PCB
外殼
限用物質及其化學符號
備考: "○"系指該項限用物質之百分比含量未超出百分比含量基準值。
Pb
Cd
Hg
六價鉻
Cr+6
多溴聯苯
PBB
溴二苯醚
PBDE
Explanation of the symbols on the product label
DC voltage
RECYCLING
This product bears the selective sorting symbol
for Waste electrical and electronic equipment
(WEEE). This means that this product must be
handled pursuant to European directive
2012/19/EU in order to be recycled or
dismantled to minimize its impact on the
environment.
User has the choice to give his product to a
competent recycling organization or to the
retailer when he buys a new electrical or
electronic equipment.
AC voltage
Indoor use only
Operator’s manual
Caution

Especificaciones del producto

Marca: TP Link
Categoría: No categorizado
Modelo: PSM150-AC

¿Necesitas ayuda?

Si necesitas ayuda con TP Link PSM150-AC haz una pregunta a continuación y otros usuarios te responderán




No categorizado TP Link Manuales

No categorizado Manuales

Últimos No categorizado Manuales