Tripp Lite BP36V42-3U Manual de Usario

Lee a continuación 📖 el manual en español para Tripp Lite BP36V42-3U (52 páginas) en la categoría No categorizado. Esta guía fue útil para 6 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/52
Owner’s Manual
BP Series
External Battery Packs
Not suitable for mobile applications.
Introduction 2
Important Safety Instructions 2
Mounting 4
Connection 11
Maintenance 12
Warranty and Product Registration 13
Español 14
Français 27
 40
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2019 Tripp Lite. All rights reserved.
PROTECT YOUR INVESTMENT!
Register your product for quicker service and ultimate peace of mind.
You could also win an ISOBAR6ULTRA surge protector—a $100 value!
www.tripplite.com/warranty
24V Battery Packs 36V Battery Packs 48V Battery Packs 72V Battery Packs
BP24V15RT2U, 14AH
BP24V28-2U, 28AH
BP24V36-2US, 36AH
BP24V70-3U, 70AH
BP36V15-2U, 18AH
BP36V42-3U, 21AH
BP48V24-2U, 18AH
BP48V27-2US, 27AH
BP48V48RT4U, 42AH
BP48V60RT-3U, 42AH
BP72V15-2U, 15AH
BP72V18-2US, 18AH
BP72V28RT-3U, 28AH
19-01-135-9336FF.indb 1 1/9/2019 1:17:56 PM
2
Introduction
Important Safety Instructions
Tripp Lite BP Series External Battery Packs are designed for use with various Tripp Lite
UPS systems equipped with external battery pack connectors.
SAVE THESE INSTRUCTIONS
WARNING! The mounting shelves are not intended to support more than
one battery pack. Do not stack multiple battery packs on a single set of
mounting shelves. Failure to follow this warning may lead to product
damage and/or risk of personal bodily harm.
Use caution when lifting battery packs. Because of the considerable weight of
all battery packs, at least two people should assist in lifting and installing
them.
Make certain the battery packs and UPS use the same DC voltage before
connecting them.
Use only Tripp Lite external battery packs with overcurrent protection.
Installation is by qualified service personnel only. Contact Tripp Lite Customer
Support at 773.869.1234 for the appropriate Tripp Lite battery pack to
connect.
Your external metal battery cabinets are provided with a means for
equipotential protective bonding for safety. When using 2-pin connector
external batteries, be sure to bond the metal enclosure of your external
battery to the metal enclosure of the UPS system. Three-pin/conductor battery
packs are equipped with a ground bond plug. Plastic enclosures do not require
bonding. See below for ground bonding strap requirements:
24V Battery Packs
BP24V15RT2U: Plastic enclosure, so ground bonding strap is not required.
BP24V28-2U: 12 AWG ground bonding strap
BP24V36-2US: 12 AWG ground bonding strap
BP24V70-3U: 12 AWG ground bonding strap
36V Battery Packs
BP36V15-2U: 12 AWG ground bonding strap
BP36V42-3U: 12 AWG ground bonding strap
48V Battery Packs
BP48V24-2U: 12 AWG ground bonding strap
BP48V27-2US: 12 AWG ground bonding strap
BP48V48RT4U: 12 AWG ground bonding strap
BP48V60RT-3U: 12 AWG ground bonding strap
Note: The battery connector on 72V battery packs has a built-in ground bonding plug, so an
additional ground bonding strap isn’t needed.
19-01-135-9336FF.indb 2 1/9/2019 1:17:57 PM
3
Important Safety Instructions
Securely attach the provided ground strap to the UPS system as illustrated
below:
Use of this equipment in life support applications where failure of this
equipment can reasonably be expected to cause the failure of the life support
equipment or to significantly affect its safety or effectiveness is not
recommended. Do not use this equipment in the presence of a flammable
anesthetic mixture with air, oxygen or nitrous oxide.
Suggested mounting procedures are for common rack types and may not be
appropriate for all rack configurations. User must determine the fitness of rack and
wall-mount hardware and procedures before mounting.
When connecting multiple battery packs to a single UPS, the battery packs should be
approximately the same age.
It is normal for sparks to occur when connecting external batteries.
Do not unplug external batteries from the UPS while the UPS is operating on battery
power, due to the possibility of dangerous arcing.
Batteries can present a risk of electrical shock and burn from high short-circuit
current. Observe proper precautions. Do not dispose of the batteries in a fire. Do not
open the UPS or batteries. Do not short or bridge the battery terminals with any
object. Unplug and turn off the UPS before performing battery replacement. Use tools
with insulated handles. There are no user-serviceable parts inside the UPS. Battery
replacement should be performed only by authorized service personnel using the
same number and type of batteries (Sealed Lead-Acid). The batteries are
recyclable. Refer to your local codes for disposal requirements or visit
http://www.tripplite.com/support/recycling-program for recycling information. Tripp Lite
offers a complete line of UPS System Replacement Battery Cartridges (R.B.C.).
Visit Tripp Lite on the Web at http://www.tripplite.com/products/battery-finder/ to locate
the specific replacement battery for your UPS.
19-01-135-9336FF.indb 3 1/9/2019 1:17:57 PM

Especificaciones del producto

Marca: Tripp Lite
Categoría: No categorizado
Modelo: BP36V42-3U

¿Necesitas ayuda?

Si necesitas ayuda con Tripp Lite BP36V42-3U haz una pregunta a continuación y otros usuarios te responderán




No categorizado Tripp Lite Manuales

No categorizado Manuales

Últimos No categorizado Manuales