Owner’s Manual
1
SmartPro® LCD UPS Systems
Models:
SMART1200LCD
(Series Number: AGOM5515)
Important Safety Instructions 2
Quick Installation 4
Basic Operation 5
UPS On/Off 5
LCD 5
LCD Features 5
Display Power Conditions 5
Enable/Disable Alarm 5
LCD Brightness 6
Self-test 6
Power Sensitivity 6
Scroll Control 7
External Battery Settings 7
Error Messages 7
Features 8
Battery Replacement 9
Storage and Service 11
Product Registration 11
Español 13
Français 25
SMART1500LCD
(Series Number: AG-8869)
SMART1500LCDXL
(Series Number: AGSM8191)
Not suitable for mobile applications
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2017 Tripp Lite. All rights reserved.
PROTECT YOUR INVESTMENT!
Register your product for quicker service
and ultimate peace of mind.
You could also win an
ISOBAR6ULTRA surge protector—
a $100 value!
www.tripplite.com/warranty
17-02-143-9336B5.indb 1 3/14/2017 2:03:49 PM
Important Safety Instructions
2
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the
installation, operation and storage of this product. Failure to heed these warnings
may affect your warranty.
UPS Location Warnings
• Install your UPS indoors, away from excess moisture or heat, conductive contaminants,
dust or direct sunlight.
• For best performance, keep the indoor temperature between 32º F and 104º F
(0º C and 40º C).
• Leave adequate space around all sides of the UPS for proper ventilation.
• Do not mount unit with its front or rear panel facing down (at any angle). Mounting
in this manner will seriously inhibit the unit’s internal cooling, eventually causing
product damage not covered under warranty.
UPS Connection Warnings
• Connect your UPS directly to a properly grounded AC power outlet. Do not plug the UPS
into itself; this will damage the UPS.
• Do not modify the UPS’s plug, and do not use an adapter that would eliminate the UPS’s
ground connection.
• Do not use extension cords to connect the UPS to an AC outlet.
• If the UPS receives power from a motor-powered AC generator, the generator must provide
clean, filtered, computer-grade output.
• The mains socket outlet that supplies the UPS should be easily accessible and located
near the UPS.
• The building installation provides short circuit back-up protection.
EMI Filter
Surge Protecon
Inverter
Charger
C trolon
Transformer
Line Cutoff Relay
Boost 1 R y ela
Cut Relay
AC In
AC Out
USB Com Port
Serial Com Port
+Internal
Baery
External Baery
Connector *
LCD Display, Switches
Circuit Breaker
Teleprotect Circuit
*If applicable
17-02-143-9336B5.indb 2 3/14/2017 2:03:49 PM
Important Safety Instructions
3
Equipment Connection Warnings
• Use of this equipment in life support applications where failure of this equipment can
reasonably be expected to cause the failure of the life support equipment or to significantly
affect its safety or effectiveness is not recommended.
• Do not connect surge protectors or extension cords to the output of your UPS. This might
damage the UPS and may affect the surge protectors and UPS warranties.
• Connect the UPS to an outlet that is adequately protected against excess currents, short
circuits and earth faults as part of the building installation.
Battery Warnings
• Your UPS does not require routine maintenance. Do not open your UPS for any reason.
There are no user-serviceable parts inside.
• Batteries can present a risk of electrical shock, chemical hazard and burn from high short-
circuit current. Observe proper precautions. Do not dispose of the batteries in a fire. Do
not open the
UPS or batteries. Do not short or bridge the battery terminals with any object. Unplug and
turn off the UPS before performing battery replacement. Use tools with insulated handles.
There are no user-serviceable parts inside the UPS. Battery replacement should be
performed only by authorized service personnel using the same number and type of
batteries (Sealed Lead-Acid). The batteries are recyclable. Refer to your local codes for
disposal requirements or visit http://www.tripplite.com/support/recycling-program for
recycling information. Tripp Lite offers a complete line of UPS System Replacement
Battery Cartridges (R.B.C.).Visit Tripp Lite on the Web at
http://www.tripplite.com/products/battery-finder/ to locate the specific
replacement battery for your UPS.
• When adding an external battery pack, connect only a Tripp Lite recommended battery pack
of the correct voltage and type. Do not connect or disconnect the external battery pack
when the UPS is operating on battery power. Visit Tripp Lite on the Web at
www.tripplite.com/support to locate the specific battery for your UPS.
UPS and Battery Recycling
Please recycle Tripp Lite Products. The batteries used in Tripp Lite products are
sealed Lead-Acid batteries. These batteries are highly recyclable. Please refer to
your local codes for disposal requirements.
You can call Tripp Lite for recycling info at 1.773.869.1234.
You can go to the Tripp Lite Website for up-to-date information on recycling the
batteries or any Tripp Lite product. Please follow this link:
http://www.tripplite.com/support/recycling-program/
17-02-143-9336B5.indb 3 3/14/2017 2:03:49 PM
Especificaciones del producto
Marca: | Tripp Lite |
Categoría: | Unión Postal Universal |
Modelo: | SmartPro SMART1200LCD |
¿Necesitas ayuda?
Si necesitas ayuda con Tripp Lite SmartPro SMART1200LCD haz una pregunta a continuación y otros usuarios te responderán
Unión Postal Universal Tripp Lite Manuales
20 Octubre 2024
18 Octubre 2024
9 Octubre 2024
9 Octubre 2024
4 Octubre 2024
2 Octubre 2024
29 Septiembre 2024
29 Septiembre 2024
21 Septiembre 2024
19 Septiembre 2024
Unión Postal Universal Manuales
- Unión Postal Universal AEG
- Unión Postal Universal IKEA
- Unión Postal Universal HP
- Unión Postal Universal Apc
- Unión Postal Universal Lenovo
- Unión Postal Universal Energenie
- Unión Postal Universal Voltcraft
- Unión Postal Universal Emerson
- Unión Postal Universal Steren
- Unión Postal Universal Adj
- Unión Postal Universal Digitus
- Unión Postal Universal LevelOne
- Unión Postal Universal Eaton
- Unión Postal Universal CyberPower
- Unión Postal Universal Block
- Unión Postal Universal Liebert
- Unión Postal Universal Avocent
- Unión Postal Universal Furman
- Unión Postal Universal Minuteman
- Unión Postal Universal Maruson
- Unión Postal Universal V7
- Unión Postal Universal Phoenix Contact
- Unión Postal Universal Puls Dimension
- Unión Postal Universal Vanson
- Unión Postal Universal Salicru
- Unión Postal Universal Equip
- Unión Postal Universal Approx
- Unión Postal Universal SurgeX
- Unión Postal Universal Murr Elektronik
- Unión Postal Universal Altronix
- Unión Postal Universal Ditek
- Unión Postal Universal Bxterra
- Unión Postal Universal Middle Atlantic
- Unión Postal Universal FSP
- Unión Postal Universal Atlantis Land
- Unión Postal Universal PowerWalker
- Unión Postal Universal FSP/Fortron
- Unión Postal Universal Online USV
Últimos Unión Postal Universal Manuales
24 Octubre 2024
22 Octubre 2024
22 Octubre 2024
22 Octubre 2024
18 Octubre 2024
12 Octubre 2024
12 Octubre 2024
12 Octubre 2024
12 Octubre 2024
12 Octubre 2024