Vimar 01489 Manual de Usario
Vimar
Regulador de intensidad
01489
Lee a continuación 📖 el manual en español para Vimar 01489 (2 páginas) en la categoría Regulador de intensidad. Esta guía fue útil para 3 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/2

Viale Vicenza 14
36063 Marostica VI - Italy
www.vimar.com
01489EN 01 1904
01489
Home automation control device with four push buttons, 1 0/1-10 V
SELV output, 1 NO contact relay output 2A 120-240 V~ 50/60 Hz for
ballast and LED driver, visible in darkness with RGB LEDs with inten-
sity adjustment, to be completed with interchangeable half-button
caps comprising 1 or 2 modules (Eikon) or 2 modules (Arkè or Plana).
The device is equipped with independent push buttons that can also be configured
as rocker buttons, 0/1-10 V SELV proportional actuator for ballast and LED driver (the
relay cuts off the load), 0/1-10 V SELV climate control proportional relay for motorised
proportional valves (the relay does not cut off the load), RGB LEDs with configurable
colour, for setting and control functions in By-me home automation systems. The
0/1-10 V output is galvanically isolated (double insulation or reinforced insulation)
from the mains power supply and from the BUS. For the Eikon and Arkè series, all
the button covers, whether from the catalogue or customised, have symbols which
can be backlit with customisable RGB colours.
FEATURES.
• Rated supply voltage: 29 V BUS
• Absorption from the BUS: 25 mA
• Distance between 0/1-10 V output and load: max 50 m with twisted cable
• Terminals:
- TP bus,
- relay contacts (C, NO)
- 0/1-10 V SELV control
- 0/1-10 V SELV maximum output current:
- 30 mA absorption (load with 0/1-10 V SELV interface active)
- 10 mA delivery (load with 0/1-10 V SELV interface passive)
• 0/1-10 V SELV overload-protected output
• 4 push buttons which can also be configured as rocker buttons
• 4 RGB LEDs with configurable colour
• red LED and configuration push button
• Operating temperature: -5 °C ÷ +45 °C (indoor use)
• Protection degree: IP20
• Device 01489 should be configured with the Automation Gateway 01410-01411
and App VIEW Pro.
• Not compatible with By-me control panels 21509 and EasyTool Professional.
CONTROLLABLE LOADS.
• Relay output (120 - 240 V~ controllable loads, NO contact):
- ballast and 2 A LED driver (5,000 cycles)
• 0/1-10 V SELV output:
- ballast and LED driver with 0/1-10 V SELV input
- motorised proportional valves with 0/1-10 V SELV input
Plug&Play.
CAUTION: The plug&play mode requires the system to include only plug&play
devices and not devices configured in the By-me Plus system.
For operation in Plug&Play mode, only install the 1-module fixed half-button caps
on the device.
In the absence of a configuration, the device is pre-configured as a 0/1-10V propor-
tional actuator:
- briefly press to B activate the relay actuator of the device;
- press for a prolonged time to make the (increase);B upwards adjustment
- briefly press to C deactivate the relay actuator of the device;
- press for a prolonged time to make the (decrease);C downwards adjustment
- press to send a “ ” scenario over the bus;F Lights OFF
- press to send a “E Lights OFF and roller shutters DOWN” scenario over the bus.
When push buttons are pressed, the LEDs are on for 3 s.
SETTING THE COLOUR OF THE LEDS.
PLUG&PLAY mode.
• Procedure activation: simultaneously press push buttons E and F for a prolonged
time; the LEDs will all illuminate in the colour currently set.
• E F Colour selection: briefly press push button or to view the next colour.
• Saving the colour and exiting the procedure: press push button F or E for a
prolonged time.
WEEE - User information
The crossed bin symbol on the appliance or on its packaging indicates that the product at the end of
its life must be collected separately from other waste. The user must therefore hand the equipment
at the end of its life cycle over to the appropriate municipal centres for the differentiated collection of
electrical and electronic waste. As an alternative to independent management, you can deliver the
equipment you want to dispose of free of charge to the distributor when purchasing a new appliance
of an equivalent type. You can also deliver electronic products to be disposed of that are smaller
than 25 cm for free, with no obligation to purchase, to electronics distributors with a sales area of at
least 400 m2. Proper sorted waste collection for subsequent recycling, processing and environmen-
tally conscious disposal of the old equipment helps to prevent any possible negative impact on the
environment and human health while promoting the practice of reusing and/or recycling materials
used in manufacture.
• Exiting the procedure without saving the colour: automatic after a timeout of 5 s.
B y-me Plus SYSTEM.
• The colour is set from the App using the respective menus.
OPERATION.
Home automation device acting as a proportional actuator.
• Possible functions:
- Dimming control/adjustment of ballast and LED driver with 0/1-10 V SELV control
interface (the load can be cut off by the relay).
- Operating motorised proportional valves with 0/1-10 V SELV control interface for
temperature control systems (the load cannot be cut off by the relay).
At power-on the relay is set to OFF status. The subsequent status varies according
to a configurable parameter.
CONFIGURATION.
For the configuration operations, see the By-me Plus system manual.
• Functional units: 7
- Top left push button functional unit
- Bottom left push button functional unit
- Top right push button functional unit
- Bottom right push button functional unit
- Left rocker button functional unit
- Right rocker button functional unit
- Proportional actuator functional unit
INSTALLATION RULES.
• If motorised valves are connected, these must be class III and equipped with the
symbol.
• If ballasts or LED drivers are connected, these can either be class I or class II with
the 0/1-10V SELV output.
• The 0/1-10 V interface of the controlled loads must be isolated from the mains
power supply by double insulation or by reinforced insulation.
• Installation must be carried out by qualified persons in compliance with the current
regulations regarding the installation of electrical equipment in the country where
the products are installed.
• The relay output power circuit must be protected against overloads by installing a
device, fuse or automatic 1-way switch, with a rated current not exceeding 10 A.
• Installation in flush mounting box. In the event of installation on a control unit, use
the related accessory art. V51922.
• If this device is used for purposes other than those specified by the manufacturer,
the protection provided may be compromised.
• Observe the maximum current and voltage values given for the device.
REGULATORY COMPLIANCE.
LV Directive. EMC directive. Standards EN 60669-2-5, EN 50491.
REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces
of lead.

Viale Vicenza 14
36063 Marostica VI - Italy
www.vimar.com
01489EN 01 1904
CONNECTIONS
Maximum distance between actuator and valve: 50 m. Use a twisted cable with a minimum cross-section of 0.5 mm
2
(art. 01840).
1. Connection with motorised proportional valve 2. Connection to ballast or LED driver
FRONT AND REAR VIEW
Key:
A: Configuration push button
B. Push button 1
C. Push button 2
D. LED
E: Push button 3
F: Push button 4
B
C
F
E
A
DTP bus
0/1-10 V control
BUS
C
0/1-10V
2A 120-240V~
50/60Hz µ
NO
–+
–+
relay contacts
NL
BALLAST
N
L
BUS
C
0/1-10V
2A 120-240V~
50/60Hz µ
NO
–+
–+
–
0/1-10V
SELV
–+
+
BUS
C
0/1-10V
2A 120-240V~
50/60Hz µ
NO
–+
–+
–
K
0/1-10V
SELV
24Vac
SELV 16887
N
L
–+
+
Especificaciones del producto
Marca: | Vimar |
Categoría: | Regulador de intensidad |
Modelo: | 01489 |
¿Necesitas ayuda?
Si necesitas ayuda con Vimar 01489 haz una pregunta a continuación y otros usuarios te responderán
Regulador de intensidad Vimar Manuales

1 Septiembre 2024

31 Agosto 2024

30 Agosto 2024

30 Agosto 2024

29 Agosto 2024

29 Agosto 2024

28 Agosto 2024

28 Agosto 2024

28 Agosto 2024

28 Agosto 2024
Regulador de intensidad Manuales
- Regulador de intensidad Arendo
- Regulador de intensidad GE
- Regulador de intensidad Sonoro
- Regulador de intensidad Eminent
- Regulador de intensidad TP Link
- Regulador de intensidad Elro
- Regulador de intensidad ABB
- Regulador de intensidad Velleman
- Regulador de intensidad American DJ
- Regulador de intensidad Steinel
- Regulador de intensidad Cotech
- Regulador de intensidad DIO
- Regulador de intensidad Merten
- Regulador de intensidad Hager
- Regulador de intensidad Chauvet
- Regulador de intensidad Grasslin
- Regulador de intensidad Jung
- Regulador de intensidad Tronic
- Regulador de intensidad Fibaro
- Regulador de intensidad Eurolite
- Regulador de intensidad Homematic IP
- Regulador de intensidad Adastra
- Regulador de intensidad Berker
- Regulador de intensidad Mercury
- Regulador de intensidad Handson
- Regulador de intensidad Velbus
- Regulador de intensidad InterBar
- Regulador de intensidad GAO
- Regulador de intensidad Intertechno
- Regulador de intensidad Schneider Electric
- Regulador de intensidad Tradim
- Regulador de intensidad EtiamPro
- Regulador de intensidad Ltech
- Regulador de intensidad Ehmann
- Regulador de intensidad Peha
- Regulador de intensidad VAMA
- Regulador de intensidad Paladin
- Regulador de intensidad AMX
- Regulador de intensidad Bearware
Últimos Regulador de intensidad Manuales

30 Septiembre 2024

21 Septiembre 2024

17 Septiembre 2024

17 Septiembre 2024

17 Septiembre 2024

17 Septiembre 2024

17 Septiembre 2024

17 Septiembre 2024

17 Septiembre 2024

17 Septiembre 2024