Yorkville Synergy SA115S Manual de Usario

Yorkville Vocero Synergy SA115S

Lee a continuación 📖 el manual en español para Yorkville Synergy SA115S (10 páginas) en la categoría Vocero. Esta guía fue útil para 14 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/10
OWNER’S MANUAL
MANUEL DE L’UTILISATEUR
SA115S
2
1. Power Switch and Indicator
The green power LED illuminates when the power switch is turned to the On position and AC voltage is sup-
plied. When the power is removed or the power switched is moved to the off position the green power indicator
will blink while the power supply is discharging. The processing circuitry will not reboot unless the power supply
is fully discharged before being turned back on. It is not necessary to reboot however. Turning the power back
on before the power supply is discharged will simply resume normal operation.
2. PowerCON TRUE AC Loop Thru
As a standard, the AC inlet on the SA115S accepts locking PowerCON TRUE power cords. There is also an AC
outlet that can be used to loop power through to other cabinets in your array using a male to female PowerCON
TRUE looping power cord. Check with your local Yorkville dealer for availability of these accessory cords.
IMPORTANT: DO NOT EXCEED THE CURRENT RATING OF THE POWER and ACCESSORY CORDS.
PLEASE READ THE SECTION OF THIS MANUAL CALLED CASCADE INSTALLATION
3. Input Jack
This female-XLR accepts line level XLR microphone cables. For best noise reduction use balanced sources.
4. Dual Link Outputs
These XLR male connectors can be used with a standard XLR cable to daisy-chain up to 20 SA115S or SA315
cabinets without signal degradation. Simply loop from one cabinet’s Link jack to the next cabinets Input jack. In
many cases this limit of 20 cabinets can be exceeded, consult Yorkville Sound for more details.
5. SA115S Level Control
This control adjusts the volume level of the SA115S relative to the input signal level. Mixers and other audio
sources connected to the SA115S tend to have different output voltages, which mean the level control on the
SA115S is used to ne tune the cabinet’s volume relative to the mixer settings. It is perfectly acceptable to set
the SA115S Level above or below the center 0 dB setting.
6. Clip, X-Max, VC-Therm, Activity Indicators
The Clip and Limit LED indicators illuminate to guide the user to proper operating levels.
Illumination either of the yellow Limit LEDs indicates that a level has been reached where the SA115S limit-
ers are reducing the signal internally to prevent damage or distortion. It also indicates that further increases in
input level or increasing the SA115S Level control position will not appreciably increase acoustic output.
The red Clip LED indicates that the input level is excessive and further increases in level will cause severe
distortion The input signal should be reduced at the source until Clip activity ceases. The clip indicator comes
on at 12 Vrms,16 volts peak. The input clips at 17 Vrms, 24 volts peak.
The activity Indicator comes on at 5 mVrms or -45 dBV.
7. Line Current Limit Control
The Line Current Limit control allows the power to be reduced to allow operation on limited power availabil-
ity. Full power transients will be allowed through but if the average power is excessive then the power will be
limited. This control works by advancing the limiter that limits the voice coil temperature and by monitoring
the current draw. In the 5 amp position the average power is limited only by the voice coil temperature. In the
4 amp position with most music, the limiter will be only active occasionally depending on the music content.
In the 3 amp position certain types of music will not be limited, primarily music without deep bass or where
the bass is unprocessed. The 2 amp position will signicantly reduce the output when the music content has
continuous bass content below 45 Hz. The green power on indicator will dim to indicate when the line cur-
rent limiter is active. A small amount of dimming indicates that the advanced thermal limiter is active while
signicant dimming indicates that the line current monitoring system has detected excessive line current.
Low line voltage typically due to long power supply cables may cause excessive line current, the line current
monitoring system will prevent this from tripping the power source circuit breakers.
3
Enceinte Ampliée Synergy SA115S
Nous vous remercions d’avoir choisi le caisson de basse Synergy SA115S de Yorkville, le caisson de basse com-
pagnon du SA153. La série SA excelle dans les applications de renforcement du son où un système Line array est
souhaité mais ne peut être facilement installé.
Caractéristiques de l’Enceinte
Le SA115S est construit en contreplaqué de bouleau multi-plis haute résistance pour une durabilité ultime. Le
SA115S utilise un seul woofer de 15 pouces à longue portée.
Caractéristiques Électroniques
Une plateforme DSP proprtaire de Yorkville assure le traitement pour éviter la sur-excursion (X-Max), la surchauffe de la
bobine mobile (VC thermique) et l’écrêtage. Le DSP utilise desltres IIR pour le crossover et l’égalisation et un petit délai
est ajou pour saligner avec l’enceinte SA153. Le limiteur X-Max et le limiteur thermique VC sont tous deux sensibles à
la fréquence et calibrés pour correspondre aux caractéristiques du système de haut-parleurs et de caissons. Le limiteur
thermique VC peut être avan pour limiter la consommation d’énergie dans les cas où il n’y a pas assez de puissance
disponible. Le limiteur X-Max est plus rapide, presque instanta. Le limiteur VC-thermal agit plus lentement et fonc-
tionne généralement vers lan d’un battement de basse à 120 bpm.
Lamplicateur est une conception de classe D à haute extension dynamique. Il est équi d’une grande banque de
condensateurs an que les transitoires des basses dépendent moins de la qualité de la ligne électrique.
Les indicateurs du limiteur indiquent quand les limiteurs thermiques X-max ou VC sont actifs. En général, le
limiteur X-max est plus actif mais cela dépend du contenu. L’effet de l’avance de la puissance de ligne peut être
observé en surveillant attentivement ces voyants de limiteur lorsque la commande est modiée pendant le fonc-
tionnement en limite. Le voyant VC-therm s’allume plus tôt lorsque le limiteur de Puissance Moyenne est avancé.
Avec de nombreux types de musique, l’effet du limiteur VC-therm sera négligeable.
SUB
LEVEL
LINE
CURRENT
LIMIT
dB
3
3
3
3
33
AMPS
4
4
4
4
44
5
5
5
5
55
2
2
2
2
22
Off
Off
Off
Off
OffOff
8
-
12
-
24
4
6
-
6
2
-
2
1
0
0
0
0
00
Activity
Pwr
Limit
X-MAX
VC
Therm
Input Clip
AL CONNECTED IN PARALLELL
5A = MAX Output
4A = 90% Output
3A = 80% Output
2A = 60% Output

Especificaciones del producto

Marca: Yorkville
Categoría: Vocero
Modelo: Synergy SA115S

¿Necesitas ayuda?

Si necesitas ayuda con Yorkville Synergy SA115S haz una pregunta a continuación y otros usuarios te responderán




Vocero Yorkville Manuales

Vocero Manuales

Últimos Vocero Manuales