ZKTeco AQD-V43[WIFI] Manual de Usario

ZKTeco No categorizado AQD-V43[WIFI]

Lee a continuación 📖 el manual en español para ZKTeco AQD-V43[WIFI] (1 páginas) en la categoría No categorizado. Esta guía fue útil para 8 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/1
2 3 4 5 6 7 8 10 11
Display method: 4.3“ LCD screen display, 480*270 pixels
Atmospheric pressure: 86Kpa to 106Kpa
Detection method for CO2: Infrared (NDIR)
Detection method for PM: Laser Scattering
Sampling time: 1.5 seconds
Product Size: 145*78*97.2mm
Detection temperature: -10°C to 50°C
Relative humidity: 20% to 85%
Storage temperature: -10°C to 60°C
Concentration unit for CO2: PPM
Concentration unit for PM: ug/m 3
Concentration unit for HCHO and TVOC: mg/m 3
Power source: Lithium battery with 3000mAh capacity;
5V DC power charging via micro USB port
Product weight: 235g
Please read the instructions carefully before using this
device.
Please let the device work short mins outdoors before
use for most accurate results.
Please keep the manual handy for quick reference and
troubleshooting.
Avoid covering the air intake areas during use to avoid
inaccurate measurements.
Avoid use of solvents to clean the product as residual
fumes will skew air quality readings.
Avoid water or other liquids near the product to avoid
electrical damage.
Do not allow unauthorized modication or repair of this
product.
- 4.3” color liquid crystal display (LCD), 480*270 pixels
- Test variables: Carbon dioxide (CO2), PM2.5/1.0/10,
formaldehyde, TVOC, temperature, humidity
- Large 3000mAh capacity Lithium battery
- On-board fan to draw in ambient air for more accurate
real-time results
- 5V Micro USB charging
- Low battery warning
This product is a multifunctional air quality monitor that
detects Carbon dioxide (CO2), Formaldehyde (HCHO),
Total Volatile Organic Compounds (TVOC), Particulate
Matter <2.5 micron-sized particles (PM2.5/1.0/10),
Temperature, and Humidity with clock and record
function. As a scientic air quality detection device, it
combines multiple air sensors with a built-in fan to allow
real-time monitoring of Carbon dioxide (CO2), formalde-
hyde (HCHO), total volatile organic compounds (TVOC),
PM2.5/1.0/10, temperature, and humidity on its digital
LCD display.
Product Specications
Product Description
Considerations Instructions
Precautions
Features
Air Quality monitor x 1
Micro USB charging cable x 1
Product Manual x 1
Product List
1. Start Up
2. Switching Among Data Display Formats(Figure 1-5) 6. Alarm Threshold
If the alarm sounds noisy, you can turn it o.
please read page 7 about how to set the "Buzzer".
When you long-press the center power buttion, the air
quality monitor will boot up. Detector will proceed through
its warm-up sequence for about 3 minutes to allow
sensors to preheat and fan to draw in fresh ambient air.
This is necessary for accurate results.
DATE: Change the date by using the up and down button.Conrm
each setting with one press on the on/o button.
TIME: Change the time by using the up and down button and by
Conrming with the on/o button.
UNIT: Change the temperature unit between Celcius(°C) or
Fahrenheit(°F).
Buzzer: use up/down buttons to select whether to turn the
alarm buzzer on/of.
Press the up or down buttons to switch among data display
formats(gures 1-5) that displays air quality readings in various
formats:
Default factory value alarm threshold levels for HCHO:
0.1mg/m3. when reach 0.1mg/m 3, Device alarm sounds.
HCHO (formaldehyde) ideal range: <=0.10mg/m3.
7. AQI (Ari quality index)
Green Color (Good): 0 to 50
Yellow Color (Slight): 51 to 100
Red Color (Moderate): 101 to 200
Purple Color (Serious): 201 to 500
TVOC Specications:
Measuring principle: Semiconductor
Measuring range: 0.000 to 9.999mg/m 3
Resolution: 0.001mg/m3
Temperature and Humidity Technical Indicators
Measuring range: -10 to 50°C
Measurement accuracy: ±1°C
Humidity range: 20% to 85% RH
Measurement accuracy: ±4% RH
8. Parameters
CO2 Technical Indicators
Measuring range: 400 to 5000PM
Sensor for CO2: Infrared (NDIR)
Resolution: 1PPM
PM2.5, PM10, PM1.0 Specications:
Measuring principle: Laser Scattering
Measuring range: 0 to 999ug/m 3
Resolution: 1ug/m3
Formaldehyde Specications:
Measuring principle: Electrochemistry
Measurement range: 0.000 to 1.999mg/m 3
Resolution: 0.001mg/m3
3. Set up (Figure 6)
Double press Power button to enter the Set up screen.
4. About Charging
When low battery icon is displayed, the device needs to
be charged. Insert the included or another compatible
micro USB charging cable into the device. Attach the
other end to a USB DC charger (such as a smart phone
charger) that outputs DC 5V at >=1000mA. Fully charge
for at least 2-3 hours before use. Avoid charging with a
USB computer port which only outputs 500mA.
5. History (Figure 3, Figure 5)
Graph shows the last 5 data values for PM2.5, Formalde-hyde
and taken every 10 minutes over the previous 50 minutes.
Figure 1
Figure 3 Figure 4
Figure 6 Figure 3 Figure 5
Figure 5
Figure 2
1) Power/OK/Menu Button, used to conrm highlighted
options or to turn device on/o by pressing for 3 seconds.
2) /Switch/Decrease Button, used to scroll between
interfaces.
3) /Switch/Increase Button, used to scroll between interfaces.
4) Micro USB charging Port.
1
2
4
3
9Copyright © 2021 ZKTECO CO., LTD. All Rights Reserved.
Version: 1.0
User Manual
Air Quality Detector AQD-V43[WIFI]
Formaldehyde Standard
CO2 Air Quality Grade Range
TVOC Standard
Air Quality
level
Excellent ≤800
Good 800 to 1000
Poor +1000
CO2 average standard
value (PPM)
Formaldehyde
Less than 0.100: Safety range
0.101 to 0.200: Slight pollution
0.201 to 0.300: Moderate pollution
0.301 or more: Heavey pollutiona
Less than 0.600: Safety range
Achieve 0.601 or more: Exceeding the
standard can cause respiratory system
Abnormal, inamed, cancerous, etc.
Air Quality
Level
Excellent
Good
Light pollution
Mouderate pollution
Heavy pollution
Serious pollution
PM2.5 (ug/m3)
Average Standerd Value
0 to 35
36 to 75
76 to 115
116 to 150
151 to 250
more than 250
PM2.5 Air Quality Rating Range
1. Download and install the Smart App through the Google Play Store NGTeco
or Apple App Store. Or to scan QR code (Picture 1) to download the NGTeco
APP, then registration and login it.
2. Turn on the air quality monitor (AQD-V43[WIFI]) by long pressing Power button.
3. Connect your phone to a WiFi network and open the Smart App.NGTeco
(Long-press button for 3 seconds to enter regular wi connection
model, Wi icon would quick ash.)
4. Select Add Device, then Click the scan icon in the upper right corner of
NGTeco interface (Picture 2), and scan the QR code (Picture 3) to connect
and follow the instructions of interface.NGTeco
How to connect your device to an Android or Apple
iOS smartphone via NGTeco Smart App
Picture 2
Picture 1
Picture 3
Ctra. Fuencarral 44. Edicio 1, Planta 2.
28108 Alcobendas, Madrid. Spain
Phone: +34 916 532 891
Mail: sales@zkteco.eu
www.zkteco.eu

Especificaciones del producto

Marca: ZKTeco
Categoría: No categorizado
Modelo: AQD-V43[WIFI]

¿Necesitas ayuda?

Si necesitas ayuda con ZKTeco AQD-V43[WIFI] haz una pregunta a continuación y otros usuarios te responderán




No categorizado ZKTeco Manuales

No categorizado Manuales

Últimos No categorizado Manuales