Zodiac Ei2 Manual de Usario

Lee a continuación 📖 el manual en español para Zodiac Ei2 (12 páginas) en la categoría No categorizado. Esta guía fue útil para 9 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/12
Saltwater Chlorinator
Owners Manual
2
Read this manual carefully before installing, maintaining or repairing this appliance!
The symbol indicates important informa" on that it is impera" ve to take into considera" on in
order to avoid all risks of harm to persons or damage to the appliance.
The symbol indicates useful informa" on.
Warnings
At Zodiac, we take safety seriously. Always exercise cau on when using electrical appliances and follow
the instruc ons. Failure to do so could result in permanent injury, electrocu on or drowning.
Important Informa" on
YOU MUST READ THIS INFORMATION BEFORE INSTALLATION. ALWAYS READ THE LABEL AND OPERATION
MANUAL BEFORE USING. PLEASE KEEP YOUR MANUAL AS IT CONTAINS YOUR WARRANTY.
General Warnings
Zodiac saltwater chlorinators are designed for domes c swimming pool use only. Contrary use could
aff ect performance and void warranty. Opera ng a chlorinator without water owing through the cell
may cause a build up of fl ammable gases, resul ng in fi re or explosion. Keep equipment out of reach of
children. A damaged supply cord should only be replaced by the manufacturer, or an authorized Zodiac
service agent.
When installing and using this electrical equipment, always follow basic safety precau ons. Before
performing installa on, disconnect all power. For swimming pools, Zodiac recommends a range between
1 - 3 parts Per Million (ppm) of free available chlorine must be maintained at all  mes. Service to Zodiac
equipment should only be carried out by qualifi ed and authorized pool professionals.
Child Safety
Children should not be allowed to operate or perform maintenance on this product. No one, par cularly
children, should sit, step, lean, or climb on any of your pools opera onal system. In the interests of child
safety, all components of a pool’s opera onal system should be located at least 3.5 metres away from
the pool to meet Australian Standards.
Electrical Hazard
Should a lack of water be detected, the unit’s electronic fl ow switch is designed to turn off the system.
Interfering with the electronic ow switch could result in personal injury and/or damage to the cell.
One pump per electrical socket only (no ancillary equipment should be connected to the same outlet).
This outlet is rated for pumps up to 2HP maximum. This appliance is not intended for use by persons
(including children) with reduced physical, sensory or mental capabili es, or lack of experience and
knowledge, unless they have been given supervision or instruc on concerning use of the appliance by a
person responsible for their safety. Children should be supervised to ensure that they do not play with
the appliance.
Please Note: Australian standards for the installa on of the chlorinator should be carried out by a qualifi ed
person in accordance with the Australian wiring rules AS/NZS 3000. The chlorinator power pack should be
located in the correct pool zone and connected to supply via a power outlet that is protected by a residual
current device (RCD) having a rated residual opera ng current not exceeding 30mA. The power outlet
should have a degree of protec on suitable for the pool zone. Ensure that equipoten al bonding of all parts
of the pool installa on is carried out.
3
Informa on before installa on
Carton Contents:
1 x Power Pack (control box)
1 x Electroly c Cell
1 x Owner/Operators Manual
1 x Installa on Screw Set
1 x Power Pack Hanging Template
Technical specifi ca ons
Power supply voltage 220 - 240 Vac-50 Hz
Electric power Max. 140 W
Protec on index IPX3
Control box size (W x L x D) 285 x 405 x 115 mm
Weight (box + cell) Minimum 7.1 kg
Install the cell
(a) Cell MUST be installed horizontally downstream of the heater and lter. It MUST be the last piece of
equipment in the return line to the pool.
(b) The posi! on of the cell, rela! ve to other equipment, should be such that gases generated under normal
opera! on should not accumulate in any receptacle or pipework. Thus, the cell should be posi! oned in-line
AFTER all receptacles where gases in excess of 2 litres may accumulate under normal opera! on. e.g. lter
tanks, header tanks, solar systems, by-pass pipe loops, heaters, etc.
(c) If a valve is required a" er the cell it should always be a non-return valve not a manually operated version.
Torque = 1.2 N.m (= 12.2 kg.cm)