INSTALLATION INSTRUCTIONS MODELS FRAS50/60/70
READ AND SAVE THESE INSTRUCTIONS.
IMPORTANT SAFEGUARDS.
CAUTION: To reduce the risk of fire and to properly exhaust air, be sure to duct air outside. Do Not vent exhaust air into spaces
within walls or ceilings or into attics, crawl spaces, or garages.
WARNING: To reduce the risk of fire or electric shock, Do Not use this fan with any solid-state speed control device.
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING.
a) Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
b) Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
CAUTION: For general ventilating use ONLY. DO NOT use to exhaust hazardous or explosive materials and vapors.
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING.
a) Installation work and electrical wiring must be done by a qualified person (s) in accordance with all applicable codes and
standards, including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment
to prevent back drafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published
by the National Fire Protection Association (NFPA) and the American Society of Heating, Refrigeration, and Air-Conditioning
Engineers (ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
d) Ducted fans must always be vented to the outdoors.
e) If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a
GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
f) NEVER place a switch where it can be reached from a tub or shower.
IF YOU DISCOVER ANY MISSING COMPONENTS OR DAMAGE CALL 1-800-465-7300 BETWEEN 8:00 AM &
3:30 PM EASTERN TIME MONDAY TO FRIDAY.
________________________________________________________________________
FIGURE 2.
210572083
This fan must be installed as per UL and CUL rated ceiling
assembly (refer to fig. 2). This will require the installation
of a minimum 3/8" fire rated gypsum board under the
subfloor and a minimum 5/8" gypsum board to cover the top
of the fan housing.
To install this fan you will need to remove the fan's blower
assembly. It is secured in place with one screw through the
venturi, once removed you can release the blower from the
lances in the housing and lift the blower out. Place it
somewhere so it does not get damaged.
MOUNTING THE HOUSING. REFER TO FIG. 2.
AS SHOWN BELOW THE CEILING DAMPER FRAME WILL
REQUIRE A CUTOUT OF 7-7/8" x 8". AFTER THE
INSTALLATION IS COMPLETE, SEAL ANY GAPS BETWEEN
THE DAMPER FRAME AND CEILING DRYWALL WITH CAULK
CARRYING THE APPROPRIATE UL RATING.
1. Select the best location to mount the housing in the ceiling. As
per UL and CUL fire resistance construction, install a minimum 3/8"
Fire Rated gypsum board 18" long so that it is centered above the
fan. The gypsum board must span the distance between the joists,
typically 14.5" for joists on 16" centers.
2. Select the most convenient electrical knockout and remove it.
3. Insert the 4 slide rails into the channels on the housing side.
4. Adjust the housing height so the housing will be flush with the
finished ceiling.
5. Secure the 4 slide rails to the joist using wood screws. Make sure
you install a washer at the head of each screw as shown below. This
will ensure the screw head does not slip out of the mounting rail.
DUCTING.
Note: All ducting must comply with local and national building codes.
1. Ensure any tape holding the damper in place is removed and that
the damper is operating freely.
2. Connect the ducting to the fan's duct collar. Secure in place using
duct tape or a screw clamp. Always duct the fan to the outside
through a wall or roof cap.
ELECTRICAL WIRING.
CAUTION: MAKE SURE THE POWER IS TURNED OFF BEFORE
BEGINNING THIS INSTALLATION.
Note: All wiring must comply with local and national codes. You
MUST ground this fan.
1. Run wiring from an approved wall switch carrying the appropriate
rating. One neutral (white), one ground (green or bare copper), and
one hot (black lead connected to the switch). Secure the electrical
FIGURE 1.
wires to the housing using an approved electrical connector. Make sure
you leave enough wiring in the box to make connection to fan's wiring.
2. Connect the white wire to the white wire on the fan's receptacle.
Connect the black wire to the black wire on the fan's receptacle.
Connect the ground from the house to the fan's ground.
3. Retrieve the fan's motor plate removed earlier, reinstall the motor
plate at a 45 degree angle, inserting the side with the two tabs first. The
two tabs will fit into the slots in the fan housing.
4. Secure the fan’s motor plate in place with the screw removed earlier.
5. Spin the fan blade to ensure it moves freely and does not hit anything.
6. Plug the motor into the fan’s receptacle.
COMPLETING THE INSTALLATION.
Once the fan housing has been installed and the ceiling drywall is in place
you can complete the fan’s installation
CEILING DAMPER & GRILL INSTALLATION.
CAUTION: The ceiling damper supplied is spring loaded and has the
potential to release suddenly when handled improperly. A damaged
spring or defective fusible link can allow the damper to close violently
into the handler's hand or arm, causing serious injury. Care should be
exercised when handling and installing spring loaded dampers. It is
recommended that gloves be worn by handlers and installers.
The ceiling damper supplied with the unit is designed to install only in Air-
King Model AKFH1 housings.
1. Install the ceiling damper & ceiling damper frame into the opening of
the fan housing. The ceiling damper frame is designed to fit on the
outside of the housing and the ceiling damper will sit on the inside of
the fan housing.
2. Once positioned in place secure the ceiling damper frame to the fan
housing using two of the supplied #8 x 1" screws. Carefully drive the
screws through the two oblong slots on the ceiling damper frame into the
screw retaining lances on each side of the fan housing. Complete this
step slowly as you do not want to damage the lances on the housing.
3. Once the ceiling damper is installed and secure, position the metal fan
grill in place aligning the two holes in the grill with the two extruded holes
on the ceiling damper frame. Use the remaining two #8 x 1" screws to
secure the grill onto the fan.
CARE AND MAINTENANCE
CAUTION - BEFORE CLEANING OR SERVICING TURN OFF THE POWER
TO THE FAN.
1. Clean the grill using a mild soap or detergent only, no abrasives.
2. The fan motor is permanently lubricated, DO NOT oil the motor.
3. Once a year it is a good idea to inspect and clean the internal parts of
the fan, over time debris will build up on the fan blade causing the motor
to work harder than it should. When cleaning the internal parts be
extremely careful working around the spring loaded ceiling damper. Wear
gloves and use a vacuum with an extension hose to clean inside the fan.
RECTANGULAR SECTION OF 3/8" FIRE RATED GYP
BOARD MINIMUM 18" LONG BY WIDTH OF JOIST
SPACE (SEE #1: INSTALLATION LOCATION).
SEE DETAILS ON UL CLASSIFICATION
MARKING ON ENCLOSED PRODUCT
LIMITED WARRANTY
WHAT THIS WARRANTY COVERS: This product is warranted against defects in workmanship and/or materials.
HOW LONG THIS WARRANTY LASTS: This warranty extends only to the original purchaser of the product and lasts for five (5) years from the date of original purchase or until the
original purchaser of the product sells or transfers the product, whichever first occurs.
WHAT AIR KING WILL DO: During the warranty period, Air King will, at its sole option, repair or replace any part or parts that prove to be defective or replace the whole product with the
same or comparable model.
WHAT THIS WARRANTY DOES NOT COVER: This warranty does not apply if the product was damaged or failed because of accident, improper handling or operation, shipping damage,
abuse, misuse, unauthorized repairs made or attempted. This warranty does not cover shipping costs for the return of products to Air King for repair or replacement. Air King will pay
return shipping charges from Air King following warranty repairs or replacement
ANY AND ALL WARRANTIES, EXPRESSED OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY), LAST ONE YEAR FROM THE DATE
OF ORIGINAL PURCHASE OR UNTIL THE ORIGINAL PURCHASER OF THE PRODUCT SELLS OR TRANSFERS THE PRODUCT, WHICHEVER FIRST OCCURS AND IN NO EVENT SHALL
AIR KING’S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE (I) INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER, OR (II)
REPLACEMENT OR REPAIR OF ANY HOUSE FUSES, CIRCUIT BREAKERS OR RECEPTACLES. NOTWITHSTANDING ANYTHING TO THE CONTRARY, IN NO EVENT SHALL AIR KING’S
LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY EXCEED THE PURCHASE PRICE OF THE PRODUCT AND ANY SUCH LIABILITY SHALL TERMINATE UPON THE EXPIRATION
OF THE WARRANTY PERIOD.
Some states and provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so these exclusions or
limitations may not apply to you. This warranty gives you specific legal rights. You may also have other rights which vary from state to state and province to province. Proof of purchase is
required before a warranty claim will be accepted.
CUSTOMER SERVICE:
Toll-Free (800) 465-7300
Our Customer Service team is available to assist you with product questions, service center locations, and replacement parts. They can be reached Monday through Friday, 8am-4pm
Eastern. Please have your model number available, as well as the type and style (located on the label inside of your product).Please do not return product to place of purchase.
www.airkinglimited.com
PARTS FOR DISCONTINUED, OBSOLETE AND CERTAIN OTHER PRODUCTS MAY NOT BE AVAILABLE. DUE TO SAFETY REASONS, MANY ELECTRONIC COMPONENTS AND MOST
HEATER COMPONENTS ARE NOT AVAILABLE TO CONSUMERS FOR INSTALLATION OR REPLACEMENT.
Especificaciones del producto
Marca: | Air King |
Categoría: | campana extractora |
Modelo: | FRAS70 |
¿Necesitas ayuda?
Si necesitas ayuda con Air King FRAS70 haz una pregunta a continuación y otros usuarios te responderán
campana extractora Air King Manuales
16 Octubre 2024
19 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
campana extractora Manuales
- campana extractora Candy
- campana extractora Electrolux
- campana extractora Samsung
- campana extractora ATAG
- campana extractora Bosch
- campana extractora AEG
- campana extractora IKEA
- campana extractora Panasonic
- campana extractora AEG Electrolux
- campana extractora Bauknecht
- campana extractora BEKO
- campana extractora Delonghi
- campana extractora Etna
- campana extractora Grundig
- campana extractora Honeywell
- campana extractora Indesit
- campana extractora Inventum
- campana extractora Miele
- campana extractora Siemens
- campana extractora Whirlpool
- campana extractora Zanussi
- campana extractora Zanker
- campana extractora Acec
- campana extractora Amica
- campana extractora Amana
- campana extractora Ardo
- campana extractora Arcelik
- campana extractora Asko
- campana extractora Silverline
- campana extractora Bartscher
- campana extractora GE
- campana extractora Orbegozo
- campana extractora Sharp
- campana extractora Fisher And Paykel
- campana extractora Bertazzoni
- campana extractora Lamona
- campana extractora Klarstein
- campana extractora Fagor
- campana extractora Brandt
- campana extractora Omega
- campana extractora Smeg
- campana extractora Gorenje
- campana extractora Neff
- campana extractora Baumatic
- campana extractora Hoover
- campana extractora Saturn
- campana extractora KitchenAid
- campana extractora Teka
- campana extractora Progress
- campana extractora Cata
- campana extractora Gaggenau
- campana extractora Hotpoint-Ariston
- campana extractora Ignis
- campana extractora Kernau
- campana extractora Maytag
- campana extractora Thermador
- campana extractora Hanseatic
- campana extractora Vox
- campana extractora Cylinda
- campana extractora Bestron
- campana extractora Bellini
- campana extractora Westinghouse
- campana extractora Vestel
- campana extractora ECG
- campana extractora Pelgrim
- campana extractora Blomberg
- campana extractora Itho
- campana extractora Russell Hobbs
- campana extractora Elica
- campana extractora Constructa
- campana extractora BlueStar
- campana extractora Summit
- campana extractora Hotpoint
- campana extractora Midea
- campana extractora De Dietrich
- campana extractora Junker
- campana extractora Blaupunkt
- campana extractora Concept
- campana extractora Gram
- campana extractora Monogram
- campana extractora Frigidaire
- campana extractora Svan
- campana extractora Logik
- campana extractora Balay
- campana extractora PKM
- campana extractora Frilec
- campana extractora Rosieres
- campana extractora Scholtes
- campana extractora Profilo
- campana extractora KKT Kolbe
- campana extractora Berg
- campana extractora CDA
- campana extractora Imperial
- campana extractora Heinner
- campana extractora Schneider
- campana extractora Kenmore
- campana extractora Philco
- campana extractora Weller
- campana extractora Juno
- campana extractora Guzzanti
- campana extractora Defy
- campana extractora Infiniton
- campana extractora Blanco
- campana extractora Orima
- campana extractora Nordmende
- campana extractora Falmec
- campana extractora Haier
- campana extractora Rangemaster
- campana extractora Boretti
- campana extractora Ariston Thermo
- campana extractora Viking
- campana extractora Eico
- campana extractora Wolkenstein
- campana extractora Hansa
- campana extractora Thor
- campana extractora Exquisit
- campana extractora Elba
- campana extractora Proline
- campana extractora Euromaid
- campana extractora Corberó
- campana extractora Zelmer
- campana extractora Kelvinator
- campana extractora Mora
- campana extractora Soler And Palau
- campana extractora Steel Cucine
- campana extractora Zephyr
- campana extractora Bomann
- campana extractora Novy
- campana extractora Kuppersbusch
- campana extractora Continental Edison
- campana extractora Jenn-Air
- campana extractora Limit
- campana extractora Freggia
- campana extractora Edesa
- campana extractora Franke
- campana extractora New World
- campana extractora AYA
- campana extractora Leisure
- campana extractora Nodor
- campana extractora Jocel
- campana extractora Glem Gas
- campana extractora Viva
- campana extractora Respekta
- campana extractora M-System
- campana extractora Rex
- campana extractora Meireles
- campana extractora Dacor
- campana extractora Falcon
- campana extractora Technika
- campana extractora Airforce
- campana extractora V-Zug
- campana extractora Sauber
- campana extractora MPM
- campana extractora Becken
- campana extractora Esatto
- campana extractora Belling
- campana extractora Mx Onda
- campana extractora Tesy
- campana extractora Kleenmaid
- campana extractora Privileg
- campana extractora Vivax
- campana extractora Stoves
- campana extractora Faber
- campana extractora Ilve
- campana extractora Caple
- campana extractora Eurotech
- campana extractora Wolf
- campana extractora Thermex
- campana extractora Kunft
- campana extractora Mepamsa
- campana extractora Upo
- campana extractora Rommer
- campana extractora ZLine
- campana extractora Belion
- campana extractora Unox
- campana extractora Scancool
- campana extractora Sauter
- campana extractora Lynx
- campana extractora Barazza
- campana extractora Broan
- campana extractora Cecotec
- campana extractora Arctic Cooling
- campana extractora Toolcraft
- campana extractora Marynen
- campana extractora Axiair
- campana extractora La Germania
- campana extractora Gutmann
- campana extractora Roblin
- campana extractora Oranier
- campana extractora Tisira
- campana extractora Bielmeier
- campana extractora Turbo Air
- campana extractora Schweigen
- campana extractora Apelson
- campana extractora Dominox
- campana extractora Witt
- campana extractora Foster
- campana extractora Everdure
- campana extractora Piccante
- campana extractora Kucht
- campana extractora Signature
- campana extractora Helios
- campana extractora JennAir
- campana extractora Flama
- campana extractora LERAN
- campana extractora Best
- campana extractora Halifax
- campana extractora Elin
- campana extractora Fulgor Milano
- campana extractora High One
- campana extractora Whispair
- campana extractora Linarie
- campana extractora XO
- campana extractora K&H
- campana extractora Artusi
- campana extractora Robinhood
- campana extractora Sirius
- campana extractora Sôlt
- campana extractora Chef
- campana extractora Cosmo
- campana extractora ARC
- campana extractora Emilia
- campana extractora Ciarra
- campana extractora Royal Catering
- campana extractora Cookology
- campana extractora Sedona
- campana extractora Vitrokitchen
- campana extractora Euro Appliances
- campana extractora Arthur Martin-Electrolux
- campana extractora NuTone
- campana extractora Elektra Bregenz
- campana extractora InAlto
- campana extractora CENDO
- campana extractora Porter & Charles
- campana extractora Café
- campana extractora Classique
- campana extractora Applico
- campana extractora Venmar
- campana extractora Twin Eagles
- campana extractora Airone
- campana extractora Kluge
- campana extractora Trade-Wind
- campana extractora Mayer
- campana extractora Vent-A-Hood
- campana extractora HomeCraft
- campana extractora CEEM
- campana extractora Pitsos
Últimos campana extractora Manuales
27 Octubre 2024
27 Octubre 2024
27 Octubre 2024
27 Octubre 2024
27 Octubre 2024
27 Octubre 2024
27 Octubre 2024
25 Octubre 2024
24 Octubre 2024
24 Octubre 2024