Alula RE119 Manual de Usario

Lee a continuación 📖 el manual en español para Alula RE119 (2 páginas) en la categoría No categorizado. Esta guía fue útil para 2 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/2
Use the panel installation guide to verify proper system setup.
The Home Disaster is an integrated environmental sensor
that detects ood and extreme temperature conditions.
Features
Titanium probes for unmatched corrosion immunity
Detects ood, freeze, and heat conditions
Secure encrypted wireless transmissions
5-year warranty
Enroll the ood sensor (rst ID) by placing the panel into
wireless enrollment mode and then sending an enrollment
signal from the sensor.
Options for Sending an Enrollment Signal
Remove the battery tab and cover to trip tamper.
Freeze & heat inputs must be enabled as additional
zones to function. Activate only the zones needed in
order to extend battery life.
To activate and enroll a freeze input (second ID):
Remove magnet from reed switch
Hold down tamper and install battery
To activate and enroll a heat input (third ID):
Have magnet next to reed switch
Hold down tamper and install battery
Install by placing the remote ood probe in the location
requiring ood or leak detection. If desired, the ood
probe can be screwed to the oor or baseboard. Next,
mount the sensor to the wall using the mounting screw
locations. Finally, connect the ood probe wires to the
sensor’s terminal blocks.
Detects water pooled under the sensor and reports extreme
temperature conditions.
Default Temperature Trip Points
Heat alarms when over 100°F (38°C)
Heat restores when under 97°F (36°C)
Freeze alarms when under 45°F (7°C)
Freeze restores when over 48°F (9°C)
RE119 Home Disaster
Interlogix® Compatible
I
N
S
T
A
L
L
G
U
I
D
E
I
Mounting
Screw
Holes
Wire
Entry
Hole
Resolution Compatibles
IC NOTICE
This device complies with Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including interference
that may cause undesired operation of the device.
Le présent appareil est conforme aux cnr d’Industrie Canada
applicables aux appareils radio exempts de licence. L’exploitation
est autorisée aux deux conditions suivantes:
(1) L’appareil ne doit pas produire de brouillage, et
(2) L’utilisateur de l’appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
IC: 8310A-RE101
WARRANTY
Alula will replace all non-portable products that are defective in
their rst ve (5) years, and all portable products that are defective
in their rst two (2) years.
FCC NOTICE
This device complies with Part 15 of the FCC rules. Operation is
subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference that may be received,
including interference that may cause undesired operation.
Changes or modications not expressly approved by Alula could void
the user’s authority to operate this equipment.
FCC ID: U5X-RE101
TRADEMARKS
Alula is a trademark owned by Alula Holdings, LLC.
“Interlogix” is a trademark owned by United Technologies Electronic
Controls Inc. Alula products will function with Interlogix systems.
However, no Alula product is produced by, endorsed by, or is
ofcially associated with Interlogix. Alula recommends verifying
proper enrollment and operation, per control panel installation
instructions, at installation.
Panasonic is a registered trademark owned by Panasonic
Corporation.
Pro Tips
Both titanium probes must be in the same puddle for the sensor to detect water.
A second probe can be added for additional protection in another location. Do not
install more than two probes.
The ood probe can be mounted in a sump tank at the desired height to provide pump
failure notication.
47-0021-01 • REV B • 2019-02-07
Tech Support Line • (888) 88-ALULA • (888) 882-5852
alula.net
Physical
Housing Dimensions
Weight with Battery
Mounting Fastener
3.25 x 1.40 x 1.05 inches (8.3 x 3.6 x 2.7 cm)
1.90 ounces (54 grams)
#4 or #6 screws (not provided)
Environmental
Operating Temperature
Maximum Humidity
32 to 120 °F (0 to 49 °C)
85% non-condensing relative humidity
Sensor Specications
Frequency
Replacement Battery
Nominal Battery Life
Battery Voltage
Current Draw
Transmitted Indications
Temperature Accuracy
319.5 MHz
One Panasonic® CR123A
8 to 10 years
3.0 VDC (Nominal), 2.2 VDC (Low)
20 mA (Maximum), 0.6 uA (Quiescent)
Flood, Freeze, Heat, Tamper, Low Battery, Supervision
+/- 2°C
Certication
RE119 FCC, IC
Specications subject to change without notice.
Specications
00
00

Especificaciones del producto

Marca: Alula
Categoría: No categorizado
Modelo: RE119

¿Necesitas ayuda?

Si necesitas ayuda con Alula RE119 haz una pregunta a continuación y otros usuarios te responderán




No categorizado Alula Manuales

Alula

Alula RE118 Manual de Usario

11 Septiembre 2024
Alula

Alula RE605 Manual de Usario

11 Septiembre 2024
Alula

Alula RE619 Manual de Usario

11 Septiembre 2024
Alula

Alula RE305 Manual de Usario

11 Septiembre 2024
Alula

Alula RE219 Manual de Usario

11 Septiembre 2024
Alula

Alula RE318 Manual de Usario

11 Septiembre 2024
Alula

Alula RE105 Manual de Usario

11 Septiembre 2024
Alula

Alula RE205 Manual de Usario

11 Septiembre 2024
Alula

Alula RE218 Manual de Usario

11 Septiembre 2024
Alula

Alula RE119 Manual de Usario

11 Septiembre 2024

No categorizado Manuales

Últimos No categorizado Manuales