Antec Attache PID-100 Manual de Usario
Lee a continuación 📖 el manual en español para Antec Attache PID-100 (6 páginas) en la categoría Escáner. Esta guía fue útil para 2 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/6
3
Attaché User's Manual (English)
Trademarks
IBM, PC and VGA are registered trademarks of International Business
Machines Corporation.
MMX is a registered trademark of Intel Corporation.
MS-DOS, Windows, Windows 95, Windows 98, Windows NT and
Microsoft are registered trademarks of Microsoft Corporation.
All other trademarks are the properties of their respective owners.
Contents
- Installation and Calibration
- Pre-defined Setting
- Custom Setting
- Information Window
DECLARATION OF CONFORMITY
We Antec Incorporated, 47900 Fremont Blvd. Fremont, CA 94538 USA,
Telephone: 510-770-1200, declare under our sole responsibility that the product
complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) This device may not cause harmful interference and (2) this device must
accept any interference that may cause undesired operation.
PID-100
2
Note : This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
• Reorient the receiving antenna.
• Increase the separation between the equipment and receiver.
• Move scanner away from the receiver.
• Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
9. Attaché set-up is now complete. You may begin to scan images now.
54
Installation and Calibration
1. Insert the CD>select CD device>run Setup.
2. Follow the installation instructions.
3. Connect the Attaché with the PCMCIA interface card.
4. Insert the card into the PCMCIA slot on your notebook or PCMCIA
device on your desktop computer. (such as Antec Datachute)
5. Run PageManager or other applications which are TWAIN compliant.
Your Windows98 has a built in program "Imaging" which is TWAIN
compliant. Go[Start]>[Programs]>[Accessories]>[Imaging] to run the
program.
6. Use the pull-down menu from [File]>Click [Select Source] and select
[Antec] as the device source.
7. Click [Acquire] to enable Attaché. A window with the title "Pre-defined
Setting" will appear on your screen with the "Calibration Page" window
on top of it.
8. Insert the calibration sheet into the Attaché as instructed to set up the
calibration data. This is for the first time on your computer. To make
sure you can always get the best image, this "Calibration Page" will
appear periodically to remind you to calibrate your computer. You can
always click on "Custom Setting" button to enter the setting window
and click on "Calibrate" button to set up the calibration at any time
you want.
Note: Insert the paper to the side with arrow marks on the Attaché.
7
• [Fax] Mode
Fax mode is the best choice to scan documents to be faxed. It scans in
200dpi black/white, A4 size {8.3² x 11.7²}
• [E-Mail] Mode
It scans in 150 dpi gray, A4 size {8.3² x 11.7²}
• [OCR] Optical Character Recognition Mode
To scan documents to be processed by OCR software and convert
them into editable text. It scans in 300dpi black/white, letter size
{8.5² x 11.0²}
• [Photo] Mode
To scan color photos or graphics in 150dpi Color, photo size {3.0² x 5.0²}
• [Magazine] Mode
To scan pictures from magazines, books or other printed materials, use
Magazine mode. It scans in 75dpi Color, A4 size {8.3² x 11.7²} with
"Descreen" filter applied to remove the moiré pattern.
Note: If these pre-defined settings do not meet your scanning needs, you
can right click the icon you want to change to modify pre-setting
values or use "Custom Setting" window to fine-tune your scanning
parameters.
6
Pre-defined Setting
Whenever you click [Acquire] from the pull down menu, the "Pre-defined
Setting" window will appear. Insert the document to the side with arrow
marks on the Attaché.
Attaché provides 5 predefined scanning settings for different purposes. To
begin scanning, you need to choose the setting by clicking on the icon.
Especificaciones del producto
Marca: | Antec |
Categoría: | Escáner |
Modelo: | Attache PID-100 |
¿Necesitas ayuda?
Si necesitas ayuda con Antec Attache PID-100 haz una pregunta a continuación y otros usuarios te responderán
Escáner Antec Manuales
7 Septiembre 2024
Escáner Manuales
- Escáner HP
- Escáner Panasonic
- Escáner Epson
- Escáner Medion
- Escáner Nikon
- Escáner Xerox
- Escáner Canon
- Escáner Albrecht
- Escáner Reflecta
- Escáner Avision
- Escáner Brother
- Escáner Lenco
- Escáner Tevion
- Escáner Renkforce
- Escáner Kodak
- Escáner Targus
- Escáner Trust
- Escáner Easypix
- Escáner Maginon
- Escáner GlobalTronics
- Escáner Fujitsu
- Escáner Genius
- Escáner Uniden
- Escáner Ion
- Escáner Ricoh
- Escáner Minolta
- Escáner Veho
- Escáner Rittz
- Escáner Jobo
- Escáner Plustek
- Escáner Traveler
- Escáner Mustek
- Escáner Elmo
- Escáner RadioShack
- Escáner ICarsoft
- Escáner Kenko
- Escáner Kogan
- Escáner Panduit
- Escáner Newland
- Escáner Vupoint Solutions
- Escáner DTRONIC
- Escáner IRIS
- Escáner Cartrend
- Escáner 3DMAKERPRO
- Escáner Neat
- Escáner Ambir
- Escáner Visioneer
- Escáner Microtek
Últimos Escáner Manuales
27 Octubre 2024
22 Octubre 2024
22 Octubre 2024
21 Octubre 2024
19 Octubre 2024
17 Octubre 2024
17 Octubre 2024
16 Octubre 2024
15 Octubre 2024
11 Octubre 2024