INSTALLATION INSTRUCTIONS •
ISTRUZIONI D’INSTALLAZIONE
NOTICE D’INSTALLATION •
INSTALLATIONSANLEITUNGEN
INSTRUCCIONES DE INSTALACION •
INSTRUÇÕES DE INSTALAÇÃO
OODDHHGGIIEESS TTOOPPOOQQEETTHHSSHHSS
37.4255.124.01 02/2017
Split air conditioner system •
Condizionatore d’aria split system
Climatiseurs split •
Split-klimagerät
Acondicionador de aire de consola partida sistema split •
Aparelho de ar condicionado-Sistema Split
ΔΙΑΙΡΟΥΜΕΝΕΣ ΜΟΝΑΔΕΣ ΚΛΙΜΑΣΜΟΥ
AEI1G65EMX
AEI1G65EMX3PH GR
2
IMPORTANT!
Please read before installation
This air conditioning system meets strict safety and operating
standards.
For the installer or service person, it is important to install or
service the system so that it operates safely and efficiently.
For safe installation and trouble-free operation, you must:
Carefully read this instruction booklet before beginning.
Follow each installation or repair step exactly as shown.
Observe all local, state and national electrical codes.
Pay close attention to all warning and caution notices given in
this manual.
•The unit must be supplied with a dedicated electrical line.
This symbol refers to a hazard or unsafe practice which can result
in severe personal injury or death.
This symbol refers to a hazard or unsafe practice which can result
in personal injury or product or property damage.
If necessary, get help
These instructions are all you need for most installation sites and
maintenance conditions.
If you require help for a special problem, contact our sale/service
outlet or your certified dealer for additional instructions.
In case of improper installation
The manufacturer shall in no way be responsible for improper
installation or maintenance service, including failure to follow the
instructions in this document.
SPECIAL PRECAUTIONS
During installation, connect before the refrigerant system and
then the wiring one; proceed in the reverse orden when removing
the units.
When wiring
ELECTRICAL SHOCK CAN CAUSE SEVERE
PERSONAL INJURY OR DEATH. ONLYA QUALIFIED,
EXPERIENCED ELECTRICIANS SHOULD ATTEMPT
TO WIRE THIS SYSTEM.
Do not supply power to the unit until all wiring and tubing are
completed or reconnected and checked, to ensure the grounding.
Highly dangerous electrical voltages are used in this system.
Carefully refer to the wiring diagram and these instructions when
wiring.
Improper connections and inadequate grounding can cause
accidental injury and death.
Ground the unit following local electrical codes.
The Yellow/Green wire cannot be used for any connection
different from the ground connection.
Connect all wiring tightly. Loose wiring may cause overheating
at connection points and a possible fire hazard.
Do not allow wiring to touch the refrigerant tubing, compressor,
or any moving parts of the fan.
Do not use multi-core cable when wiring the power supply and
control lines. Use separate cables for each type of line.
When transporting
Be careful when picking up and moving the indoor and outdoor
units. Get a partner to help, and bend your knees when lifting to
reduce strain on your back. Sharp edges or thin aluminium fins on
the air conditioner can cut your fingers.
When installing...
... In a ceiling or wall
Make sure the ceiling/wall is strong enough to hold the unit-weight.
It may be necessary to build a strong wooden or metal frame to
provide added support.
... In a room
Properly insulate any tubing run inside a room to prevent
"sweating", which can cause dripping and water damage to walls
and floors.
... In moist or uneven locations
Use a raised concrete base to provide a solid level foundation for
the outdoor unit.
This prevents damage and abnormal vibrations.
... In area with strong winds
Securely anchor the outdoor unit down with bolts and a metal
frame. Provide a suitable air baffle.
... In a snowy area (for heat pump-type systems)
Install the outdoor unit on a raised platform that is higher than
drifting snow. Provide snow vents.
When connecting refrigerant tubing
Keep all tubing runs as short as possible.
Use the flare method for connecting tubing.
Apply refrigerant lubricant to the matching surfaces of the flare
and union tubes before connecting them; screw by hand and
then tighten the nut with a torque wrench for a leak-free
connection.
Check carefully for leaks before starting the test run.
NOTE:
Depending on the system type, liquid and gas lines may be either
narrow or wide. Therefore, to avoid confusion, the refrigerant
tubing for your particular model is specified as narrow tube for
liquid, wide tube for gas.
When servicing
Turn the power OFF at the main power board before opening
the unit to check or repair electrical parts and wiring.
Keep your fingers and clothing away from any moving parts.
Clean up the site after the work, remembering to check that no
metal scraps or bits of wiring have been left inside the unit being
serviced.
Ventilate the room during the installation or testing the
refrigeration system; make sure that, after the installation, no gas
leaks are present, because this could produce toxic gas and
dangerous if in contact with flames or heat-sources.
WARNING
CAUTION
WARNING
EG
3
Installation site selection
AVOID
Heat sources, exhaust fans.
Direct sunlight.
Damp, humid or uneven locations.
To make holes in areas where electrical wiring or conduits
are located.
DO
Choose places as cool as possible and well ventilated.
use lug bolts or equal to bolt down the unit, reducing
vibration and noise.
Provide a solid base for outdoor unit raised from the ground
level. Fix unit to base using 4 anchor bolts.
EG
10 cm
10 cm
40 cm
SYSTEM WIRING DIAGRAM
2 INDOOR UNITS
1 INDOOR UNIT
1 PHASE
1 PHASE

Especificaciones del producto

Marca: Argo
Categoría: Varios controles climáticos
Modelo: AEI1G65EMX3PH
Tipo de operación: Knoppen
Color del producto: Zwart
Peso.: 3701 g
Ancho: 274 mm
Profundidad: 437.8 mm
Altura: 43.9 mm
Peso del embalaje: 4749 g
Ancho del embalaje: 495 mm
Empaquetadura en profundidad: 170 mm
Altura del embalaje: 100 mm
Material de la carcasa: Metaal
País de origen: China
Puerto(s) VGA (D-Sub): 1
Consumo de energía (máx.): 33 W
HDCP: Ja
Velocidad máxima de actualización: 30 Hz
Número de puertos de entrada HDMI: 1
Número de DisplayPorts: 1
Voltaje de entrada: 100 - 240 V
Conector de 3,5 mm: Ja
Temperatura de almacenamiento: -20 - 60 °C
Frecuencia: 50 - 60 Hz
Cantidad de puertos RJ-45: 1
Puertos de salida RJ-45: 1
Versión HDCP: 1.4/2.2
Número de puertos de salida HDMI: 9
Temperatura de funcionamiento (TT): -1 - 44 °C
Humedad relativa de funcionamiento (VV): 20 - 90 procent
Resoluciones escaladas: 3840 x 2160
Conector RS-232/422: Ja