Astralpool HydroSpin Manual de Usario

Lee a continuación 📖 el manual en español para Astralpool HydroSpin (20 páginas) en la categoría filtro de agua. Esta guía fue útil para 8 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/20
H y d r o S p i n
INSTALLATION AND MAINTENANCE MANUAL
MANUEL D’INSTALLATION ET D’ENTRETIEN
MANUAL DE INSTALACIÓN Y MANTENIMIENTO
MANUALE DI INSTALAZIONE E MANUTENZIONE
EINBAU-UND BETRIEBSANLEITUNG
MANUAL DE INSTRUÇÕES E MANUNTENÇÃO
2
1
2
34
5
ENGLISH
IMPORTANT: The instruction manual you are holding includes essential information on the safety measures to be
implemented for installation and start-up. Therefore, the installer as well as the user must read the instructions before
beginning installation and start-up.
Keep this manual for future reference.
To achieve optimum performance of the HydroSpin, follow the instructions provided below:
1. CONTENTS
Inside the box you will find the following components:
1. HydroSpin
2. Support ring
3. 1” Valve
4. 3 supports
5. Installation and maintenance manual
2. GENERAL CHARACTERISTICS
The HydroSpin has been designed to work in all new and existing water installations.
Installing the HydroSpin in filtration systems from 5 to 30m³/h and up to a maximum pressure of 2.5 bars is
recommended.
The HydroSpin:
Significantly reduces water lost in drainage when cleaning the filters.
Reduces the frequency with which the filtration system is cleaned.
The HydroSpin accumulates the separated solids in its lower part, which are then ejected by opening the purge
valve. This should be opened before the waste surpasses the limit indicated in Fig. 1 - . pag.16
3. INSTALLATION
The HydroSpin should be installed between the pump and the filter.
Ensure there is a drain in the area where the HydroSpin is located.
Ensure that the HydroSpin is installed on a horizontal surface.
There should be sufficient space around the HydroSpin to carry out the
inspections and maintenance that will be necessary during its lifetime.
Wall Installation:
1. 47158 The 2 flanges for tube DN250 Kit (cod. ) should be
purchased in advance.
2. Install the flanges on the wall in their final position, with a distance
of 95mm between flanges..
3. Place the HydroSpin on the corresponding support.
4. Screw the flanges on.
5. Join simple or 3 piece 63 in the HydroSpin unions of Ø
entrance and exit (Fig. 3 - pag.16).
6. Using valves in both the entrance and exit is
recommended.
7. Thread the purge valve into the lower part of the
HydroSpin, putting teflon in the thread. Check that it is
closed.
8. Join tubing from the HydroSpin purge, to drainage (Fig. 4
- . pag.16)
9. Installation of a manometer in the HydroSpin inlet is
recommended. (Fig. 5 - . pag.16)
10. Switch on the pump.
3
Three support installation:
1. Fit the three supports on the support ring. (Fig. 2 - . pag.16)
2. Put the HydroSpin on the support ring in its final position.
3. Follow on from point 5 in the previous section.
Note: an electrovalve may be connected to the purge exit in order to temporize cleanings.
4. MAINTENANCE
Purging: before the limit set out in Fig. 1 - pag.16 is reached, the HydroSpin should be purged by opening the
lower valve when accumulated waste can be seen.
When carrying out this operation it is neither necessary to stop the filter system nor to turn the filter valve key.
5. TROUBLE- SHOOTING
If you notice that the pressure reading has risen considerably on the HydroSpin entrance manometer, it may be due
to:
a) The filter is dirty: check the pressure of the filter's manometer, and if it has risen, carry out its cleaning
operation. (Follow the steps in the filter's instruction manual). Afterwards, check that the HydroSpin's
entrance manometer pressure has decreased.
b) The HydroSpin is blocked: check the pressure of the Filter's
manometer, if this is the same or the pressure has decreased, it
means that there is one or more blockages within the HydroSpin, in
which case the following steps must be taken to unblock it:
1. Stop the filtration system.
2. Shut off the system's suction and discharge valves.
3. Purge the waste and water by opening the lower valve.
4. Unscrew the two nuts in the two caps. Take off the two caps.
5. Separate the central body, taking care with the two joints.
6. Unscrew the three screws in the lower part to separate the Water
Distributor and the water brake from th d isc e main body.
7. Check whether any cyclone (hole) is blocked and wash the whole
part with pressurized water, plus all other cyclones.
8. Once everything has been washed, assemble the pieces in
reverse order to that described above, placing the two joints
properly in their places and screwing up the nuts tightly.
Attention:
When it is running check that the HydroSpin does not lose water through
the caps.
Check that the pressure on both the HydroSpin and Filter manometers is sim . ilar
6. SAFETY WARNINGS
Do not install HydroSpin in facilities with a cleaning system with active oxygen or its derivates.
Do not connect the HydroSpin directly to the water network as the pressure may be very high and exceed the
maximum pressure supported by the equipment.
Do not use the filtration circuit for filling up and regulating the swimming pool water level. An error in its use
could cause overpressure in the filter.
Do not clean the equipment with any kind of solvent, as it could lose its
properties (shine, transparency...)
In filtr ation installations with diatomeaceous filters, a bypass between the
pump and the filter must be made so that the HydroSpin does not separate
the diatomeaceous earth when it is introduced into the filtration system; the
when doing so close the connections to the HydroSpin.

Especificaciones del producto

Marca: Astralpool
Categoría: filtro de agua
Modelo: HydroSpin

¿Necesitas ayuda?

Si necesitas ayuda con Astralpool HydroSpin haz una pregunta a continuación y otros usuarios te responderán




filtro de agua Astralpool Manuales

filtro de agua Manuales

Últimos filtro de agua Manuales