Baracuda Hydra+ Manual de Usario

Baracuda Pompa Hydra+

Lee a continuación 📖 el manual en español para Baracuda Hydra+ (14 páginas) en la categoría Pompa. Esta guía fue útil para 5 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/14
H0761800_REVA
HYDRA+ SINGLE SPEED
Installation & Operating Instructions
Baracuda® Hydra+ Single Speed | Installation and Operating Instructions
2
Refer to the following websites for information on warranty and service in your country:
Australia, NZ, Asia and South Pacific go to www.baracuda.com.au
Date of Installation ____________________
Installer Information _____________________________________________________________
Initial Pressure Gauge Reading (with clean filter) ___________________________________
Pump Model Horsepower __________________________ __________________________
Filter Model ___________________________ _______________________________________
Control Panel Model Serial Number ___________________ ________________________
Notes ___________________________________________________________________________
__________________________________________________________________________________
EQUIPMENT INFORMATION RECORD
Table of Contents
Section 1. Important Safety Instructions 3 .....
Section 2. Installation 7 ......................................
2.1 Location Requirements 7 ...................................
2.2 Hydraulic Connections 7 ....................................
2.3 Electrical Connection 8 .....................................
Section 3. Operation 8 .......................................
3.1 Operating Principle 8 .........................................
3.2 Operating the Pump 8 .......................................
3.3 Priming the Pump 9 ...........................................
Section 4. Maintenance 10 ................................
4.1 Routine Maintenance 10 .....................................
4.2 General Maintenance Information 10 ..............
4.3 Winterising ...................................................... 11
4.4 Servicing ......................................................... 11
Section 5. Repair Parts 11 .................................
Section 6. Troubleshooting 12 ...........................
6.1 Appliance Behaviour 12 ......................................
Section 7. Pump Parts 13 ...................................
Baracuda® Hydra+ Single Speed | Installation and Operating Instructions
3
Section 1. Important Safety Instructions
WARNING
READ AND FOLLOW ALL INSTRUCTIONS
All electrical work must be performed by a licensed electrician and conform to all national,
state, and local codes. When installing and using this electrical equipment, basic safety
precautions should always be followed, including the following:
RISK OF SUCTION ENTRAPMENT HAZARD,
WHICH, IF NOT AVOIDED, CAN RESULT IN
SERIOUS INJURY OR DEATH.
Do not block pump suction, as this can cause severe injury or death. Do not use this pump for
wading pools, shallow pools, or spas containing bottom drains, unless the pump is connected
to at least two (2) functioning suction outlets. Drain covers must be certified to the latest
published edition of ANSI/ASME A112.19.8 or its successor standard ANSI/APSP-16.
In Australia AS1926.3 is also an acceptable standard.
A check valve can interfere with the proper operation of certain Suction Vacuum Release System
(SVRS) products. To avoid possible entrapment hazard, serious injury, or death, make sure to review
the operation/owner's manual of your particular SVRS product before installing the check valve.
To reduce the risk of injury, do not permit children to use this product.
To reduce the risk of property damage or injury, do not attempt to change the backwash
(multiport, slide, or full flow) valve position with the pump running.
Baracuda pumps are powered by a high-voltage electric motor and should be installed by a
licensed or certified electrician or a qualified swimming pool service technician.
The pump is for fixed installations only and to be used in conjunction with swimming
pool equipment (e.g., filters). The pump is to be installed in accordance with the relevant
requirements of the Australian wiring rules AS/NZS 3000. Also refer to the installation
instructions relating to the swimming pool equipment for which the pump will be an integral
part. The pump is to be supplied through a residual current device (RCD) with a rated
residual operating current of 30 mA. If the supply cord is damaged it must be replaced by the
manufacturer or its service agent or similarly qualified person in order to avoid hazard. Only a
qualified person/s, should perform repairs and/or maintenance work on the pump and motor,
including any cabling work to the motor.
Incorrectly installed equipment may fail, causing severe injury or property damage.
Do not connect system to an unregulated city water system or other external source of
pressurized water producing pressures greater than 250 KPA (35 PSI). Trapped air in the
system can cause the filter lid to be blown off, which can result in death, serious personal injury,
or property damage. Be sure all air is out of the system before operating.
To minimize risk of severe injury or death, the lter and/or pump should not be subjected to the piping
system pressurization test. Local codes may require the pool piping system to be subjected to a
pressure test. These requirements are generally not intended to apply to the pool equipment, such as
lters or pumps. Baracuda pool equipment is pressure tested at the factory. If, however, the WARNING
cannot be followed, pressure testing of the piping system must include the filter and/or pump.

Especificaciones del producto

Marca: Baracuda
Categoría: Pompa
Modelo: Hydra+
Color del producto: Zwart
Consumo-anual-de-energía: 46.8 kWu
Peso del embalaje: 6000 g
Clase de eficiencia energética (antigua): B
Manual de usuario: Ja
Interruptor encendido / apagado: Ja
Diagonal de la pantalla: 21.5 "
Resolución: 1920 x 1080 Pixels
Relación de aspecto original: 16:9
red LAN: Nee
Modos de vídeo compatibles: 1080i, 1080p, 480i, 480p, 576p, 720p
Ángulo de visión, horizontal: 170 °
Ángulo de visión, vertical: 160 °
Brillo: 250 cd/m²
Tarjeta de garantía: Ja
Dimensiones del paquete (AnxPrxAl): 617 x 140 x 453 mm
Número de puertos USB 2.0: 1
Número de puertos HDMI: 2
Entrada de audio para PC: Ja
Vídeo de componentes (YPbPr/YCbCr): 1
Puerto DVI: Nee
Altavoces incorporados: Ja
Energía promedio: 6 W
Consumo de energía (en espera): 0.41 W
Número de hablantes: 2
Salidas de auriculares: 1
Formato de señal analógica: PAL BG, SECAM L
tipo HD: Full HD
3D: Nee
Versión HDMI: 1.3
Tiempo de respuesta: 5 ms
Resoluciones de gráficos compatibles: 1920 x 1080 (HD 1080)
Montaje VESA: Ja
Interfaz de montaje en panel: 100 x 100 mm
Profundidad (sin base): 52 mm
Altura (sin base): 365 mm
Ancho (sin base): 548 mm
Diámetro de la pantalla en centímetros.: 55 cm
Entrada de PC (D-Sub): Ja
Interfaz común Plus (CI+): Nee
tipo de sintonizador: Analoog & digitaal
Formato de señal digital: DVB-T
televisión por internet: Nee
Ancho del dispositivo (con soporte): 548 mm
Dispositivo de profundidad (con soporte): 160 mm
Altura del dispositivo (con soporte): 395 mm
Peso (con soporte): 4400 g
Teletexto: Ja
guía de televisión electrónica: Ja
Visualización en pantalla (OSD): Ja
Interfaz común (CI): Nee
Número de puertos RF: 1
Teletekst: 1000 pagina's
Número de puertos SCART: 1
Nombre comercial relación de contraste dinámico: Mega Contrast
Audio digital, conexión coaxial.: 1
Tipo-de-unidad-óptica: CD-R, CD-RW, DVD+R, DVD+RW, DVD-R, DVD-RW
Reproductor de DVD: Ja
Incluye reproductor/grabador de DVD: DVD speler
Filtro de peine: 3D
Mando a distancia incluido: Ja
Wifi.: Nee
voltaje-de-entrada-de-CA: 100 - 240 V
Frecuencia-de-entrada-de-CA: 50 - 60 Hz
Consumo de energía (típico): 30 W
Baterias-incluidas: Ja
Tiempo-de-dormir: Ja

¿Necesitas ayuda?

Si necesitas ayuda con Baracuda Hydra+ haz una pregunta a continuación y otros usuarios te responderán




Pompa Baracuda Manuales

Pompa Manuales