Bionaire BD20 Manual de Usario

Lee a continuación 📖 el manual en español para Bionaire BD20 (14 páginas) en la categoría Humidificador-Deshumidificador. Esta guía fue útil para 10 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/14
English 2
Français/French 6
Svenska/Swedish 10
Norsk/Norwegian 14
Dansk/Danish 18
Suomi/Finnish 22
Holmes Products (Europe) Ltd.
1 Francis Grove
London SW19 4DT
England
Fax: +44 (0)20 8947 8272
Email: enquiriesEurope@jardencs.com
UK - Filter Sales Order Line - 0870 759 9000
Website address: www.bionaire.com/europe
UK - Free phone Customer Service Helpline 0800 052 3615
Holmes Products France
1015, Rue du Maréchal Juin
Z.I Vaux - Le - Pénil
77000 Melun France
Phone: +33 1 64 10 45 80
Fax: +33 1 64 10 02 32
FRANCE - SERVICE CONSOMMATEURS
0 825 85 85 82
© 2011 Sunbeam Products, Inc. doing business as Jarden Consumer Solutions. All rights reserved.
Distributed by Holmes Products (Europe) Ltd., 1 Francis Grove, London SW19 4DT, United Kingdom. Printed in PRC
© 2011 Sunbeam Products, Inc. faisant affaires sous le nom de Jarden Consumer Solutions. Tous droits réservés.
Distribué par Holmes Products (Europe) Ltd., 1 Francis Grove, London SW19 4DT, United Kingdom.
Imprimé en RPC P.N. 149110
SPR 021811-038
INSTRUCTION MANUAL
NOTICE D’UTILISATION
KÄYTTÖOPAS
BRUKERHÅNDBOK
BRUGERVEJLEDNING
BRUKSANVISNING
DIGITAL
DEHUMIDIFIER
MODEL# BD20
pure indoor living
Belgium: +32 38 70 86 86
Czech Republic: +420 48 513 03 03
Denmark: +45 73 33 13 52
Finland: +358 207 599 860
Germany: +49 89 5480195-0
Hungary: +36 40 630-070
Latvia: +371 7514081
Lebanon: +961 1 81 49 46
Lithuania: +370 52 772388
Netherlands: +31 79 36 37 310
Norway: +47 55 11 81 70
Poland: +48 23 662 68 01
Slovakia: +421 41 723 47 09
Spain: +34 902 051 502
Sweden: +46 300567370
Turkey: +90 212 210 99 14
United Arab Emirates: +971 42 97 95 52
32
ENGLISH
PLEASE READ AND SAVE THESE
IMPORTANT INSTRUCTIONS
NOTE: Before reading these
instructions, please review the
corresponding illustrations.
Description of Appliance (See Figure 1)
1. Control Panel
2. Air Oscillator
3. Handle
4. Air Intake Slats
5. Water Reservoir
6. Drain Plug
7. Water Level Pane
8. Drainage Hose
Control Panel (See Figure 2)
A. On/Off Button
B. Auto Button
C. Continuous Operation Button
D. Timer Button
E. Oscillation Button
F. Humidity Control Buttons
LCD Display (See Figure 3)
a. Speed
b. Water Reservoir Full
c. Continuous Dehumidification
d. Timer
e. Oscillation
f. Automatic Defrost
g. Whisper Quiet Automatic Dehumidification
h. Ambient Temperature
i. Automatic Dehumidification
j. Ambient Humidity Level
SAFETY PRECAUTIONS
When using electrical appliances, basic safety
precautions should always be followed to reduce
the risk of fire, electric shock, and injury to
persons, including the following:
1. Read all instructions before using the
appliance.
2. To avoid fire or shock hazard, plug the
appliance directly into an electrical outlet
and fully insert the plug.
3. Keep the cord out of heavy traffic areas. To
avoid fire hazard, NEVER put the cord under
rugs, or near radiators, stoves, or heaters.
4. DO NOT place dehumidifier near heat
sources such as stoves, radiators, and
heaters. Do locate your dehumidifier on an
inside wall near an electrical outlet. The
dehumidifier should be at least 10cm/4”
away from the wall for best results.
5. NEVER drop or insert any object into any
openings.
6. DO NOT operate any appliance with a
damaged cord or plug, after the appliance
malfunctions, or if it has been dropped or
damaged in any manner. Return appliance
to manufacturer for examination, electrical or
mechanical adjustment, or repair.
7. Use appliance only for intended household
use as described in this manual. Any other
use not recommended by the manufacturer
may cause fire, electric shock, or injury
to persons. The use of attachments not
recommended or sold by Holmes Products
(Europe) Ltd. may cause hazards.
8. DO NOT use outdoors.
9. Always place dehumidifier on a firm, flat,
level surface. A waterproof mat or pad is
recommended for under the dehumidifier.
NEVER place it on a surface that may
become damaged by exposure to water and
moisture (i.e. finished floor).
10. Dehumidifier should be unplugged when not
in use.
11. NEVER tilt, move, or attempt to empty unit
while it is operating. Shut off and unplug
before removing the water tank and moving
the unit. DO NOT attempt to remove the
water tank within 15 minutes after the
dehumidifier is turned off and unplugged.
Serious injury may result.
12. This dehumidifier requires regular
maintenance to operate appropriately. Refer
to cleaning and maintenance procedures.
13. NEVER use detergents, petrol, glass cleaner,
furniture polish, paint thinner, or other
household solvents to clean any part of the
dehumidifier.
14. DO NOT attempt to repair or adjust any
electrical or mechanical functions on this
unit. The inside of the unit contains no user
serviceable parts. All servicing should be
performed by qualified personnel only.
15. If the supply cord is damaged, it must be
replaced by the manufacturer or its service
agent or a similarly qualified person.
16. This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities,
or lack of experience and knowledge,
unless they have been given supervision or
instruction concerning use of the appliance
by a person responsible for their safety.
Children should be supervised to ensure that
they do not play with the appliance.
Fig. 1
17. CAUTION: In order to avoid a hazard
due to inadvertent resetting of the thermal
cutout, this appliance must not be supplied
through an external switching device, such
as a timer, or connected to a circuit that is
regularly switched on and off by the utility.
PLEASE SAVE THESE INSTRUCTIONS
Please note that this is an electrical
appliance, and requires attention when
in use.
HOW YOUR DEHUMIDIFIER WORKS
Your Bionaire™ dehumidifier draws moisture
laden air through the intake grill on the top of the
appliance. Humid air passes through refrigerated
coils where the moisture is removed and
collected in the water reservoir.
For optimum performance, it is not
recommended to use this appliance in
environments where the temperature exceeds
37° C or is lower than 5° C.
The unit should only be used indoors in such
areas as a living room or bedroom. Never use
it outdoors. Make sure doors and windows are
closed before using the appliance.
PRE-OPERATING INSTRUCTIONS
1. Select a location for your dehumidifier, on a
flat/level surface, about 10 cm away from the
wall.
2. Place unit on a stable and flat floor surface.
If the floor surface is not even, there is a risk
the unit might be unstable or topple over.
Also, it may result in excessive vibration and
noise.
3. Plug the power cord into electrical outlet.
OPERATING INSTRUCTIONS
Automatic Dehumidifying
1. Plug unit into an appropriate electrical outlet.
The unit will beep 3 times. If open, the air
oscillator will return to its closed position.
2. Press the on/off button to start the unit.
The air oscillator will open to its maximum
position and the unit will start the automatic
dehumidification function.
3. The auto button enables you to select
between automatic dehumidification and
automatic whisper quiet dehumidification.
4. Press the auto button once to switch the
unit between automatic dehumidification and
whisper quiet dehumidification.
5. In automatic dehumidification mode, the
unit will monitor the relative humidity of the
environment and adjust its functionality
accordingly, cycling on and off to maintain
your desired comfort level.
6. In whisper quiet mode, the unit will operate
as in the automatic dehumidification mode
but at low speed. The quiet icon will be
highlighted in the LCD display.
7. The default humidity level is set at 60%
relative humidity (RH). Press the humidity
control buttons up and down to adjust the
humidity level as desired. Please refer to
the humidity control instructions below for
additional operating instructions.
8. To turn the unit off, press the On/Off button
again. The air oscillator will close and the
unit will stop working.
Continuous Dehumidifying
To set the unit to operate continuously, turn the
unit on and then press the continuous operation
button. The unit will operate in high speed, at
60% RH. When you activate this mode, the
continuous icon will be shown in the LCD display.
NOTE: If you adjust the humidity control buttons
during the continuous operation, the unit will
resume the automatic dehumidification mode.
NOTE: If continuous drain function is not in use
and the water reservoir is not manually emptied,
the unit will automatically shut off when the
water reservoir becomes full.
Using The Timer
Once the unit is powered on and an operating
mode is selected, press the timer button
continuously, choosing from 1 to 8 hours as
desired. The timer icon will be highlighted on
the LCD display and show the number of hours
remaining until the unit shuts off.
Oscillating Function
Press the oscillation button to set the air
oscillator to oscillate automatically between
45 and 90 degrees. Press again to select a
stationary position for the air oscillator at the
desired angle between 45 and 90 degrees.
Humidity Control
When the unit starts, the humidity level of the
environment will be shown on the LCD display.
1. For automatic or whisper quiet modes, press
the humidity control buttons to select the
desired humidity level. The control allows
you to adjust level in 5% intervals from 40%
to 80%.
2. If the unit humidity level sensor detects
humidity levels in the environment that are
lower than the selected humidity level, the
compressor will shut off and the fan will
work on low speed. The humidity level of
the environment must be higher than the
humidity level selected in order for the unit to
start operating again.
MODEL# BD20
1
5
B
2
6
C
3
7
D
4
A
8
E
F
Fig. 2 Fig. 3
a
b
h
c
i
d
j
e
f
g
Appliance Cycles On/Off
This is normal operation when using the
automatic dehumidification setting. The
humidistat within the appliance adjusts to
maintain your desired comfort level. To run
continuously, select the continuous mode
(see operating instructions).
Warm Air Coming From Outlet Grill
This is normal operation, caused by heat
exchange while the compressor is on.
GUARANTEE
Please keep your receipt as this will be required
for any claims under this guarantee.
This appliance is guaranteed for 2 years after
your purchase as described in this document.
During this guaranteed period, if in the unlikely
event the appliance no longer functions due to
a design or manufacturing fault, please take
it back to the place of purchase, with your till
receipt and a copy of this guarantee.
The rights and benefits under this guarantee
are additional to your statutory rights, which are
not affected by this guarantee. Only Holmes
Products (Europe) Ltd. (“Holmes”) has the right
to change these terms.
Holmes undertakes within the guarantee period
to repair or replace the appliance, or any part of
appliance found to be not working properly free
of charge provided that:
• youpromptlynotifytheplaceofpurchase
or Holmes of the problem; and
• theappliancehasnotbeenalteredinany
way or subjected to damage, misuse,
abuse, repair or alteration by a person
other than a person authorised by Holmes.
Faults that occur through, improper use,
damage, abuse, use with incorrect voltage,
acts of nature, events beyond the control of
Holmes, repair or alteration by a person other
than a person authorised by Holmes or failure
to follow instructions for use are not covered
by this guarantee. Additionally, normal wear
and tear, including, but not limited to, minor
discoloration and scratches are not covered by
this guarantee.
The rights under this guarantee shall only apply
to the original purchaser and shall not extend to
commercial or communal use.
If your appliance includes a country-specific
guarantee or warranty insert please refer to
the terms and conditions of such guarantee
or warranty in place of this guarantee or
contact your local authorized dealer for more
information.
This marking indicates that this product
should not be disposed with other household
wastes and should be disposed separately
throughout the EU. To prevent possible harm
to the environment or human health from
uncontrolled waste disposal due to the presence
of hazardous substances within
the product, recycle it responsibly
to promote the sustainable reuse
of materials and resources. To
return your used device, please
use the return and collection
systems available to you or
contact the retailer where the
product was purchased. They can take this
product for environmentally safe recycling.
Holmes Products (Europe) Limited
1 Francis Grove
London
SW19 4DT
UK
54
Automatic Defrosting
If the room temperature drops down to 16° C or
lower, the unit’s temperature sensor will set the
compressor to dehumidify for 25 minutes and
then shut off automatically. The fan will keep
running for 7 minutes to defrost in a cycle.
NOTE: When the defrost icon is shown on the
LCD display, the compressor will shut off and the
fan will run at high speed.
Water Full Protection & Auto-Shutoff
When the water reservoir is full, the unit will
sound an alarm beeping 10 times (for about 5
seconds). The water reservoir full icon will be
displayed on the screen and the unit will shut
off automatically. This indicates that it is time to
empty the water reservoir before using the unit
again. Once the empty water reservoir is placed
back into the unit, it will take up to 3 minutes for
the dehumidifier compressor to work again. This
is a protection feature. If you wish to restart the
unit without waiting, unplug it from the electrical
outlet and plug it in again.
Water Drip Protection
When the water reservoir is removed for
emptying, this device will keep the condensed
water that continues to drip. Once the water
reservoir is placed back in the unit, it will release
this water into the reservoir.
Continuous Drainage
For added user convenience, this dehumidifier
includes a hose that can be attached to it to
operate with continuous drainage. To use it,
simply remove the drain plug located in the
back of the unit and connect the PVC hose that
comes with the unit. Find a suitable location for
the unit where the open end of the hose can
drain the outgoing water into an appropriate
receptacle or outside of your home, far enough
away from the foundation to ensure proper
drainage. The unit will now direct water from the
bypass port and through the hose, rather than
into the water reservoir.
NOTE: Please make sure to place the open
end of the hose flat on the ground ensuring it is
not entangled.
CAUTION: The drain hose must be below the
drain plug in order for the unit to drain properly.
NOTE: To help prevent leakage, you should
use a marker to denote the location where the
hose meets the housing on the rear of the unit.
Periodically check to make sure this indicator
has not moved away from the housing to ensure
that your hose will not leak. Leakage inside
the unit will fall into the water reservoir. If this
happens you can empty the water reservoir by
following the instructions above in the “Emptying
the Water Reservoir” section.
CLEANING AND MAINTENANCE
1. Turn the unit off and unplug it from the
electrical outlet.
2. Carefully remove water reservoir to empty it.
Rinse the reservoir with warm water.
3. Use a soft clean cloth to wipe the unit. Do
not use gasoline, paint thinner or other
cleaning products to clean the unit.
4. To clean the mesh filter, carefully remove
the filter and clean it with a vacuum cleaner
or rinse with cool water. Place it in a well-
ventilated location and allow to dry before
replacing filter into unit.
NOTE: Do not expose unit to direct sunlight.
STORAGE INSTRUCTIONS
If you will not be using your dehumidifier for an
extended period of time, please follow these
instructions to properly store it:
1. Turn the dehumidifier off and unplug it from
the electrical outlet.
2. Clean and dry the dehumidifier thoroughly as
per the cleaning instructions above.
3. Make sure all parts are dry before storing.
Do not store the appliance with any water in
the reservoir.
4. Store upright in a cool, dry location.
TROUBLESHOOTING
Malfunctioning Of Compressor
Should the compressor start to malfunction
during the operation, it will automatically
shut off. Wait for 3 minutes and then restart
the unit again. If you wish to restart the unit
without waiting for 3 minutes, unplug it from the
electrical outlet and plug it again.
Protection For Extremely Low Or High
Temperatures
If the unit’s sensor detects the room temperature
is below C or above 40° C, the dehumidifier
will automatically shut off. The unit will signal
with 3 long beep sounds followed by 2 short
ones. To restart the unit it will be necessary to
unplug it from the electrical outlet and plug it
back in.
Failures Of Humidity & Temperature
Sensor
If the sensor malfunctions, the unit will not
operate and the letters “EO” will be displayed
in the screen. You may restart the unit after
troubleshooting.

Especificaciones del producto

Marca: Bionaire
Categoría: Humidificador-Deshumidificador
Modelo: BD20

¿Necesitas ayuda?

Si necesitas ayuda con Bionaire BD20 haz una pregunta a continuación y otros usuarios te responderán




Humidificador-Deshumidificador Bionaire Manuales

Humidificador-Deshumidificador Manuales

Últimos Humidificador-Deshumidificador Manuales