Bionaire BFH3520 Manual de Usario
Bionaire
Calefacción
BFH3520
Lee a continuación 📖 el manual en español para Bionaire BFH3520 (26 páginas) en la categoría Calefacción. Esta guía fue útil para 10 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/26
®
®
9100020007264
BFH3520I06MLM1
BFH3520
2.4KW DIGITAL
TOWER FAN
HEATER
©2006 JCS/THG, LLC
Bionaire®, the Bionaire logoTM and AccuTemp PlusTM are trademarks of JCS/THG, LLC.
Holmes Products (Europe) Ltd
1 Francis Grove
London SW19 4DT
England
Fax: +44 (0)20 8947 8272
Email: info-europe@theholmesgroup.com
UK - Filter Sales Order Line - 0870 759 9000
Website address: www.bionaire.com/europe
UK - Free phone Customer Service Helpline – 0800 052 3615
Holmes Products France
1015, Rue du Maréchal Juin
Z.I Vaux - Le - Pénil
77000 Melun – France
Phone: +33 1 64 10 45 80
Fax: +33 1 64 10 02 32
FRANCE - SERVICE CONSOMMATEURS
Belgium +32 38 70 86 86
Czech Republic +420 48 513 03 03
Denmark +45 45 93 43 73
Finland +358 98 70 870
Greece +30 2 10 61 56 400
Hungary +36 72 482 017
Netherlands +31 079-3637310
Norway +47 51 66 99 00
Poland +48 22 847 8968
Russia +7 095 334 82 21
Spain +34 91 64 27 020
Sweden +46 31 29 09 80
0 825 85 85 82
INSTRUCTION MANUAL
MANUEL D’UTILISATION
BENUTZERHANDBUCH
MANUAL DE INSTRUCCIONES
INSTRUCTIEHANDLEIDING
BRUKSANVISNING
KÄYTTÖOPAS
BRUKERHÅNDBOK
INSTRUKCJA
NÁVOD K OBSLUZE
HASZNÁLATI UTASÍTÁS
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
MANUALE D'USO
MANUAL DE INSTRUÇÕES
English 2
Deutsch/German 5
Français/French 8
Español/Spanish 11
Nederlands/Dutch 14
Svenska/Swedish 17
Suomi/Finnish 20
Norsk/Norwegian 23
Polski/Polish 26
EKKHNIKA/Greek 29
"esky/Czech 32
Magyar/Hungarian 35
PYCCKNÑ/Russian 38
Italiano/Italian 42
Português/Portugese 45
BFH3520
A
B
C
D
E
F
Fig. 1
H
G
I
J
K
L
Fig. 4
Fig. 2
Fig. 3
C
B
D
I
JK
Setting the Off Timer:
1. Select the Mode and/or temperature you wish
the heater to run in.
2. While the heater is running, press and hold
the up (+) and down (-) buttons simultaneously.
3. By pressing the up (+) and down (-) buttons,
program the heater to turn off in up to 16 hours
from the current time, in increments of 1 hour.
4. After setting the timer, the LCD display will
return to show the current room temperature.
An LED will illuminate to show that the timer is
activated.
5. After the predetermined length of time has
passed, the heater will automatically shut off.
Setting the On Timer:
1. While the heater is off, press and hold the up
(+) and down (-) buttons simultaneously.
2. By pressing the up (+) and down (-) buttons,
program the heater to turn on up to 16 hours in
advance of current time, in increments of 1 hour.
3. After the preset length of time has passed, the
heater will automatically turn on Auto Mode HI
Power at 24°C for a preset time of 2 hours.
OSCILLATION INSTRUCTIONS
Press ( ) button J to start and ( ) button J
again to stop oscillation.
REMOTE CONTROL INSTRUCTIONS
Before operation, insert 2 “AAA” batteries (not
included) into the back of the remote control. Remove
batteries before discarding the remote control.
•Do not mix old and new batteries.
•Do not mix alkaline, standard (carbon-zinc), or
rechargeable (nickel-cadmium) batteries.
The remote control for this unit has the capability
of operating all control panel functions (see Fig.
3, 4).
POWER: To turn the unit on press the
Mode ( ) button. To turn the unit off press the
Mode ( ) button.
MODES: To scroll through the various modes
FA, HI, LO, AH, AL and AF press the Mode ( )
Button until you reach your desired setting.
OSCILLATION: To start oscillation, press the
Oscillation ( ) Button once. To stop oscillation
press the button again.
TEMPERATURE:The temperature can be
adjusted only when the unit is set on the Auto
Mode Hi (AH) and Auto Mode Lo (AL).To
increase the temperature setting, press the (+)
button. To decrease the temperature setting that
you desire press the (-) button.
TIMER: To activate the timer from the remote
control, press the Timer Button ( ). From there
you can press the (+) or (-) button, which will
give you the ability to program the heater to turn
on or off in 1 hour increments, up to 16 hours.
For more information see Using Programmable
Timer instructions above.
AUTO SAFETY SHUT-OFF
This heater is equipped with a technologically
advanced, safety system that requires the user
to reset the heater if there is a potential overheat
situation. When a potential overheat temperature
is reached, the system will automatically shut
the heater off. It can only resume operation
when the user resets the unit.
To reset the heater
1. Press the MODE ( ) button.
2. Unplug the heater and wait for 30 minutes for
the unit to cool down.
3. After the 30 minutes, plug the unit in again
and operate normally.
Tip Over Protection
When the unit is accidentally knocked over, it will
instantly shut off. To reset, simply place the
heater in an upright position.
Safety Back-Up Fuse
In the unlikely case the heater does not respond
to an overheat situation, the safety back-up fuse
will engage. In this case, the heater will not
reset. Please contact your local service number
for advice.
PLEASE READ AND SAVE THESE
IMPORTANT INSTRUCTIONS
When using electrical appliances, basic safety
precautions should always be taken including
the following:
1. Before connecting the heater, check that the
voltage indicated on the rating plate
corresponds to the main voltage in your
home/office.
2. WARNING: In order to avoid overheating,
do not cover the heater ( ).
3. DO NOT position the heater directly under a
power socket.
4. Do not use this heater in the immediate
surroundings of a bath, a shower or a
swimming pool.
5. If the supply cord or plug is damaged, it must
be replaced by the manufacturer or its service
agent or similarly qualified person in order to
avoid hazard. The heater contains no user
serviceable parts. Should the product suffer
damage or breakdown, it must be returned to
the manufacturer or their service agent.
6. Under the environment with electrical fast
transient, the product may malfunction and
require user to reset the product.
DESCRIPTIONS:
A. Heater Housing
B. Neck
C. Pedestal Pole with 2 Halves
D. Base
E. Locking Nut
F. Power Cord
G. Remote Control Sensor
H. Power Light
I. Mode Button
J. Oscillation Button
K. Set Temperature/Timer Buttons
+ for Up
- for Down
L. Timer Button
ASSEMBLY INSTRUCTIONS
(SEE FIG. 1 AND 2)
If you are planning on using the pedestal, start
with Step 1
Step 1 – Turn the heater housing (A) upside
down and place on a firm, level surface
Step 2 – Unscrew the locking nut (E) by turning
counterclockwise. Slide the locking nut (E)
and base (D) to the end of the power cord.
Step 3 – Unclip the two halves of the pedestal
pole (C) and re clip the two halves (C)
around the power cord (F), insert the 2
fixing screws. (see Fig. 1)
Step 4 – Screw the pedestal pole (C) clockwise
onto the neck (B) threaded end on the
bottom of the heater housing (A) until
you feel resistance. (see Fig. 2)
Step 5 – Slide the base (D) and the locking nut
(E) up the cord, smooth surface facing
up. Make sure to align the dot on the
back of the base to the dot on the
pedestal pole (C) before tightening the
locking nut (E) (See Fig. 2).
Step 6 – Hold base (D) straight while tightening
the locking nut (E) by turning clockwise.
Step 7 – Insert the power cord into the notch at
the rear of the base.
Step 8 – Carefully turn the heater upright, place
on a firm, level surface.
OPERATING INSTRUCTIONS
Frost Guard
This special setting is automatically activated
when the (AF) mode is selected. In this mode,
the heater is off until the room's temperature
reaches freezing and the heater automatically
turns on HI power. The heater will cycle ON and
OFF as it maintains the temperature between 5-
8 °C.
Setting the Fan
Press the Mode Button ( ) once to operate
the fan only (FA).
Setting the Digital Thermostat:
Your heater is equipped with a Digital
Thermostat that allows you to set your heater to
your precise comfort level.
1. Press the Mode Button ( ) twice for manual
HI power. The heater will run continuously on
HI.
2. Press the Mode Button again for manual LO
power. The heater will run continuously on LO.
3. Press the Mode Button for a fourth time for Auto
Mode HI Power (AH) or press again for Auto
Mode LO Power (AL). In either of these modes
you may then press the up (+), and down (-)
buttons to set your desired temperature.
4. Once you have set your desired temperature,
the display will return to current room
temperature and gradually increase until the
room has reached the preset temperature.
5. If the unit will not start in the digital thermostat
mode, please make sure the “set temperature” is
higher than the current room temperature.
NOTE: It is normal for the heater to cycle ON
and OFF as it maintains the preset
temperature. To prevent the unit from cycling,
you need to raise the thermostat setting.
When the preset temperature is reached, the
fan will run for 30 seconds without heat. This
cool down process ensures an accurate and
consistent temperature reading.
6. Press the Mode Button one more time to turn
the heater to (AF) mode and one final time to
turn the heater off. When the heater is off, the
room temperature will only be displayed.
NOTE: The Mode Button can be pressed and
held for 3 seconds at any time to turn the heater
off.
NOTE: AccuTemp PlusTM has memory. The digital
thermostat will remember the previous temperature
setting after the unit has been turned off. However,
if the unit is unplugged, the digital thermostat will
be reset and will no longer remember the previous
temperature setting. If you unplug the heater, you
will have to reset the AccuTemp PlusTM again by
following the above instructions.
USING THE PROGRAMMABLE TIMER
AccuTemp PlusTM allows the user to program the
heater to turn on at a preset time, or turn off
after a set amount of time.
NOTE: At any time, the timer can be turned off
by selecting 0 hours.
U.K. and IRELAND
23
Especificaciones del producto
Marca: | Bionaire |
Categoría: | Calefacción |
Modelo: | BFH3520 |
¿Necesitas ayuda?
Si necesitas ayuda con Bionaire BFH3520 haz una pregunta a continuación y otros usuarios te responderán
Calefacción Bionaire Manuales
21 Agosto 2024
18 Agosto 2024
29 Julio 2024
25 Julio 2024
Calefacción Manuales
- Calefacción AEG
- Calefacción Remeha
- Calefacción Vaillant
- Calefacción Gude
- Calefacción Stiebel Eltron
- Calefacción Dimplex
- Calefacción Atlantic
- Calefacción Mill
- Calefacción Eberspacher
- Calefacción Blumfeldt
- Calefacción Day
- Calefacción Vasco
- Calefacción Jaga
- Calefacción REMKO
- Calefacción Thermor
- Calefacción Brink
- Calefacción Duronic
- Calefacción Kemper
- Calefacción Supra
- Calefacción Heatstrip
- Calefacción Myson
- Calefacción Webasto
Últimos Calefacción Manuales
18 Octubre 2024
5 Octubre 2024
5 Octubre 2024
7 Septiembre 2024
7 Septiembre 2024
5 Septiembre 2024
5 Septiembre 2024
3 Septiembre 2024
3 Septiembre 2024
3 Septiembre 2024