BlueDri AIR SHIELD 550 Manual de Usario

BlueDri No categorizado AIR SHIELD 550

Lee a continuación 📖 el manual en español para BlueDri AIR SHIELD 550 (2 páginas) en la categoría No categorizado. Esta guía fue útil para 2 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/2
Owners Manual
HEPA AIR SCRUBBER BD-AS550
Read and save these instructions.
550 South Ayon Ave
Azusa California 91702
844-240-0444
warranty@BlueDriUSA.com
BlueDriUSA.com
Owners Manual BlueDri® Air Shield 550 Hepa Air Scrubber |
Unit Assembly
Wear items exempt from warranty consideration include but may
not be limited to: power cords, transport wheels, castors, handle
grips, filters, screens, brushes and carbon brushes. Subject to the
conditions and exceptions stated in this warranty, BlueDri® warrants
the BlueDri® products to be free from defects in material and
workmanship, under normal use and service, for the periods listed under
the warranty policy to the original purchaser. At any time during the
warranty period, BlueDri® will furnish replacement parts for the
BlueDri® products to the original purchaser. Such parts will be
furnished and charged including transportation costs, to the original
owner. If the original part is returned within the warranty policy period
from date of delivery for inspection by BlueDri® and is found to be
defective, the owner will be credited for the cost of replacement parts
plus shipping and handling. Replacement parts that have become
defective through wear or abuse are not included in this warranty. This
warranty does not apply to damage or defect caused by accident, misuse,
negligence, fire or to any BlueDri® product which has been serviced or
repaired by other than an authorized BlueDri® Service Distributor or
BlueDri® factory personnel. This warranty is void if products are used
for any purpose other than that which was intended. There are no other
warranties expressed or implied. In no event shall BlueDri® be liable for
incidental or consequential damages or any damage to person or
property. (Please note some states do not allow the exclusion or
limitations for incidental and consequential damages.)
Warranty Policy
1-Year Coverage
Subject to the conditions stated below, BlueDri® offers a limited
warranty on parts and labor on the following equipment, parts and
accessories to be free from defects in material and workmanship
for a period of one year to the original purchaser.
5-Year Coverage
Subject to the conditions stated below, BlueDri® warrants parts
and labor on rotationally molded housings to be free from defects
in materials and workmanship for a period ofve years to the
original purchaser.
Part
Number Description Number Quantity
1 Motor AS-01 1
2 Motor Cover AS-02 1
3 Housing AS-03-C 1
4 Filter Cover AS-04 1
5 Exhaust Grill AS-05 1
6 Power Switch AS-06 1
7 GFCI SA-01 1
8 Circut Breaker AS-07 1
9 Hour Meter AS-08 1
10 Rubber Feet AS-09 8
11 Hepa Filter AS-10 1
12 Pre-Filter AS-11 1
Optional Carbon Filer AS-11-C 1
13 Intake Plug AS-12 1
AIR SHIELD 550
13
411 10
35
1
2
7
6
8
9
12
Owners Manual BlueDri® Air Shield 550 Hepa Air Scrubber |
The HEPA Air Scrubber is a portableltration system that removes
airborne particles including mold, pet dander, dust, pollen, drywall
dust, and other miscellaneous debris as small as 0.3 microns. The
AS-550 utilizes up to 3 stages of filtration including a pre-filter,
optional 2nd stage, and a HEPA filter. The AS-550 will create
cleaner air in any environment. The pre-filter and second stage
lter capture larger particles and the HEPA filter captures smaller
particles.
Warnings!
Do not move or carry the Air Scrubber while it is operating.
When the Air Scrubber is operating, the powerful airflow can
cause unpredictable movement.
NEVER allow children to play with or around the Air Scrubber.
Do not alter or modify your Air Scrubber in any way. Use only
replacement parts authorized by BlueDri®. Modifications or
use of unauthorized parts could create a hazard and will void
your warranty.
Store the Air Scrubber in a clean, dry environment. Do not
store outdoors or allow water inside the unit’s motor. If the
motor becomes wet, allow it to thoroughly dry before use.
The Air Scrubber should never be operated near water as it
will create a risk of serious injury from electrical shock.
Handle unit with care to avoid causing damage or injury.
The Air Scrubber should always be operated on aat surface.
Do not operate where unit could fall, or on slippery surfaces,
as this could increase the chance of injury,re, or electrical
shock.
Keep all liquids from being drawn into the Air Scrubber and
never operate unit without factory installed safety inlet and
outlet grills in place.
Do not use the Air Scrubber near combustible gas, or hot air as
unit could melt and cause a fire or electrical hazard.
Do not take the Air Scrubber apart or repair it unless you are
qualified to do so. Never repair or service unit while Air
Scrubber is plugged in.
Make sure the air intake and outlet are free from all materials
and away from obstructions, as any restrictions may cause the
Air Scrubber to overheat and cause a shock orre hazard.
Unplug the Air Scrubber before performing any service or
changinglters
Do not stack more than 2 units high in order to avoid a tipping
hazard – falling equipment can cause bodily harm.
Operation
1) Place the Air Scrubber upright on a level and stable surface
with the handle up.
2) Remove the dust cover.
3) Plug the Air Scrubber into a grounded 115 volt grounded
outlet with the correct voltage and amperage. For maximum
protection against electrical shock, ALWAYS use a circuit that is
protected by a ground fault circuit interrupter. If you are unsure
about the outlet, check with a qualified electrician or service
person. Do not use an adapter or extension cord.
4) To switch the unit on, locate the control panel and turn the
variable speed switch clockwise to the desired speed setting.
5) Operate unit until area is clear of unwanted contaminates or
until filters need to be changed. The control panel has alter
change light which illuminates when the HEPAlter needs to be
changed. See section on changing filters for instructions.
Auxiliary/GFCI Outlet/Daisy Chain
You can interconnect (“daisy-chain”) up to three AS-550’s to
customize your air filtration needs. The GFCI will “tripif it
detects a suddenground fault,or overload and interrupt the
electric current. When the GFCI “trips,unplug the unit and look
for potential hazards such as standing water, frayed cords, or
anything that would cause a dangerous electrical problem. If
such a situation exists, plug the AS-550 into a different outlet
and then push thereset” button which is located between the 2
outlets on the GFCI. If the unit will not operate check the circuit
breaker section below.
Unit Specifications
Certifications C-ETL-US
Motor Rating .33 hp
Power 115 Volts, 60 Hz
Current 2.5 amps
CFM 250-500
Pre Filter G4
Prime-Filter H13 (Made in Germany)
BlueDriUSA.com
Circuit Breaker Switch
The AS-550 is equipped with a circuit breaker switch to protect
the Air Scrubber. The switch is located directly above the GFCI
outlet and cuts off power to the unit when it detects an unsafe
amount of electricity passing through the unit. If the switch
“trips,unplug the unit and look for potential hazards or anything
that may be creating an overload situation. “Resetbreaker by
pushing button in and continue normal operation.
Changing Filters
Warning! Contaminated Hazard
Always wear NIOSH compliant protective gear when changing
lters and dispose of used lters according to your local
regulations.
Filters should be changed after every remediation job and whenever
the lter change indicator light comes on. The unit should also be
cleaned after each job to prevent cross-contamination.
Make sure the unit is dry before installing cleanlters.
To change filters:
1) Unplug the Air Scrubber
2) Open door by releasing sliding latches outward, away from the
air scrubber body.
3) Remove used filters and install new filters.
4) Latch door closed and plug the unit in a grounded outlet before
operating.
Warning!
For the safe operation of this machine follow the instructions
given in this booklet and the training provided. Failure to do
so can result in personal injury and/or damage to machine and
property!
DO NOT OPERATE MACHINE IN AN EXPLOSIVE ENVIRONMENT!
NOTE: In Canada, the use of a temporary adapter is not permit-
ted by the Canadian Electrical Code.
Problem
Air Scrubber does not turn on
Possible Cause/Solution
•Switch not turned on-turn
•Circuit breaker or GFCI has tripped-push rest button
•No power to scrubber-make sure unit is plugged in; check power supply
•Faulty switch-replace
Air Scrubber starts and then shuts off Obstructed inlet/outlet remove obstruction
•Faulty motor - replace
Air Scrubber vibrates •Motor shaft is bentreplace motor
•Fan blade is bentreplace
•Excessive dirt built up on fan blade clean by wiping with a slightly damp cloth.
Air Scrubber change light illuminated •HEPA filter needs replacement - replace
•Air intake restricted remove restriction or bends/kinks in ducting
Motor makes noises,
but Air Scrubber won’t turn on
•Damaged/faulty motor or motor shaft – replace
•Broken/loose wire to capacitor tighten
•Damaged/faulty capacitor – replace
•Damaged housing/fan so fan will not spin – replace housing or fan wheel
•Motor shaft set screw holding fan wheel is loose - tighten
Read all warnings and instructions before using this unit. Read all warnings and instructions before using this unit.
Specifications are subject to change without notice.
USE 115V
3-PRONG
GROUNDED
CONNECTION
DO NOT USE
ADAPTER

Especificaciones del producto

Marca: BlueDri
Categoría: No categorizado
Modelo: AIR SHIELD 550

¿Necesitas ayuda?

Si necesitas ayuda con BlueDri AIR SHIELD 550 haz una pregunta a continuación y otros usuarios te responderán




No categorizado BlueDri Manuales

No categorizado Manuales

Últimos No categorizado Manuales