Bogen NQ-GA40P3 Manual de Usario

Bogen receptor NQ-GA40P3

Lee a continuación 📖 el manual en español para Bogen NQ-GA40P3 (4 páginas) en la categoría receptor. Esta guía fue útil para 4 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/4
Specications are subject to change.
© Copyright 2022, Bogen Communications LLC
740-00158E 230727
NQ-GA40P3 Integrated Power Amplier
Installation and Use Guide
The NQ-GA40P3 is a 40W plenum-rated Class D integrated power amplier.
Designed to operate over a 10/100 Ethernet network, the NQ-GA40P3 is
IEEE 802.3bt–compliant and can be powered using Power over Ethernet
(PoE++). The NQ-GA40P3 can direct drive a single 8Ω load and has a bal-
anced line output to drive auxiliary power ampliers, as well as a balanced
line input for auxiliary line-level analog input.
Notice
Every effort was made to ensure that the information in this manual was
complete and accurate at the time of printing; however, all information is
subject to change.
This equipment is not suitable for use in locations where children are likely to be present.
Equipment is intended for use only in a restricted access area.
WARNING: To reduce the risk of re or electric shock, do not expose this apparatus to rain or moisture.
Avertissement: pour réduire le risque d’incendie ou de choc électrique, ne pas exposer cet appareil sous la pluie et
l’humidité.
The apparatus shall not be exposed to dripping or splashing and no objects lled with liquids, such as vases, shall
be placed on apparatus.
Lappareil ne doit pas être exposé aux écoulements ou aux éclaboussures et aucun objet ne contenant de liquide, tel
qu’un vase, ne doit être plasur l’objet.
The ventilation should not be impeded by covering the ventilation openings with items, such as newspapers, ta-
ble-cloths, curtains, etc.
- il convient que l’aération ne soit pase par lobstruction des ouvertures d’ra
No naked ame sources, such as lighted candles, should be placed on the apparatus.
- il convient de ne pas placer sur lappareil de sources de ammes nues, telles que des bougies allumées
The apparatus should be used in moderate climates.
- si l’appareil est desti à être utilisé sous un climat tempéré.
2
NQ-GA40P3
Important Safety Information
WARNING: To reduce the risk of re or electric shock, do not expose this apparatus to rain or moisture.
Always comply with the following basic safety precautions when installing and using the unit:
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Clean only with dry cloth.
6. DO NOT install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including
ampliers) that produce heat.
7. Only use attachments/accessories that are specied by the manufacturer.
8. Unplug this apparatus during lightning storms or when unused for long periods of time.
9. Refer all servicing to qualied service personnel. Servicing is required when the apparatus has been damaged in
any way, such as: the power-supply cord or plug is damaged, liquid has been spilled onto (or objects have fallen
into) the apparatus, the apparatus has been exposed to rain or moisture, or the apparatus does not operate
normally or has been dropped.
10. Maximum operating temperature is 35 °C.
11. The wall mounting height of the NQ-GA40P3 should be equal to or less than two meters. The mounting process
should be conducted by trained professionals with sucient knowledge and tools to reliably t the wall-mount
fasteners.
Installation
To install the NQ-GA40P3 amplier:
1. Attach the desired analog speaker to
the NQ-GA40P3 using the pluggable
connectors provided, where the + and
− terminals connect to the +/− speaker
wires (see “Figure 1” on page 2).
2. If desired, attach an auxiliary amplier
to the NQ-GA40P3 using pins 1 and 2
of the pluggable balanced LINE OUT
connector, taking note of the marked
polarity (+/−). The G shield terminal
can be used if necessary.
3. If desired, line level output from a
preamplier device can be connected
to the NQ-GA40P3 using pins 1 and 2
of the pluggable balanced line connec-
tor, taking note of the marked polarity
(+/−). The G shield terminal can be
used, if necessary.
4. Connect a Cat5-type cable into the
modules Ethernet port and ensure the
other end of the cable is correctly connected to a PoE switch port on your network.
To balanced input
of auxiliary amplifier.
Use shielded cable.
+
8Ω (ohms)
40W (PoE++)
20W (PoE+)
10W (PoE)
Aux Preamplifier
From output of auxiliary
preamplifier. Use shielded
cable.
+G
+
AMP LINE
OUT
− −+G
Aux Amplifier
LINE
IN
Speaker
Figure 1
3
NQ-GA40P3
Viewing and Understanding LEDs
Two LEDs appear on the front of the . One is labeled POWER and appears amplier chassis
as solid red during initial power up, ashes green during a boot sequence, and appears solid
green when fully booted.
The STATUS LED uses the following indicators to provide information about the module:
Flashing red: No network connection found.
Solid blue: The amplier is in an uninitialized state and is not associated to a server. (The server may be in a
discovery mode.)
Solid green: The amplier is registered to a Nyquist server and is in normal operation.
Flashing green: The amplier has an IP address but is not registered with the Nyquist server.
Solid red: The amplier needs to be rebooted or reset so that the Nyquist application can resume.
Flashing blue: The amplier is updating.
Using the Reset Button
The Reset button allows you to restart the amplier or to reset the amplier’s conguration settings
to the factory default settings.
For more information about resetting conguration settings, refer to the Nyquist NQ-GA40P3 Cong-
uration Guide.
Temperature Indicator
In addition to the LEDs that appear on the actual appliance, a separate temperature status indicator appears on the
modules web-based user interface. For more information, refer to the Nyquist NQ-GA40P3 Conguration Guide.
Accessories
The PI5660W PoE++ injector can be purchased from Bogen in lieu of using a PoE++–compatible network switch.
Visit www.bogen.com for more information.
Compliance
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.