7213 8200 - 02/2006 GB (EN) for the user
Users manual
ModuLink 250 RF - Single channel modulating
programmable room thermostat
Please read thoroughly before operating the unit
See boiler installation instructions for more details
CH
10:41
am
auto
20
˚C
5
24 Volt only
Users manual
2 Buderus
Overview (fig. 1)
Item 1. Central Heating button
With this button you select whether you want the
thermostat on, off or on auto.
on: The boiler is now continuously 'on'.
Set the temperature with the and
keys.
auto: The boiler will now operate according to
the set CH program.
off: Continuously off, but the frost protection
programme is active. This means that
when the temperature drops below 5°
Celsius the boiler will be activated.
Item 2. Display
The display shows the current setting of the ther-
mostat (fig. 2, item 5), the current temperature
during standby (fig. 2, item 1), and the current
time (fig. 2, item 2).
Item 3. and buttons
Use these buttons to adjust the temperature.
This is permanent when the thermostat is set to
'on'. When the thermostat is set to 'auto', you
can temporarily change the temperature of a
setpoint. The thermostat reverts back to its
CH program when the next set point begins.
The buttons can also be used to navigate within
the menu.
Item 4. OK button
This button is pressed to confirm/save settings.
Item 5. Cover
To open the cover, pull on the side.
Item 6. Batteries
The thermostat runs on two 1.5V type AA Alka-
line batteries. The batteries will last for at least
one year. A symbol of a battery (fig. 2, item 4)
will appear if the batteries should be replaced.
Once the battery replacement is carried out, you
need to reset the time. All other settings are
kept.
Item 7. Menu button
Press this button to enter and exit the menu.
Item 8. Back button
This button allows you to go back one menu
level.
fig. 1 Thermostat overview
CH
10:41
am
auto
20
˚C
5
mok
1
2
3
8
7
4
5
6
fig. 2 Display
on
auto
off 20 0
˚C
am 09 23
:
5
1
2
43
Users manual
Buderus 3
Setting the time
Press . Press and use the and
keys to set the hours. The range is from 0-24
hours or 1-12 a.m. and 1-11 p.m.. Once you
scrolled through the 24h format using the up
key, it changes to the 12h format.
Press again. Use the and keys to
set the minutes and press to confirm.
Press to return to the regular display.
View/edit set point(s)
There are six set points possible. These set
points are for a 24 hour period and are repeated
each day of the week. Factory setting:
6:30 – 21.0° Celsius
8:30 – 15.0° Celsius
12:30 – 21.0° Celsius
14:00 – 15.0° Celsius
16:30 – 21.0° Celsius
22:30 – 15.0° Celsius.
1. Press to enter the menu.
2. Press to go to the 2nd menu item
'CH prog' then press .
3. Press again to view/edit the set points.
Use the and keys to scroll through
the set points.
4. Press when you want to edit a set point.
5. Use the and keys to adjust the time
and confirm with .
6. Adjust the temperature using the and
keys and confirm with .
7. Press to return to the regular display.
Current set point
To see what the current set point is press the
CH button once.
Insert a set point
1. Press to enter the menu.
2. Press to go to the 2nd. menu item
'CH prog' then press .
3. Press to go to 'insert' then press .
4. Use the and keys to enter the time
and press .
5. Use the and keys to enter the desired
temperature and press .
6. Press to insert another set point as
starting from step 4 or press to return to
the regular display.
The set point will automatically arrange itself to
the correct position within the CH program.
Delete a set point
1. Press to enter the menu.
2. Press to go to the 2nd menu item
'CH prog' then press .
3. Press to go to 'delete' then press .
4. Select the set point you want to delete using
the and keys then press .
5. Press to delete another set point
starting from step 4 or press to return to
the regular display.
Holiday function
The holiday function allows you to set the tem-
perature to frost protection (5° Celsius) for up to
99 days. Afterwards the thermostat automati-
cally reverts back to the CH program.
1. Press to enter the menu.
2. Press to go to 'Holiday' then press .
3. Enter the number of days using the and
keys then press .
4. Press to return to regular display.
A suitcase can be seen in the display when the
Holiday function is active (see fig. 2, item 3).
To terminate the holiday function set the number
of days to '0'.
It is possible to temporarily interrupt the Holiday
function. Set the thermostat to 'on' using the
button. Set the thermostat back to 'auto'
using the button to return to the Holiday
function.
Especificaciones del producto
Marca: | Buderus |
Categoría: | Termostato |
Modelo: | ModuLink 250 RF |
¿Necesitas ayuda?
Si necesitas ayuda con Buderus ModuLink 250 RF haz una pregunta a continuación y otros usuarios te responderán
Termostato Buderus Manuales
16 Septiembre 2024
16 Septiembre 2024
12 Agosto 2024
3 Agosto 2024
Termostato Manuales
- Termostato ATAG
- Termostato Bosch
- Termostato AEG
- Termostato Panasonic
- Termostato Honeywell
- Termostato Junkers
- Termostato Nefit
- Termostato Remeha
- Termostato Siemens
- Termostato Vaillant
- Termostato Ambiano
- Termostato Amfra
- Termostato Google
- Termostato Renkforce
- Termostato Itho
- Termostato De Dietrich
- Termostato Elro
- Termostato EMOS
- Termostato Truma
- Termostato Intergas
- Termostato Schneider
- Termostato Hama
- Termostato Fenix
- Termostato Theben
- Termostato Elektrobock
- Termostato Devi
- Termostato Stiebel Eltron
- Termostato Dimplex
- Termostato Vemer
- Termostato Profile
- Termostato Magnum
- Termostato Horstmann
- Termostato Salus
- Termostato Tylö
- Termostato Somfy
- Termostato Grohe
- Termostato Corberó
- Termostato Oventrop
- Termostato King
- Termostato Technoline
- Termostato Devolo
- Termostato Arnold Rak
- Termostato Heatmiser
- Termostato Viessmann
- Termostato Carrier
- Termostato Nest
- Termostato Itho-Daalderop
- Termostato Hive
- Termostato Danfoss
- Termostato Saunier Duval
- Termostato Netatmo
- Termostato Seitron
- Termostato Sygonix
- Termostato Tado
- Termostato Hunter
- Termostato Busch-Jaeger
- Termostato Bulex
- Termostato AWB
- Termostato Finder
- Termostato Xavax
- Termostato Fantini Cosmi
- Termostato Delta Dore
- Termostato Orbis
- Termostato EBERLE
- Termostato Grasslin
- Termostato Gira
- Termostato Jung
- Termostato Wolf
- Termostato HQ
- Termostato Max
- Termostato Frico
- Termostato Vasco
- Termostato Radson
- Termostato Nobo
- Termostato Baxi
- Termostato EQ3
- Termostato Homematic IP
- Termostato Weishaupt
- Termostato REMKO
- Termostato ICY
- Termostato Computherm
- Termostato Avidsen
- Termostato Crestron
- Termostato ORNO
- Termostato Berker
- Termostato Drayton
- Termostato Heatit
- Termostato Watts
- Termostato Etherma
- Termostato Eurotronic
- Termostato Oregon Scientific
- Termostato Muller
- Termostato Econo-Heat
- Termostato PECO
- Termostato H-Tronic
- Termostato Intertechno
- Termostato EQ-3
- Termostato Tru Components
- Termostato Emko
- Termostato Easy Timer
- Termostato IMIT
- Termostato Maico
- Termostato HomePilot
- Termostato THERMAFLEX
- Termostato Wachendorff
- Termostato Plugwise
- Termostato Johnson Control
- Termostato Drayton Erie
- Termostato Lowes
- Termostato Jumo
- Termostato Warmup
- Termostato Qubino
- Termostato STI
- Termostato ELKO
- Termostato TrickleStar
- Termostato Gewiss
- Termostato Sinustec
- Termostato Rose LM
- Termostato Otio
- Termostato MundoControl
- Termostato Enda
- Termostato Bearware
- Termostato GENERAL Life
- Termostato Oreg
Últimos Termostato Manuales
27 Octubre 2024
27 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024