Cactus 270P Manual de Usario

Lee a continuación 📖 el manual en español para Cactus 270P (30 páginas) en la categoría Destello de luz. Esta guía fue útil para 5 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/30
1
Cactus Technologies, Limited
Commercial Grade
-270P series
CFexpress Card
Product Manual
October 20, 2021
www.cactus-tech.com
Cactus Technologies, Limited
The information in this manual is preliminary and is subject to change without notice. Cactus Technologies ® , Limited shall not
be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages resulting
from the furnishing, performance, or use of this material.
Cactus Technologies® makes no warranty, representation or guarantee regarding the suitability of its products for any particular
purpose, nor does Cactus Technologies® assume any liability arising out of the application or use of its products, and specifically
disclaims any and all liability, including without limitation consequential or incidental damages.
Cactus Technologies® products are not designed, intended or authorized for use as components in systems intended for surgical
implant into the body or in other applications intended to support or sustain life or for any application where the failure of a
Cactus Technologies® product can result in personal injury or death. Users of Cactus Technologies® products for such
unintended and unauthorized applications shall assume all risk of such use and shall indemnify and hold Cactus
Technologies® and its officers, employees, subsidiaries, affiliates and distributors harmless against all claims, costs, damages,
expenses and attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such
unintended and unauthorized use, even if such claim alleges that Cactus Technologies® was negligent regarding the design or
manufacture of the part.
All parts of the Cactus Technologies® documentation are protected by copyright law and all rights are reserved. This
documentation may not, in whole or in part, be copied, photocopied, reproduced, translated, or reduced to any electronic
medium or machine-readable form without prior consent, in writing, from Cactus Technologies®, Limited.
© 2005-2021 Cactus Technologies® Limited. All rights reserved.
Cactus Technologies Limited Industrial Grade -270P Series CFexpress Card Product Manual v1.0 2
Cactus Technologies, Limited
Table of Contents
1. Introduction to Cactus Technologies® Commercial Grade -270P Series CFexpress Card Products..........................5
1.1. Supported Standards..................................................................................................................................6
1.2. Product Features........................................................................................................................................6
1.2.1. Host and Technology Independence...............................................................................................6
1.2.2. Defect and Error Management........................................................................................................6
1.2.3. Power Supply Requirements...........................................................................................................7
2. Product Specifications.................................................................................................................................................7
2.1. System Environmental Specifications.......................................................................................................7
2.2. System Power Requirements.....................................................................................................................7
2.3. System Performance..................................................................................................................................8
2.4. System Reliability......................................................................................................................................8
2.5. Physical Specifications..............................................................................................................................9
3. Interface Description...................................................................................................................................................9
3.1. CFexpress Card Pin Assignments and Pin Type.....................................................................................10
4. Electrical Specifications............................................................................................................................................10
4.1.1. Absolute Maximum Ratings..........................................................................................................11
4.1.2. DC Characteristics.........................................................................................................................11
4.1.3. AC Characteristics.........................................................................................................................11
5. PCI Configuration.....................................................................................................................................................11
5.1. PCI Express Capabilities.........................................................................................................................12
5.2. NVM Express Registers..........................................................................................................................14
5.2.1. Controller Capabilities (CAP).......................................................................................................14
5.2.2. Version (VS)..................................................................................................................................15
5.2.3. Interrupt Mask Set (INTMS).........................................................................................................15
5.2.4. Interrupt Mask Clear (INTMC).....................................................................................................15
5.2.5. Controller Configuration (CC)......................................................................................................16
5.2.6. Controller Status (CSTS)...............................................................................................................16
5.2.7. NVM Subsystem Reset (NSSR)....................................................................................................17
5.2.8. Admin Queue Attributes (AQA)...................................................................................................17
5.2.9. Admin Submission Queue Base Address (ASQ)..........................................................................17
5.2.10. Admin Completion Queue Base Address (ACQ)........................................................................17
5.2.11. Controller Buffer Memory Location (CMBLOC).......................................................................17
5.2.12. Controller Buffer Memory Size (CMBSZ).................................................................................18
5.2.13. Boot Partition Info (BPINFO).....................................................................................................18
5.2.14. Boot Partition Read Select (BPRSEL)........................................................................................18
5.2.15. Boot Partition Memory Buffer Location (BPMBL)....................................................................18
5.2.16. Submission Queue y Tail Doorbell (SQyTDBL)........................................................................18
5.2.17. Completion Queue y Head Doorbell (CQyHDBL).....................................................................19
6. Identify Command....................................................................................................................................................19
6.1. Identify Controller Data Struture.............................................................................................................19
7. SMART Reporting....................................................................................................................................................23
7.1. SMART Attributes...................................................................................................................................23
Cactus Technologies Limited Commercial Grade -270P Series CFexpress Card Product Manual v1.0 3

Especificaciones del producto

Marca: Cactus
Categoría: Destello de luz
Modelo: 270P

¿Necesitas ayuda?

Si necesitas ayuda con Cactus 270P haz una pregunta a continuación y otros usuarios te responderán