Cadac Meridian Built-in Manual de Usario

Cadac No categorizado Meridian Built-in

Lee a continuación 📖 el manual en español para Cadac Meridian Built-in (43 páginas) en la categoría No categorizado. Esta guía fue útil para 6 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/43
MODEL No: 982231 & 982241
(28mBar)
MERIDIAN 3 & 4 BUILT-IN
MERIDIAN 3
982231
MERIDIAN 4
982241
503-0479 LEV6
USER INSTRUCTIONS
LIVE THE BRAAI LIFE
NOTE! PRODUCT MAY VARY FROM ILLUSTRATIONS
GB DE DK ES FR IT NL NO PL SE SI
11
CAUTION
Provide ample ventilation. This gas appliance consumes air (oxygen). Do not use this appliance in an unventilated space to
avoid endangering your life. If still more gas appliances and/or occupants using gas are added to the space, additional ventilation
must be provided.
IMPORTANT
Read these instructions carefully so as to familiarise yourself with the appliance before ting the appliance to a gas cylinder.
Retain these instructions for future reference.
GB
1. General
This appliance complies with BS EN498:2012 and SANS 1539:2017.
This appliance may only be used with an approved hose and regulator (A 2.8kPa hose and regulator supplied with this unit in South
Africa)
The gas cylinder is to be used in the upright position.
Only to be used with a gas cylinder that does not exceed 500mm in height(Regulator is included) and 400 mm in width.
Gas appliances require ventilation for efcient performance and to ensure the safety of users and other persons in close proximity.
Accessible parts may be very hot. Keep young children away.Warning:
After use, turn off the gas supply at the cylinder, and then at the control knobs.
Use outdoors only!
Gas Supply Sources An approved hose and regulator connected to a rellable gas container not exceeding 9kg and
complying with local regulation in force
Country of Use
BE, CH, CY, CZ, ES, FR, GB,
GR, IE, IT, LT, LU, LV, PT,
SK & SI
PL
BE, CY, DK, EE, FR, FI, HU,
IT, LT, NL, NO, SE, SI, SK, RO,
HR, TR, BG, IS,LU, MT & ZA,
Appliance Catagories I3B/P (30) I3+(28-30/37) I3B/P (37)
Allowable gasses
Butane @ 28-30mBar
Propane @ 28-30mBar
Butane/Propane mixtures
@ 28-30mBar
(South Africa 2.8kPa)
Butane @ 28-30mBar
Propane @ 37mBar
Butane @ 37mBar
Propane @ 37mBar
Butane/Propane mixtures
@ 37mBar
Main 3 Burner BBQ Unit
Jet Number 0.92
Nominal Usage Butane - 233 g/h
per burner
Butane - 233 g/h
per burner
Butane - 276 g/h
per burner
Gross nom. heat input 3.2 kW per burner
(3.2 kW x 3 = 9.6 kW in total)
3.2 kW per burner
(3.2 kW x 3 = 9.6 kW in total)
3.8 kW per burner
(3.8 kW x 3 = 11.4 kW in total)
Main 4 Burner BBQ Unit
Jet Number 0.92
Nominal Usage Butane - 226 g/h
per burner
Butane - 226 g/h
per burner
Butane - 276 g/h
per burner
Gross nom. heat input
3.1 kW per burne
(3.1 kW x 4 = 12.4 kW in
total)
3.1 kW per burner
(3.1 kW x 4 = 12.4 kW in
total)
3.8 kW per burner
(3.8 kW x 4 = 15.2 kW in total)
Country Name and Abbreviations
AE = United Arab Emirates AL = Albania AT = Austria BE = Belgium CH = Switzerland
CZ = Czech Republic DE = Germany DK = Denmark ES = Spain FI = Finland
FR = France GB = United Kingdom GR = Greece HR = Croatia IT = Italy
JP = Japan KR = Korea NL = Netherlands NO = Norway PL = Poland
PT = Portugal RO = Romania RU = Russia RS = Serbia SI = Slovenia
SK = Slovakia SE = Sweden TR = Turkey ZA = South Africa
For gas category I3B/P(30) & I3+(28-30/37)
Meridian 3 Built-in, 982231, total heat input: 9.6kW/Butane 699g/h
Meridian 4 Built-in, 982241, total heat input: 12.4kW/Butane 902g/h
For gas category I3B/P(37)
Meridian 3 Built-in, 982231, total heat input: 11.4kW/Butane 830g/h
Meridian 4 Built-in, 982241, total heat input: 15.2kW/Butane 1106g/h