Clamp multimeter
EN - User’s manual
F604
3
0
0
0
A
2
0
0
0
A
1
0
0
0
V
C
A
T
I
V
1
5
0
0
V
C
A
T
I
I
I
COM +
1000 V CAT IV
1500 V CAT III
1700 V
1200 V
max
F604
AC/DC TRMS CLAMP METER
OFF
A
V
Adp
T °
°F
°C
P
AC DC
M MAX IN
kHz
kVA
%
0
°C°F
REL Ref
k
HOLD
2
WARNING, risk of DANGER ! The operator should refer to this user's manual whenever this danger symbol appears.
Application or withdrawal authorized on bare conductors carrying dangerous voltages. Type A current sensor as per
IEC/EN 61010-2-032 or BS EN 61010-2-032.
Battery.
Equipment protected throughout by double or reinforced insulation.
Earth.
The CE marking indicates compliance with the European Low Voltage Directive (2014/35/EU), Electromagnetic
Compatibility Directive (2014/30/EU), and Restriction of Hazardous Substances Directive (RoHS, 2011/65/EU and
2015/863/EU).
The UKCA marking certies that the product is compliant with the requirements that apply in the United Kingdom,
in particular as regards Low-Voltage Safety, Electromagnetic Compatibility, and the Restriction of Hazardous
Substances.
AC - Alternating current.
AC and DC - Alternating and direct current.
The rubbish bin with a line through it indicates that, in the European Union, the product must undergo selective
disposal in compliance with Directive WEEE 2012/19/EU. This equipment must not be treated as household waste.
Denitions of the measurement categories
Measurement category IV corresponds to measurements taken at the source of low-voltage installations.
Example: power feeders, meters and protection devices.
Measurement category III corresponds to measurements on building installations.
Example: distribution panel, circuit-breakers, machines or xed industrial devices.
Measurement category II corresponds to measurements taken on circuits directly connected to low-voltage installations.
Example: power supply to domestic electrical appliances and portable tools.
You have just acquired an and we thank you.F604 clamp multimeter
For best results from your device:
read this user manual attentively,
observe the precautions for its use.
3
CONTENTS
1. DELIVERY CONDITION ......................................................................................................................................................4
2. PRESENTATION ..................................................................................................................................................................5
2.1. The switch ...................................................................................................................................................................6
2.2. The keys of the keypad 7 ...............................................................................................................................................
2.3. The display unit 8 ...........................................................................................................................................................
2.4. The terminals ...............................................................................................................................................................9
3. THE KEYS ...........................................................................................................................................................................10
3.1. HOLD key 10 ................................................................................................................................................................
3.2. key (second function) .................................................................................................................................... 11
3.3. key ................................................................................................................................................................. 11
3.4. MAX/MIN key ................................................................................................................................................................. 11
3.5. Hz key 12 .................................................................................................................................................................
3.6. key 13 .................................................................................................................................................................
4. USE ...................................................................................................................................................................................... 14
4.1. Commissioning 14 ..........................................................................................................................................................
4.2. Starting up the clamp multimeter 14 ...............................................................................................................................
4.3. Switching the clamp multimeter 14 .................................................................................................................................
4.4. Conguration .............................................................................................................................................................14
4.5. Voltage measurement (V) 16 ..........................................................................................................................................
4.6. Continuity test .................................................................................................................................................16
4.7. Resistance measurement ......................................................................................................................................17
4.8. Diode test ........................................................................................................................................................17
4.9. Current measurement (A) 17 ..........................................................................................................................................
4.10. Starting current or over-current (True INRUSH) measurement 19 ...............................................................................
4.11. Frequency measurement (Hz) 19 .................................................................................................................................
4.12. Temperature measurement .....................................................................................................................................20
4.13. Adapter function measurement 21 ................................................................................................................................
5. CHARACTERISTICS .........................................................................................................................................................22
5.1. Reference conditions 22 .................................................................................................................................................
5.2. Characteristics under the reference conditions 22 .........................................................................................................
5.3. Environmental conditions 25 ..........................................................................................................................................
5.4. Characteristics of construction 25 ..................................................................................................................................
5.5. Power supply 26 .............................................................................................................................................................
5.6. Compliance with international standards 26 ...................................................................................................................
5.7. Variations in the domain of use 27 .................................................................................................................................
6. MAINTENANCE ..................................................................................................................................................................28
6.1. Cleaning 28 ....................................................................................................................................................................
6.2. Replacement of the batteries 28 .....................................................................................................................................
7. WARRANTY ........................................................................................................................................................................28

Especificaciones del producto

Marca: Chauvin Arnoux
Categoría: multimetro
Modelo: F604

¿Necesitas ayuda?

Si necesitas ayuda con Chauvin Arnoux F604 haz una pregunta a continuación y otros usuarios te responderán




multimetro Chauvin Arnoux Manuales

multimetro Manuales

Últimos multimetro Manuales