CRU DE50 Manual de Usario
Lee a continuación 📖 el manual en español para CRU DE50 (2 páginas) en la categoría Cradle/docking station. Esta guía fue útil para 2 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/2
Rugged, Reliable, Mobile, SecureTM
1-800-260-9800 www.CRU-DataPort.com
DE50 IDE Install Guide
Removable Ultra ATA 100 Drive Enclosure
NOTE: For Ultra ATA100 (100MByte/sec) operation, an Ultra ATA100 control-
ler and hard drive(s), and appropriate 40-pin, 80-conductor cable are required.
Drive Carrier Installation
1. Loosen and remove the four (4) M3 Phillips Flat Hd. screws located on
the sides of the drive carrier unit. Save these screws for Step 6.
2. Since the drive carrier unit is shipped pre-assembled, disassemble the
drive carrier unit into its three (3) main components (Figure 1).
3. Install the Drive Carrier Circuit Board (cable-side down) onto the drive
by attaching the I/O cable on the board to the drive.
4. Set Master/Slave drive designation. There are two ways to set the
Master/Slave drive designation for the DE50 unit, as described below.
NOTE: The information below is based on typical drive specifications.
Since specifications (specifically, pin assignments) between drive
manufacturers may vary, please refer to your drive manufacturer’s
documentation for information regarding Master/Slave configuration.
Cable Select Method (Recommended Method)
In most cases, there is no need to reconfigure the jumper on JMP1 located
on the rear of the drive carrier circuit board. A factory-installed jumper on
Pins B & D forces the drive into a Cable Select configuration (Figure 2).
With Cable Selection, the Master/Slave Drive designation is handled by
the Master/Slave Selection Jumper Option (J2) on the receiving frame
motherboard. If necessary, reconfigure jumper (factory-configured jumper
is for Master Drive designation). Skip section “Drive Select Method” and
continue with Step 5 of the Installation process.
Top
Cover
Drive Mounting
Bracket/Bottom
Plate Assembly
Drive Carrier
Circuit Board
Drive Select Method
In most cases, this method forces the drive into either a Master or Slave
Drive configuration. This method will override any configuration of the Mas-
ter/Slave Selection Jumper Option (J2) on the receiving frame motherboard.
The J2 jumper option is instead used to configure the unit ID display.
Master Drive
Remove the jumper from JMP1. Typically, no jumper installed on JMP1
forces the carrier into a Master Drive configuration (Figure 2).
Leave the J2 jumper option (on the receiving frame motherboard) as is for
Master Drive ID display purposes (factory-configured jumper is for Master
Drive designation).
Slave Drive
Install the jumper on JMP1 Pins C & D (Figure 2). Typically, a jumper
installed on Pins C & D forces the drive into a Slave Drive configuration
(refer to the drive manufacturer’s documentation for exact master/slave
jumper settings and reconfigure the jumper as necessary).
Configure the J2 jumper option for Slave Drive ID display purposes.
5. Carefully turn the drive/circuit board assembly upside-down (drive is
bottom-mounted into bracket). Install the drive mounting bracket and
secure with four (4) M3 screws (provided).
NOTE: Make sure that the drive circuit board is properly seated in
the mounting bracket slot before tightening screws.
6. Carefully insert the drive/bracket assembly into the top cover and
secure with the four (4) M3 screws (saved from Step 1).
Figure 1: Drive Carrier Disassembly
Figure 2: Drive Carrier Circuit Board
I/O Connector
Recommended
Configuration
or
Typical Master Drive
Configuration
No Jumper
Installed
Typical Slave Drive
Configuration
Jumper Installed
on Pins C & D
Cable Select
Configuration
Jumper Installed
on Pins B & D
(Factory Default)
Rugged, Reliable, Mobile, SecureTM
1-800-260-9800 www.CRU-DataPort.com
Master/Slave J2 Jumper Option on the Receiving Frame Mother-
board (Figure 3)
Master/Slave Selection Jumper (J2)
Master Drive configuration (Factory Default). Change jumper position to set
Slave Drive configuration.
Forces master/slave drive configuration on the receiving frame if JMP1
jumper option (located on the drive carrier circuit board) is configured to
Cable Select.
If using the Drive Select Method, this option is instead used to configure
the unit ID display (refer to Figure 4 for further information).
For 5.25” peripheral slots, the 5.25” adapter bracket must be installed. The
receiving frame is side-mounted into the adapter bracket using four (4) M3
Phillips Pan Head screws (provided).
With the drive carrier locked in place inside the receiving frame, install the
DE50 into the 5.25” drive opening in the computer or expansion chassis.
Use the appropriate guides to position the DE50 unit, and fasten it into
place with four (4) self-tapping screws (included). Mounting holes are pro-
vided on each side and the bottom of the adapter bracket to accommodate
a variety of mounting configurations. Use the mounting holes which best
suit the computer or expansion chassis configuration.
Unit ID Select Switches Settings
The following table lists the unit ID select switch settings and the valid AT/
IDE unit numbers. Please note that all invalid switch settings have shaded
boxes and result in a blank display in the receiving frame window.
NOTE: The unit ID number display is for ID display purposes only (when
using the Drive Select Method). The master/slave setting must still be set
on the DE50 unit itself (refer to Page 1 for further information).
Selecting the Unit ID Number
Use the alignment tool (provided) to select the ID number of the disk drive.
NOTE: The lock on the Data Express receiving frame functions as a
lock and a DC power switch for the carrier unit. The lock MUST be
engaged (turned counterclockwise) in order to supply power to the
carrier and installed drive unit.
Limited Product Warranty
CRU-DataPort (CRU) warrants the Data Express DE50 to be free of signifi-
cant defects in material and workmanship for a period of three years from
the original date of purchase. CRU’s warranty is nontransferable and is
limited to the original purchaser.
Limitation of Liability
The warranties set forth in this agreement replace all other warranties. CRU
expressly disclaims all other warranties, including but not limited to, the
implied warranties of merchantability and fitness for a particular purpose
and non-infringement of third-party rights with respect to the documen-
tation and hardware. No CRU dealer, agent or employee is authorized to
make any modification, extension, or addition to this warranty. In no event
will CRU or its suppliers be liable for any costs of procurement of substi-
tute products or services, lost profits, loss of information or data, computer
malfunction, or any other special, indirect, consequential, or incidental dam-
ages arising in any way out of the sale of, use of, or inability to use any CRU
product or service, even if CRU has been advised of the possibility of such
damages. In no case shall CRU’s liability exceed the actual money paid for
the products at issue. CRU reserves the right to make modifications and
additions to this product without notice or taking on additional liability.
Certification
EMI Standard: FCC Part 15 Class B, CE
EMC Standard: EN55022, EN55024
FCC Certification
This device has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received; including interfer-
ence that may cause undesired operation.
Register your product at www.CRU-DataPort.com
A7-050-0001 Rev 2.1
Figure 3: Receiving Frame
Motherboard (rear view)
Figure 5: Unit ID Select Switch Location
I/O
Connector
Master Drive Select (0)
(Factory Default)
Slave Drive
Select (1)
5.25” Adapter Bracket
(shown installed)
Key Lock &
Power Switch
Eject Button
Unit ID Select
Switch Location Unit ID Number
Indicator
Figure 4: Unit ID Select Switch Settings
J2 DC Power
Connector
= Pin1
Activity Indicator
Unit ID Select
Position 0 1 2 3 4 5 6 7 8 9
Unit ID Select
Position XMas-
ter Slave X X Mas-
ter Slave XXX
Unit ID Number
Display Blank 0 1 Blank Blank 2 4 Blank Blank Blank
Especificaciones del producto
Marca: | CRU |
Categoría: | Cradle/docking station |
Modelo: | DE50 |
¿Necesitas ayuda?
Si necesitas ayuda con CRU DE50 haz una pregunta a continuación y otros usuarios te responderán
Cradle/docking station CRU Manuales
9 Septiembre 2024
Cradle/docking station Manuales
- Cradle/docking station Philips
- Cradle/docking station JBL
- Cradle/docking station Pioneer
- Cradle/docking station Akai
- Cradle/docking station Altec Lansing
- Cradle/docking station ACME
- Cradle/docking station Icy Box
- Cradle/docking station Sharp
- Cradle/docking station Nedis
- Cradle/docking station Thomson
- Cradle/docking station Gembird
- Cradle/docking station Lenco
- Cradle/docking station Pyle
- Cradle/docking station Livoo
- Cradle/docking station Caliber
- Cradle/docking station Klip Xtreme
- Cradle/docking station SilverStone
- Cradle/docking station Renkforce
- Cradle/docking station Rapoo
- Cradle/docking station Sharkoon
- Cradle/docking station Targus
- Cradle/docking station Blaupunkt
- Cradle/docking station Lenovo
- Cradle/docking station Manhattan
- Cradle/docking station Energy Sistem
- Cradle/docking station Harman Kardon
- Cradle/docking station Trust
- Cradle/docking station Lava
- Cradle/docking station Denver
- Cradle/docking station Tripp Lite
- Cradle/docking station Hama
- Cradle/docking station Sonos
- Cradle/docking station Kensington
- Cradle/docking station Brigmton
- Cradle/docking station Denon
- Cradle/docking station Techly
- Cradle/docking station Connect IT
- Cradle/docking station Steren
- Cradle/docking station Polk
- Cradle/docking station Bose
- Cradle/docking station Audiosonic
- Cradle/docking station SBS
- Cradle/docking station Fresh N Rebel
- Cradle/docking station Muse
- Cradle/docking station Bigben Interactive
- Cradle/docking station Jam
- Cradle/docking station Digitus
- Cradle/docking station Lamax
- Cradle/docking station Ion
- Cradle/docking station Roberts
- Cradle/docking station Peavey
- Cradle/docking station Dual
- Cradle/docking station NGS
- Cradle/docking station Jabra
- Cradle/docking station IDance
- Cradle/docking station Speed-Link
- Cradle/docking station Naxa
- Cradle/docking station Fantec
- Cradle/docking station Konig
- Cradle/docking station Ices
- Cradle/docking station Trevi
- Cradle/docking station Sogo
- Cradle/docking station Peaq
- Cradle/docking station Nevir
- Cradle/docking station Leitz
- Cradle/docking station Roadstar
- Cradle/docking station Scott
- Cradle/docking station JLab
- Cradle/docking station Difrnce
- Cradle/docking station Ewent
- Cradle/docking station Wentronic
- Cradle/docking station Satechi
- Cradle/docking station Iluv
- Cradle/docking station Monitor Audio
- Cradle/docking station Vorago
- Cradle/docking station Avanca
- Cradle/docking station MIPRO
- Cradle/docking station SPC
- Cradle/docking station Xoro
- Cradle/docking station Gabor
- Cradle/docking station Monster
- Cradle/docking station Icy Dock
- Cradle/docking station Boompods
- Cradle/docking station Dreamgear
- Cradle/docking station Vantec
- Cradle/docking station HMDX
- Cradle/docking station Soundfreaq
- Cradle/docking station StarTech.com
- Cradle/docking station DAP Audio
- Cradle/docking station Logic3
- Cradle/docking station Vimar
- Cradle/docking station Kogan
- Cradle/docking station Promate
- Cradle/docking station Lotronic
- Cradle/docking station White Shark
- Cradle/docking station Socket Mobile
- Cradle/docking station Microlab
- Cradle/docking station Leotec
- Cradle/docking station Voxx
- Cradle/docking station SACK It
- Cradle/docking station I-Tec
- Cradle/docking station Acme Made
- Cradle/docking station Best Buy
Últimos Cradle/docking station Manuales
18 Septiembre 2024
18 Septiembre 2024
17 Septiembre 2024
17 Septiembre 2024
17 Septiembre 2024
14 Septiembre 2024
12 Septiembre 2024
12 Septiembre 2024
12 Septiembre 2024
12 Septiembre 2024