CyberData Systems SIP-enabled IP V2 Manual de Usario

CyberData Systems Vocero SIP-enabled IP V2

Lee a continuación 📖 el manual en español para CyberData Systems SIP-enabled IP V2 (4 páginas) en la categoría Vocero. Esta guía fue útil para 2 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/4
Quick Start Guide 930398E
The IP Endpo int Company
1.0 Out-of-Box and Prior to Final Installation
1.1. Verify that you have received all of the parts listed on the Installation Quick
Reference placemat.
1.2. Download the current manual, otherwise known as an Operation Guide,
which is available on the Documentation page at the following website
address:
http://www.cyberdata.net/products/voip/digitalanalog/ceilingspkr2/docs.html
Note You can also navigate to the Documentation page by going to
www.CyberData.net and following the steps that are indicated by
the following figures:
2.0 Select Power Source
PoE Switch PoE Injector
Set PoE power type to Class 0 = 15.4W CAT6 cable recommended—
for longer distances
Be sure you are using a non-PoE switch or port
Make sure port is not in trunk mode
Set port to full duplex/ 100mbps
Spanning Tree Protocol (STP) must be disabled or Portfast enabled
2
3
1
VoIP V2 Ceiling Speaker
Quick Start Guide
Quick Start Guide 930398E
3.0 Power Test
3.1. Plug in the CyberData device and monitor the LED activity on the front of
the device. See the following figure:
3.2. The GREEN power/status LED and the YELLOW network LED come on
immediately. The YELLOW network LED will blink to indicate network
traffic. After about 27 seconds, the GREEN power/status LED will blink
twice to indicate that the board is fully booted.
If there is no DHCP server available on the network, it will try 12 times with
a three second delay between tries and eventually fall back to the
programmed static IP address (by default 10.10.10.10). This process will
take approximately 80 seconds.
3.3. When the device has completed the initialization process, press and hold the
RTFM switch for 3 seconds to announce the IP address.
This concludes the power test. Go to Section 4.0, "Connecting to a Network
in a Test Environment".
Speaker
Status
(Green LED)
Network
Link/Activity
(Yellow LED)
Quick Start Guide 930398E
4.0 Connecting to a Network in a Test Environment
Note The following connections are usually needed for this procedure:
• PC
PoE switch or injector
CyberData device
4.1. In a test environment, use a PC that is connected to the same switch as a
single CyberData device. Note the subnet of the test PC.
4.2. Use the CyberData Discovery Utility program to locate the device on the
network. You can download the Discovery Utility program from the
following website address:
http://www.cyberdata.net/support/voip/discovery_utility.html
4.3. Wait for initialization to complete before using the Discovery Utility
program to scan for a device. The device will show the current IP address,
MAC address, and serial number.
4.4. Select the device.
Note If the IP address of the device is in the same subnet of the PC, then
go to Step 4.7.
4.5. If the IP address of the device is different from the subnet of the PC, then
complete the following steps:
4.5.1. Click the Details tab.
4.5.2. Click Adv. Config to manually configure settings with an available IP
address in the same subnet.
Note A gateway address of 0.0.0.0 or a subnet address of
255.255.255.255 will prompt you to enter a valid address.
4.5.3. Click OK after you are finished making changes.
4.6. A dialog box will prompt you to click OK after confirming the configuration
changes and will ask you to wait while the device reboots. Please wait for
the device to power up and wait for the Discovery Utility program to find
the device on the network.

Especificaciones del producto

Marca: CyberData Systems
Categoría: Vocero
Modelo: SIP-enabled IP V2

¿Necesitas ayuda?

Si necesitas ayuda con CyberData Systems SIP-enabled IP V2 haz una pregunta a continuación y otros usuarios te responderán




Vocero CyberData Systems Manuales

Vocero Manuales

Últimos Vocero Manuales