CyberPower OL6KRT2UTFHWIOR Manual de Usario

CyberPower No categorizado OL6KRT2UTFHWIOR

Lee a continuación 📖 el manual en español para CyberPower OL6KRT2UTFHWIOR (13 páginas) en la categoría No categorizado. Esta guía fue útil para 7 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/13
Users Manual
Step-Down Transformer
OL6KRT2UTF HWIO
OL10KRT2UTF HWIO
OL6KRT2UTF R HWIO
OL10KRT2UTF R HWIO
CyberPower Systems (USA), Inc.
4241 12th Avenue East Suite 400 Shakopee, MN 55379
Phone: 877-297-6937
Fax: 952-403-0009
www.CPSww.com
K01-0000 -01 362
Copyright © 2014 CyberPower Systems, Inc.
OVERVIEW
1
The CyberPower Step-Down and Isolation Transformers support installation with hardwire ( 6KRT2UTF OL10KRT2UTF OL HWIO / HWIO /
OL6KRT2UTF R OL10KRT2UTF R), and are designed for variety of CyberPower UPS systems. When combin with the UPS, the Step-Down HWIO / HWIO a ed
configuration convert voltage from 200-240V down to 100-12s 0V. The Isolation configuration provides the UPS and connected equipment from any outside
utility line fluctuations or interference.
2U Step-Down and Isolation Transformer
User’s manual Registration card
Rackmount left rail Rackmount right rail
Tie plate (1) * 1 set
2U Rackmount ears (Stands) (2) * 1 set
Input/output terminal block cover (1)
Flat head screws M5X8L (8) * 1 set :
Pan head screws M5X12L (12) * 1 set :
Plastic washers (8) * 1 set
Screw hole dust covers (10) * 1 set
Cable for 6K UPS output 6K STF i connection (1) to nput
(Only for 6K STF)
Conduits with internal wires for 8K/10K UPS output to
10K STF input connection (1)
(Only for 10K STF)
Cable glands (2)
UNPACKING
Copyright © 2014 CyberPower Systems, Inc.
HARDWARE INSTALLATION
2
HARDWARE INSTALLATION
These versatile Step-Down Transformers can be mounted in a rackmount
or vertical tower orientation. This versatility is especially important to
growing organizations with changing needs that value having the option
to position a Step-Down Transformer on a floor or in a rackmount system.
Please follow the instructions below for the respective mounting met s.hod
SAFETY PRECAUTIONS
CAUTION! To prevent the risk of fire or electric shock, only use the
supplied hardware to attach the mounting brackets.
RACKMOUNT INSTALLATION
Step 1: Rackmount e s installation ar
Attach the two rackmount e s to the Step-Down Transformer using the ar
provided screws M5X8L*8pcs.
Step 2: Rackmount rail Installation
The rails adjust to mount in 48-cm (19-inch) panel racks from to 52
91.5cm (20.5 to inches) deep Select the proper holes in the rack for 36 .
positioning the Step-Down Transformer in the rack. The 2U Step-Down
Transformer takes up position 1 through position 6. The 3U Step-Down
Transformer takes up position 1 through position 9.
Step 3 Adjust rackmount rails to fit your rack :
Attach the rackmount rail to your rack with two M5X12L screws and two
plastic washers at the front of the rack. (Located in position 1 & position 6)
Do not tighten the screws. Adjust the rail size on the rail assembly of your
rack. Secure the rail to the rear of the rack with two M5X12L screws and
two plastic washers. Tighten all screws at the front and rear of the rail.
Place the Step-Down Transformer on a flat stable surface with the front of
the unit facing toward you. Secure the Step-Down Transformer to your
rack with four M5X12L screws at the front of the rack. The 2U Step-Down
Transformer takes up position 2 through position 5. The 3U Step-Down
Transformer takes up position 2 through position 8.
CAUTION! T Step-Down Transformer must be installed above the he
power module.

Especificaciones del producto

Marca: CyberPower
Categoría: No categorizado
Modelo: OL6KRT2UTFHWIOR

¿Necesitas ayuda?

Si necesitas ayuda con CyberPower OL6KRT2UTFHWIOR haz una pregunta a continuación y otros usuarios te responderán




No categorizado CyberPower Manuales

No categorizado Manuales

Últimos No categorizado Manuales