City 24 BIC-II
Lee a continuación 📖 el manual en español para De Dietrich City 24 BIC-II (12 páginas) en la categoría Caldera. Esta guía fue útil para 14 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/12
City 1.24/II Chimney and VMC - City 1.24/II FF
City 2.24/II Chimney and VMC - City 2.24/II FF - City 2.28 FF
City 3.24/II Chimney - City 3.24/II FF
City 24 BIC/II - City 24 BIC/II FF
City Condens 1.24, 2.24, 3.24
Wall-hung gas boilers
Instructions for
use
English
31/08/05
2CITY 31/08/05 - 300005627-001-A
Thanks
Congratulations on choosing a DE DIETRICH product, a product of quality. We strongly recommend that you read the following instructions in
order to guarantee the optimal operation of your appliance. We are sure that you will not be disappointed and that it will satisfy all of your
expectations. Recommendations
For a proper operating of the boiler, follow carefully the
instructions.
The installation and the first start-up must be performed by a qualified
professional. Any work on the gas valve unit is authorised only if
carried out by a qualified professional.
Aeration
France: the cross section of the aeration vent, which is compulsory
in the premises in which the boiler is installed, must comply with the
DTU 61.1 (P 45204) standard and, in particular, with the instruction
on general improvement work (Book 1764 April 1982).
The air inlet into the premises must in no event be
obstructed, even partially.
Maintenance
The servicing and cleaning of the boiler and the sweeping of the flue
gas pipe and the bleed pot must be done at least once a year by a
qualified professional. We recommend that you take out a
maintenance contract.
Precautions against frost
The boiler is fitted with an antifreeze system. In the event of total
shutdown of the heating in winter which may lead to the danger of
freezing (switching off of radiators and current), we recommend using
a correctly dosed anti-freeze product to stop the heating water
freezing. Failing this, drain the installation completely (in all cases,
consult your fitter).
Control panel (City 1.24/II, 2.24/II, 3.24/II, 24 BIC/II)
ATemperature display
BDomestic hot water temperature maintenance override button
CSafety shutdown light
DUnlock button
E"Chimney sweep" button
F"Fitter" button
G3-position switch
H"Heating" on light
IHeating temperature setting
JFlame presence light
KSetting the domestic water temperature
L"Domestic hot water" on light
MPressure indicator
3
31/08/05 - 300005627-001-A CITY
Operating instructions
- Check that the boiler is connected to the electricity.
- Open the gas valve (See next page).
G : Switch
Turn the switch to the desired operating mode :
8 . : Boiler stopped (with antifreeze protection)
" : Boiler in use : Heating; production of domestic hot water *
(recommended mode)
: Boiler in use : production of domestic hot water Only *
I : Setting button
Adjust the heating water temperature
- Stop to the left : = 40 °C
- Hard point : = 75 °C
- Stop to the right : = 90 °C
K : Setting button *
Adjust the domestic hot water temperature
- Stop to the left : = 40 °C
- Hard point : = 53°C to 55 °C depending on the model
- Stop to the right : = 58°C to 60°C depending on the model
B : Domestic hot water temperature maintenance override
button
For City with Easymatic or Easyradio control unit
Pressing for 1 second in summer or summer/winter mode overrides
loading of the domestic hot water tank or of the primary storage tank
outside the time slot programmed on the control unit up to midnight
(indicator light B2 flash)
Light B1 lit : The burner is ignited to reheat the domestic hot
water tank (or primary storage tank)
Light B2 off : No override or programme running
Light B2 lit : Comfort programme activated
For City without control unit
Light B1 lit : The burner is ignited to reheat the domestic hot water
tank (or primary storage tank)
A power cut does not modify the selected operating mode.
D : Unlock button
If the boiler has locked itself out (warning light C lit), press button D
to re-ignite it. If a 2nd reset turns out to be necessary and remains
unsucessful, consult your fitter.
M : Pressure indicator
Displays the pressure in the heating circuit from 0.5 to 2.5 bar. If the
red warming light (0.5 bar) is lit, top up with water using the filling
system (disconnector, consult your fitter (See next page).
E and F : "Chimney sweep" button and "Fitter" button
These 2 buttons are for use only by the fitter.
Boiler ignition may be provoked by :
- A request for heat from the room thermostat, if being used.
- A request for heat by the boiler thermostat (Setting button I).
- Drawing off dometic hot water or a request for heat by the tank*.
- Temperature maintenance in the primary storage tank (City 2.24/
II).
* only for boilers with tank and City 2.24/II.
Especificaciones del producto
Marca: | De Dietrich |
Categoría: | Caldera |
Modelo: | City 24 BIC-II |
¿Necesitas ayuda?
Si necesitas ayuda con De Dietrich City 24 BIC-II haz una pregunta a continuación y otros usuarios te responderán
Caldera De Dietrich Manuales
4 Septiembre 2024
13 Agosto 2024
13 Agosto 2024
13 Agosto 2024
Caldera Manuales
- Caldera ATAG
- Caldera AEG
- Caldera Inventum
- Caldera Junkers
- Caldera Remeha
- Caldera Siemens
- Caldera Vaillant
- Caldera A.O. Smith
- Caldera ACV
- Caldera Agpo Ferroli
- Caldera Ariston
- Caldera Truma
- Caldera Eldom
- Caldera Buderus
- Caldera Elco
- Caldera Viessmann
- Caldera Itho-Daalderop
- Caldera TTulpe
- Caldera Bulex
- Caldera Quooker
- Caldera Thermex
- Caldera Eccotemp
- Caldera Thermor
- Caldera LEMET
- Caldera Oertli
- Caldera Benekov
- Caldera Worcester-Bosch
- Caldera Schafer Heiztechnik
Últimos Caldera Manuales
22 Octubre 2024
21 Octubre 2024
20 Octubre 2024
20 Octubre 2024
19 Octubre 2024
14 Octubre 2024
23 Septiembre 2024
15 Septiembre 2024
15 Septiembre 2024
15 Septiembre 2024