DIGITUS® All in One UPS system
User Manual
DN-170110 • DN-170111
Safety Warning
1. The UPS utilizes voltages that may be hazardous. Do not
attempt to disassemble the unit. The unit contains no user
serviceable parts. Only factory service personnel may perform
repairs.
2. Internal battery voltage is 12Vdc. sealed, lead-acid, 6 cells
battery.
3. Connection to any other type of receptacle other than a
two-pole, three-wire grounded receptacle may result in shock
hazard as well as violating to local electrical codes.
4. In the event of an emergency, press the OFF button and
disconnect the power cord from the AC power supply to properly
disable the UPS.
5. Do not allow liquids or any external objects to enter the UPS. Do
not place beverages or any other liquid-containing vessels on or
near the unit.
6. This unit is designed for installation in a controlled environment
(temperature controlled, indoor are free of conductive
contaminants). Avoid installing the UPS in locations where there
is static or flowing water, or excessive humidity.
7. Do not plug the UPS input into its own output.
8. Do not attach a power strip or surge suppressor to the UPS.
9. Do not connect non-computer-related items, such as medical
equipment, life-support equipment, microwave ovens, or
vacuum cleaners to UPS.
10. To reduce the risk of overheating the UPS, do not cover the UPS
cooling vents and avoid exposing the unit to direct sunlight or
installing the unit near heat emitting appliance such as air
heaters or furnaces.
11. Unplug the UPS prior to cleaning and do not use liquid or spray
detergent.
12. Do not dispose the batteries into fire as they may explode.
13. Do not open or mutilate the battery or batteries. Released
electrolyte is harmful to the skin and eyes. It may be toxic.
14. A battery can present a risk of electrical shock and high short
circuit current. The following precautions should be observed
when working on batteries:
2
Remove watches, rings, or other metal objects from the hands.
Use tools with insulted handles.
Wear rubber gloves and boots.
Do not lay tools or metal parts on the top of batteries.
Disconnect charging source prior to connecting or disconnecting
batteries terminals.
15. Servicing of batteries should be performed or supervised by
personnel knowledgeable of batteries and the required
precautions. Keep unauthorized personnel away from batteries.
16. When replacing batteries, replace with the same number and
type of sealed lead-acid battery. The maximum ambient
temperature rating is 40°C.
17. This pluggable type A equipment with battery already installed
by the supplier is operator installable and may be operated by
laymen.
18. During the installation of this equipment it should be assured
that the sum of the leakage currents of the UPS and the
connected loads does not exceed 3.5mA.
19. Beware of possibility of electric shock when disconnecting of
this unit from the mains, hazardous voltage still may be
accessible through supply from battery. The battery supply
should be therefore disconnected from the plus and minus pole
of the battery when maintenance or service work inside the UPS
is necessary.
20. The mains socket outlet that supplies the UPS shall be installed
near the UPS and shall be easily accessible.
3

Especificaciones del producto

Marca: Digitus
Categoría: Unión Postal Universal
Modelo: DN-170111

¿Necesitas ayuda?

Si necesitas ayuda con Digitus DN-170111 haz una pregunta a continuación y otros usuarios te responderán




Unión Postal Universal Digitus Manuales

Unión Postal Universal Manuales

Últimos Unión Postal Universal Manuales