doepfer System A - 100 Digital Noise Generator A-117
1
1. Introduction
Module A-117 (DNG) is a combination module, inclu-
ding a digital noise generator and an 808 source.
The digital noise generator uses random sequences of
square waves, (18-band, with multiple slewed feed-
back loops), whose rate can go from random clicks to
pure noise. The colour of the noise is very different
from the analog noise produced by the A-118.
In addition to a manual setting, the rate can be control-
led by an external clock - eg. VCO, LFO or MIDI clock).
The 808 Source aims to re-create the sort of multi-
oscillator array that was used in Roland’s TR-808
and 606 drum machines as the basis of the sound of
the hi-hat, cymbals and cowbell. The cowbell mix
uses two oscillators, and the cymbals mix six.
Rate
Noise/
Clock Out
A-117
DNG / 808
Ext.
Clock In
Mix 2
Mix 6
A-117 Digital Noise Generator System A - 100 doepfer
2
2. DNG / 808 - Overview Controls:
1 Rate : Pulse rate control for random clock /
noise output !
In / Outputs:
! DNG / RND CLK : Output for random clock / digital
noise
" EXT. CLK : Input for external clock signal
§ 6 Osc. : Output for 808 source (6 oscillators)
$ 2 Osc. : Output for 808 source (2 oscillators)
DNG
Rate
DNG /
RND CLK
DIG. NOISE/ 808 Source
0 10
6 Oscillators
EXT. CLK
2 Oscillators
808 Sound Source
➊
➋
➌
➍
➀
doepfer System A - 100 Digital Noise Generator A-117
3
3. Controls
1 Rate
This is used to adjust the pulse rate of the random
clocks generated. At low pulse rates, individual pulses
can be heard (see Fig.1, top), but with higher pulse
rates (see Fig.1, bottom) the sound merges into noise.
Fig. 1: A-117 output signals at different pulse rates
4. In / Outputs
! DNG / RND CLK
Output !
!!
! produces random clock pulses or digital
noise, depending on the pulse rate set.
" EXT. CLK
Input " is a normalled socket, so that the rate knob
controls pulse rate, unless a signal is patched into this
socket.
This external clock can be provided eg., by a square
wave from a VCO or LFO, or from a MIDI clock, etc.. In
this case, control 1 has no effect. Pulse rate is then
simply decided by the frequency of the external clock.
§ 6 Oscillators
Output § delivers a six-oscillator mix, like the raw
material of the TR-808’s cymbal sound.
$ 2 Oscillators
Output $ delivers a two-oscillator mix, like the raw
material of the cowbell sound on the Roland TR-808.
DNG/
Clock
Out
DNG/
Clock
Out
Especificaciones del producto
Marca: | Doepfer |
Categoría: | No clasificado |
Modelo: | A-117 |
¿Necesitas ayuda?
Si necesitas ayuda con Doepfer A-117 haz una pregunta a continuación y otros usuarios te responderán
No clasificado Doepfer Manuales
28 Agosto 2024
No clasificado Manuales
- No clasificado LG
- No clasificado Sanus
- No clasificado Liftmaster
- No clasificado ATen
- No clasificado Dormakaba
- No clasificado WMD
- No clasificado Martin
- No clasificado POLARIS
- No clasificado Mean Well
- No clasificado Urbanista
- No clasificado Microchip
- No clasificado Lifan
- No clasificado Lindy
Últimos No clasificado Manuales
3 Septiembre 2024
3 Septiembre 2024
3 Septiembre 2024
2 Septiembre 2024
1 Septiembre 2024
31 Agosto 2024
31 Agosto 2024
31 Agosto 2024
30 Agosto 2024
29 Agosto 2024