User’s Guide
UPS 8 – 10 kVA,
230V 50/60 Hz output
(1-phase input)
&
UPS 8 – 15 kVA,
230V 50/60 Hz output
(3-phase input)
Copyright 2007
The contents of this manual are the copyright of the publisher and may not be
reproduced (even extracts)
unless permission granted.
Every care has been taken to ensure the accuracy of
the information contained in this manual, but no liability
can be accepted for any errors or omission. The right
to make design modifications is reserved.
UPS 8 – 10 kVA, 230V 50/60 Hz output (1-phase input)
UPS 8 – 15 kVA, 230V 50/60 Hz output (3-phase input)
User’s Guide 1022403 revision D
Contents
1. Safety instructions ............................................................................................................................................................. 4
Audience .............................................................................................................................................................................. 4
CE marking ........................................................................................................................................................................... 4
User precautions ................................................................................................................................................................. 4
Environment ......................................................................................................................................................................... 5
Inquiries ................................................................................................................................................................................ 5
2. Mechanical installation .................................................................................................................................................... 6
Delivery check ..................................................................................................................................................................... 6
Unpacking and visual inspection ..................................................................................................................................... 6
3. Planning before installation ............................................................................................................................................. 8
4. Cabinet installation ........................................................................................................................................................... 9
Maiantenance bypass switch ........................................................................................................................................... 9
Transformer option ............................................................................................................................................................. 11
External battery cabinet option ........................................................................................................................................ 12
Battery racks ....................................................................................................................................................................... 12
5. Electrical installation ........................................................................................................................................................ 13
Power cables and protective fuses ................................................................................................................................. 14
Wiring procedure ................................................................................................................................................................ 15
External Battery Cabinet (EBC) installation procedure ................................................................................................ 21
6. Software and connectivity ................................................................................................................................................ 24
Communication cables ....................................................................................................................................................... 24
Connection to the standard RS-232 port (X53) ............................................................................................................... 24
LanSafe software ........................................................................................................................................................... 25
External control connections ............................................................................................................................................ 25
Emergency Power Off (EPO) ......................................................................................................................................... 26
Relay outputs ................................................................................................................................................................... 26
Programmable signal inputs ......................................................................................................................................... 27
XSlot communication (option) ........................................................................................................................................... 28
Web/SNMP Module (optional) ..................................................................................................................................... 28
AS400 Relay Module (optional) .................................................................................................................................... 29
Single Serial Port Module (optional) ........................................................................................................................... 29
Modus/Jbus Module (optional) .................................................................................................................................... 29
7. User operations ................................................................................................................................................................... 30
Display functions ................................................................................................................................................................. 30
User Settings ....................................................................................................................................................................... 31
Configuring user settings .............................................................................................................................................. 33
Changing language ........................................................................................................................................................ 33
Changing charging current ........................................................................................................................................... 33
Using relay outputs ........................................................................................................................................................ 33
Normal start-up ................................................................................................................................................................... 34
Battery start-up ................................................................................................................................................................... 34
Start-up after EPO ............................................................................................................................................................... 34
Shutdown ............................................................................................................................................................................. 35
8. Maintenance ....................................................................................................................................................................... 36
Regular service/intervals ................................................................................................................................................... 36
Batteries ........................................................................................................................................................................... 36
Cooling fan ....................................................................................................................................................................... 37
LED Indicators ..................................................................................................................................................................... 37
Maintenance bypass switch (MBS) operation .............................................................................................................. 37
Turn UPS from normal mode to mechanical bypass ................................................................................................ 38
Turn UPS from mechanical bypass to normal mode ................................................................................................ 39
9. Parallel systems ................................................................................................................................................................. 41
Overview ............................................................................................................................................................................... 41
Tie cabinets .......................................................................................................................................................................... 42
XSlot Hot Sync card: installing and wiring ..................................................................................................................... 46
Parallel operations .............................................................................................................................................................. 47
10 Recycling the used UPS or batteries .............................................................................................................................. 49
11. Dimensional drawings ...................................................................................................................................................... 50
12. Technical data ..................................................................................................................................................................... 52
Standards ............................................................................................................................................................................ 52
Environment ......................................................................................................................................................................... 52
Mechanical configuration ................................................................................................................................................. 52
Characteristics .................................................................................................................................................................... 52
AC input ................................................................................................................................................................................ 53
DC circuit .............................................................................................................................................................................. 53
AC output .............................................................................................................................................................................. 53
13. Warranty ............................................................................................................................................................................... 54
Especificaciones del producto
Marca: | Eaton |
Categoría: | Unión Postal Universal |
Modelo: | Powerware 9155-10-S-25-64x9Ah |
¿Necesitas ayuda?
Si necesitas ayuda con Eaton Powerware 9155-10-S-25-64x9Ah haz una pregunta a continuación y otros usuarios te responderán
Unión Postal Universal Eaton Manuales
11 Octubre 2024
12 Septiembre 2024
11 Septiembre 2024
22 Agosto 2024
16 Agosto 2024
12 Agosto 2024
10 Agosto 2024
9 Agosto 2024
7 Agosto 2024
5 Agosto 2024
Unión Postal Universal Manuales
- Unión Postal Universal AEG
- Unión Postal Universal IKEA
- Unión Postal Universal HP
- Unión Postal Universal Apc
- Unión Postal Universal Lenovo
- Unión Postal Universal Tripp Lite
- Unión Postal Universal Energenie
- Unión Postal Universal Voltcraft
- Unión Postal Universal Adj
- Unión Postal Universal Digitus
- Unión Postal Universal LevelOne
- Unión Postal Universal CyberPower
- Unión Postal Universal Block
- Unión Postal Universal Avocent
- Unión Postal Universal Minuteman
- Unión Postal Universal Maruson
- Unión Postal Universal V7
- Unión Postal Universal Phoenix Contact
- Unión Postal Universal Puls Dimension
- Unión Postal Universal Salicru
- Unión Postal Universal Equip
- Unión Postal Universal Murr Elektronik
- Unión Postal Universal Altronix
- Unión Postal Universal Ditek
- Unión Postal Universal Bxterra
- Unión Postal Universal Middle Atlantic
- Unión Postal Universal FSP
- Unión Postal Universal Atlantis Land
- Unión Postal Universal PowerWalker
- Unión Postal Universal FSP/Fortron
- Unión Postal Universal Online USV
Últimos Unión Postal Universal Manuales
24 Octubre 2024
22 Octubre 2024
22 Octubre 2024
22 Octubre 2024
20 Octubre 2024
18 Octubre 2024
18 Octubre 2024
12 Octubre 2024
12 Octubre 2024
12 Octubre 2024