General Introduction
The Wireless Keyfob is used to Arm, Partial Arm and Disarm the system. The
Keyfob also incorporates a Panic switch that will immediately initiate a Full Alarm
condition when the system is Armed or Disarmed.
Product Overview
A LED indicator
B Arm
C Partial Arm
D Disarm
E Panic Switch
F Key Chain Ring
G Negative Polarity
H Positive Polarity
Binding
1.
Remove the battery cover behind the keyfob.
2.
Prepare the CR2032 coin cell battery by removing any plastic wrapping on the
battery. Do not insert the batteries yet into the unit.
3.
Log into the ELRO Smart Home Alarm account from a web browser.
4.
Select “System”, then “Add a New Device”.
5.
Select “Keyfob”.
6.
The following screen will appear. This means the gateway is entering binding
mode.
2
7.
Insert the battery ensuring that the +v terminal faces upwards away from the
PCB and replace the battery cover.
8.
The screen below will appear in 10 seconds if the process is successful.
9.
Time-out will occur if the binding process was unsuccessful. Please refer to the
“Manual binding” section.
Manual Binding
1. With the battery inserted, repeat steps 3 to 6 of the Binding with Homesys
3.
Within 5 secs, the LED indicator then stop flashing and turn off, indicating the
learning procedure is completed. The screen below will appear indicating the
process is successful.
4.
If after 30 seconds LED flashes rapidly for 3 times, it means the keyfob fails the
binding process
Operation & Testing
Operating the Keyfob
There are 5 operating modes provided by the keyfob.
1.
ARM : Press and release the ARM button.
2.
DISARM : Press and release
3.
PARTIAL ARM 1: Press and release the Partial Arm button once
4.
PANIC: Slide the Panic Switch and hold for at least 3 secs before releasing.
Note: The LED on the keyfob will turn green after button press is released. This
implies the keyfob receives a confirmation signal from the Gateway. Instead if the
LED turns red, this means the keyfob did not receive the reply from gateway
Testing the Keyfob
section.
2. Press and hold the Disarm button for more than 3 seconds until the LED flashes
1.
Press the Arm button to see if there is an entry in the LOGS page of your
ELRO Smart Home Alarm account.
moderately (on for 2 second; off for 2 second). This implies keyfob has now
entered the binding mode and is waiting to receive binding signals from the
gateway.
2.
Press the Partial Arm button to see if there is an entry in the LOGS page of your
ELRO Smart Home Alarm account.
3.
Press the Disarm button to see if there is an entry in the LOGS page of your
ELRO Smart Home Alarm account.
4.
Slide the Panic Switch and hold for at least 3 secs before releasing. See if there
is an entry in the LOGS page of your ELRO Smart Home Alarm account.
Note: Press the Disarm button to deactivate a triggered alarm and siren sound.
3
Maintenance
Low Battery: When the battery becomes low, the LED will turn orange after
each press to indicate low battery condition to the user. Replace the battery
when this occurs.
Troubleshooting
The troubleshooting table lists some possible causes and solutions. Please contact
your original retailer or nearest service center if the below solutions cannot solve
your problem.
Specifications
Battery
CR2032 3V/230mAh
Operating Frequency
868MHz
Operating Temperature
-10°C to 40°C
RF Output power
< 25mW
** Specifications are subject to change without notice.
WARNING:
Do not dispose of electrical appliances as unsorted municipal waste, use separate
collection facilities instead. Please contact your local government for information
regarding the collection systems available.
If electrical appliances are disposed of in landfills or dumps, hazardous substances
can leak into the groundwater and get into the food chain, damaging your health
polarity.
1.
out of range of and well-being.
When replacing old appliances with new once, the retailer is legally obligated to
take back your old appliance for disposal at least for free of charge.
LED Table
The table below summarizes the LED indication of the keyfob.
Function LED Indication
RF transmission Green LED illuminating for 1 second
Failed RF transmission Red LED illuminating for 1 second
Low battery Orange LED illuminating for 1 second
Binding in process LED flashing with an interval of 2 seconds
Binding successful Green LED illuminating for 0.5 seconds
Binding timeout Green LED flash 3 times.
Reset to Factory Settings
1.
Remove the battery from the keyfob.
2.
Using two fingers, press and hold both the Arm and Disarm simultaneously
while inserting the battery.
3.
Keep pressing both buttons for more than 5 secs until the detector’s LED blinks
red, this implies the device is reset back to factory mode.
Note: After power on, the Keyfob will automatically enter “Auto-binding” mode
to bind with a gateway. The auto-binding process lasts for 30 seconds
indicated by the LED blinking slowly.
Symptom
Cause of Failure
Recommendation
LED cannot be
displayed
1.
Run out of battery
power.
2.
Check if reverse battery
1.
Replace a new battery.
2.
Refit the battery with correct
polarity.
LED turns red after
pressing the button
Keyfob is
the gateway.
1.
Move closer to the gateway
2.
Hold the keyfob higher and
press again.
LED blinks green
slowly for 30secs after
power on.
1. Keyfob has not bind
with Gateway
1. Remove the battery and
perform binding
Especificaciones del producto
Marca: | Elro |
Categoría: | Seguridad |
Modelo: | AS80RE11 |
¿Necesitas ayuda?
Si necesitas ayuda con Elro AS80RE11 haz una pregunta a continuación y otros usuarios te responderán
Seguridad Elro Manuales
17 Septiembre 2024
17 Septiembre 2024
15 Septiembre 2024
4 Septiembre 2024
28 Agosto 2024
22 Agosto 2024
11 Agosto 2024
Seguridad Manuales
- Seguridad Bosch
- Seguridad Panasonic
- Seguridad Grundig
- Seguridad Honeywell
- Seguridad Siemens
- Seguridad Abus
- Seguridad Alphatronics
- Seguridad Aritech
- Seguridad Airbolt
- Seguridad Brennenstuhl
- Seguridad Hikvision
- Seguridad Nedis
- Seguridad Eminent
- Seguridad Ezviz
- Seguridad Axis
- Seguridad Theben
- Seguridad Profile
- Seguridad Trebs
- Seguridad Fenton
- Seguridad Eufy
- Seguridad Steinel
- Seguridad Somfy
- Seguridad Lamax
- Seguridad Netgear
- Seguridad Grothe
- Seguridad LevelOne
- Seguridad Unitron
- Seguridad Netatmo
- Seguridad Bticino
- Seguridad Topcraft
- Seguridad First Alert
- Seguridad Dahua
- Seguridad Foscam
- Seguridad BRK
- Seguridad Hagenuk
- Seguridad Technaxx
- Seguridad Niko
- Seguridad Gira
- Seguridad Jung
- Seguridad Wanscam
- Seguridad Geemarc
- Seguridad Dymond
- Seguridad Friedland
- Seguridad Golmar
- Seguridad Storage Options
- Seguridad Provision ISR
- Seguridad NetworX
- Seguridad Bitron Video
- Seguridad Monacor
- Seguridad Zmodo
- Seguridad Velbus
- Seguridad Electronics Line
- Seguridad HUMANTECHNIK
- Seguridad Directed Electronics
- Seguridad Oplink
- Seguridad Jablotron
- Seguridad Muller
- Seguridad Home8
- Seguridad AVTech - Velleman
- Seguridad Galaxy
- Seguridad Sonic Alert
- Seguridad Smartalarm
- Seguridad GE Security
- Seguridad Nor-tec
- Seguridad Entrya
- Seguridad Tegui
- Seguridad Iiquu
- Seguridad Woonveilig
- Seguridad Mikros
- Seguridad FlinQ
- Seguridad Myfox
- Seguridad Bellman
- Seguridad Protector
- Seguridad Ksenia
- Seguridad Mr Safe
- Seguridad Fracarro
Últimos Seguridad Manuales
24 Octubre 2024
22 Octubre 2024
21 Octubre 2024
20 Octubre 2024
20 Octubre 2024
18 Octubre 2024
18 Octubre 2024
18 Octubre 2024
5 Octubre 2024