Enviroswim ES- 3 Installation Guide
©Enviroswim 2014 Enviroswim 2014 © V3.0AU
These instructions are repeated in the Operating Manual and should be repeated every time the pool is refilled.
1. Ensure that unwanted compounds are eliminated from the water.
Parameter
Required
Notes and Treatment
Metals
<recommended for
that metal
Test unusual supplies such as bore water for excessive amounts of
metals in particular, manganese, iron and magnesium. There are
dierent recommended maximums. Remove using appropriate
sequestering agents.
Phosphates
< 100ppb/0.1ppm
Use phosphate remover.
Copper
< 0.1 ppm
Dilute or use a sequestering agent to reduce. Note: To establish the
copper ions and proportionate silver ions with the Enviroswim
process require there is no signicant residual copper in the.
2. Adjust water balance
Parameter
Minimum
Ideal Range
Maximum
pH
6.8
7.1 7.5-
7.6
Calcium
Hardness
160
200-250ppm
400
Alkalinity
50
80-150ppm
200
TDS
500
500-800ppm
1500
Do not use Cyanuric Acid (Stabliser) as this will interfere with the oxidising capability of the Enviroswim
system
Complete and return your Warranty Registration Card NOW!!
1. Balance the water as per above. Ensure all Enviroswim switches are set to OFF and variable controls (Ioniser
and ORP) at minimum (fully counter-clockwise).
2. Turn on the pool pump so that water is owing through the filtration system
and the Enviroswim ionization/oxidation chamber and ultrasonic emitter
pipe. Set the left hand switch on the Enviroswim unit to MANUAL. Make
sure that the ionization/oxidation chamber is lled with water.
3. Turn on the right hand ON/OFF switch on the control box.
4. Turn the knob on the control box under the ORP meter slowly clockwise
until the ORP meter reads between 13 - 15 Amps.
5. Turn the ioniser switch to maximum. Run the unit for approximately 1 hour
per 1000 litres of water and test copper level.
6. Perform chemical tests to determine readings for pH, ORP, alkalinity,
copper, and calcium hardness then adjust accordingly. Refer to Operating
Manual for appropriate treatments.
7. Test the copper level and when in the range 0.2-0.4 ppm set the system
for the appropriate run time and adjust the Ioniser output to around 50%.
8. Startup is now complete. Refer to the operating manual for a guide on run
times. Remember every pool is dierent. Factors that will impact runtime
are location, bather load, season, type of cover and water temperature.
When can I use the pool?
It is OK to use the pool while the Copper levels are being established provided the EnviroSwim system is
processing the water continuously and the correct water balance (pH, alkalinity and hardness) is established.
The Oxidation process will treat organic matter and as water ows through the cell it will be being treated with
concentrated Copper and Silver ions. We recommend that the water is allowed to circulate at least once (allow
1 hour per 10,000 litres) before swimming.
1. Plan layout of components
a. Check component dimensions.
b. Conrm sequence of components in water ow.
c. Check cable lengths for control box location.
d. Power Supply
2. Conrm additional materials required
a. Pipe ttings and Pipe adhesive
b. Cable ties
c. Mounting Screws
3. Tools.
a. Pipe Saw
b. Drill and Bits
Return your Warranty Registration Card to ensure
Warranty commences from installation rather than manufacturing date
Seasonal Newsletter
Rapid response to your questions
Balance Water
3. Commission
Balance Water
1. Plan 2. Install 3. Commission
1. Plan
IMPORTANT SAFETY INSTRUCTIONS
ATTENTION INSTALLER
This manual contains important information about the installation of this product. For complete instructions on
operation and safe use of this product refer to EnviroSwim ES-3 Operating Manual
READ AND FOLLOW ALL INSTRUCTIONS. IMPORTANT SAFETY INSTRUCTIONS WARNING -
PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS
To reduce the risk of injury, do not permit children to use this product unless they are closely WARNING
supervised.
When mixing acid with water, ALWAYS ADD ACID TO WATER, NEVER ADD WATER TO ACID. WARNING
There are no serviceable parts in the control box. Return to Enviroswim for service. WARNING
Do not operate electrolytic cell without proper ow or water circulation. A build-up of gases will WARNING
result in hazardous conditions.
Use of chemicals other than those recommended may be hazardous. Follow the Chemical CAUTION
Manufacturer’s Instructions.
This unit is for use with permanently installed pools. Do not use with storable pools. A CAUTION
permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily
disassembled for storage. A storable pool is constructed so that it is capable of being readily disassembled for
storage and reassembled to its original integrity.
Some modern variable speed pumps have settings that produce inadequate water ow to either ll CAUTION
the ES-3 wet cell or create sucient ow to eect the ES-3 processes. Do not allow these pumps to operate at
their minimum speed when the ES- is being operated. 3
READ ALL THESE INSTRUCTIONS
For advice phone 1300 888 457or email : info@enviroswim.com
What in the Box? ’s
1 x Enviroswim Control Unit
1 x Transparent water cell
o 1 x Titanium plate assembly
o 1 x Cu/Ag electrode
assembly
Ultrasonic Emitter assembly
Power Cable
4 x 40mm to 50mm adapters
Installation Guide (this guide)
Operating Manual (A5)
Warranty Registration Card
Copper test kit
Review
instructions next
page
©Enviroswim 2014
2. Install
Pump and Filter Heating
Mains Power supply :
240V/50 Hz 10 Amp earthed
power supply appropriately
certied by a registered
electrician.
170 00.
140.00
150mm
80mm
135mm
370mm
100mm
200mm
670mm
Maintenance Access
Maintenance Access
77.00
35.00
25 00.
40.00
50.00
Inside Diameter
Allowance for cable
attachment
37 00.
Pool Pump do not
exceed Max ratings
1.4
Metres
1.4
Metres
WARNING :
Ensure cell is mounted
oriented as shown.
Horizontal with water
ow from underneath.
Other orientations may
disable water level
sensor. Water Inow
should always be at
oxidiser end.
1.4
Metres
Ideal location suggestion. Ultrasonic Coil
may be anywhere in water ow with any
orientation.
WARNING : Do not
use primer on acrylic cell.
Actual Size Drilling Template