Fetco HWD-2105 Manual de Usario

Lee a continuación 📖 el manual en español para Fetco HWD-2105 (11 páginas) en la categoría Dispensador de agua. Esta guía fue útil para 10 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/11
Temperature On Demand US design patent applied for. Other Temperature On Demand US patents applied for.
FETCO®, is a trademark of Food Equipment Technologies Company.
© 2011 ood E uipment Techno ogies Compa yF q l n Part Number P115 April 2013
NOTICE TO INSTALLER: Please leave this book with the machine.
tf Touch Function Selector Technology
HWD-2105
Hot Water Dispenser
.
2
G
W
G
W
NEMA PLUG CONFIGURATION
NEMA 5-15P NEMA 5-20P NEMA 6-15P
FETCO
FETCO
FETCO
FETCOFETCO®
®
®
®® HWD-2105 Hot Water Dispenser
HWD-2105 Hot Water Dispenser
HWD-2105 Hot Water Dispenser
HWD-2105 Hot Water Dispenser HWD-2105 Hot Water Dispenser
Contact Information
Contact Information
Contact Information
Contact Information Contact Information
FETCO ®
Food Equipment Technologies Company
600 Rose Road
Lake Zurich IL USA • • 60047-0429
Internet: www.fetco.com
Phone: (800) 338-2699 (US & Canada)
(847) 719-3000
Fax: (847) 719-3001
Email: sales@fetco.com
techsupport@fetco.com
Description & Features
Description & Features
Description & Features
Description & Features Description & Features
W ter tem ratu e sele table to 1 8°-20 °F/ 0-9 C a pe r c 5 476° English and Metric tem erat re ran es sele tab e p u g c l
Maximum single dispense is 24ounces/700cc in 15 seconds maximum dispense time
Non-Temperature on Demand and Temperature on Demand (TOD) configurations is available as separate equipment.
Specifications
Specifications
Specifications
Specifications Specifications
Standard Electrical Configurations-DOMESTIC & CANADA
Configuration
Code
Heater
Configuration Voltage Phase Wires NEMA
Plug KW Maximum
Amp Draw Gallons/Hour
H210511 1 X 1.44 kW 120 1 2+G NEMA 5-15P 1.5 12.0 4.0 gallon*/15 liter
H210521 1 X 2.1 kW 120 1 2+G NEMA 5-20P 2.2 17.5 5.7 gallon*/22 liter
Standard Electrical Configurations-DOMESTIC & SPECIALTY
H210531 1 X 3.2 kW 200-240 1 2+G NEMA 6-15P 2.3-3.3 11.2-13.4 6-8.7gallon*/22.7-33 liter
Electrical Configurations- EXPORT & CANADA
H210541 1 X 3.2 kW 230 1 2+G Cord Only 2.9 12.8 7.8 gallon*/29.5 liter
Temperature range is selectable from 158°-207°F/70-97°C based on 207°F/97°C hot water tank temperature.
*Flow rate based on 65-70°F 18-21°C water mains supply temperature at lowest possible power supply current.
Selectable English and Metric temperature units. For EXPORT, Cord without plug will be attached
Single touch pad selectable hot water dispense temperature.
Power Plug Configurations
Pressure: 40-75 psig, (276-517kPa)
Minimum Flow Rate: 1½gpm (5.7lpm)
Water Requirements:
Water connection inlet: ¼ inch male flare fitting
NEW TECHNOLOGICAL FEATURES
The FETCO hot water dispenser uses new t
t
t
tt
f
f
f
f f Touch Function Selector Technology to operate the hot water dispenser.
The t
t
t
tt
f
f
f
f f Touch Function Selector buttons (above and below display screen) alternately dim and brighten when selection is not active.
Dispensing and Feature Selections activate when touched. The front panel is clean and uncluttered.
Programming, display and error codes are interactive and more intuitive.
Float indicator is built into drip tray to help simplify maintenance and cleaning.
NOTE:
The HWD-2105 Digital Hot Water Dispenser cannot be modified into a HWD-2105 TOD Temperature on Demand Hot Water Dispenser
Weights and Capacities
Dispenser Model Weight
(empty)
Water tank
Capacity
Weight
(filled)
Height
Inches/cm
Wide
Inches/cm
Deep
Inches/cm
Hot Water Dispenser
HWD-2105 24 lbs/10.9kg 3.2 gallon/12
liter 49 lbs/22kg 24 1/2 in/62
cm 9 in/23 cm 18 1/2 in/47 cm
NOTE: Temperature accuracy of dispensed hot water may vary up to 3 ½ % of displayed temperature selection. Factors affecting accuracy include quantity of hot
water dispensed, ambient air temperature, distance of container from hot water faucet (pouring over longer distance causes more cooling)
3
Dimensions & Utility Connections
Water inlet fitting: ¼ inch male flare fitting
Installation
Installation
Installation
Installation Installation
The installation must comply with applicable federal, state, and local codes having jurisdiction at your location. Utilize only
qualified beverage equipment service technicians for installation.
A Service Company Directory may be found on our website, http://www.fetco.com.
Setup
1. Before placing the unit, verify that it will fit in the space intended for it, and that
the counter or table will support the weight of the HWD-2105 when filled.
2. When the unit is in position, use a bubble level to level it front to back and side
to side by adjusting the legs.
Water Connection
1. Water inlet is a ¼ inch male flare fitting.
2. Install a shut off valve near the unit to facilitate service.
3. Install a backflow prevention device. A spring loaded double check valve such as a
WATTS® SD-2 or SD-3, two models accepted by most zoning authorities. The
check valve should be as close to the water supply inlet as possible.
4. An inline water filter is highly recommended. It should be installed after the water
shutoff valve and in a position to facilitate filter replacement.
5. Flush the water supply line and filter before connecting it to the unit.
6. Verify that the water line provides at least 1½ gpm (5.7lpm), and that the water
pressure is between 40-75 psig (276-517kPa).
Electrical Connection
1. Check serial number plate for the maximum wattage and verify that the actual
voltage at the electrical outlet is compatible with the unit’s specifications.
2. Plug unit in. Note that the plug is NEMA 5-15P or NEMA 5-20P (domestic).
3. The temperature and water tank fill level are pre-set at the factory and there is
no need to turn off the heater during the installation process.
The heating process will start automatically when the tank is filled enough to
cover the heating element
WARNING-Do not plug-in this equipment or attempt to operate without all covers in place all and screws fastened.
Back
p
anel of HWD-2105
Power
Switch
Water
Supply
Inlet
A
ppliance Inlet
(attach power cord)
Tank
Drain
Tank
Vent
Warning: Legs are to be adjusted
only to level the unit. Do not extend
them higher than necessary
!
Warning:
To prevent electrical shock, this
unit must be properly grounded.
!
G
W
G
W
NEMA PLUG CONFIGURATION
NEMA 5-15P NEMA 5-20P NEMA 6-15P
Drawin
g
# 1201.00001.00

Especificaciones del producto

Marca: Fetco
Categoría: Dispensador de agua
Modelo: HWD-2105

¿Necesitas ayuda?

Si necesitas ayuda con Fetco HWD-2105 haz una pregunta a continuación y otros usuarios te responderán




Dispensador de agua Fetco Manuales

Dispensador de agua Manuales

Últimos Dispensador de agua Manuales