IMPORTANT! PLEASE READ CAREFULLY AND SAVE.
This user’s manual contains important information
about your Heat Alarm’s operation. If you are installing
this Heat Alarm for use by others, you must leave this
manual—or a copy of it—with the end user.
TABLE OF CONTENTS
Basic Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
F ire Safety Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
B efore You Install This Heat Alarm 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H ow This Heat Alarm Works . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
How To Install This Heat Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
Locking Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Weekly Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Regular Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
If You Suspect a Problem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Understanding the Indicator Lights and Alarm Horn Patterns . . . . . . . . .5
If This Heat Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
What To Do In Case Of Fire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Using the Silence Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Latching Alarm Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Recommended Locations For Heat Alarms . . . . . . . . . . . . . . . . . . . . . .6-7
Locations To Avoid For Heat Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Special Compliance Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Limitations of Heat Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
© 2008 BRK Brands, Inc.
All rights reserved. Distributed by BRK Brands, Inc.
3901 Liberty Street Road, Aurora, IL 60504-8122
Consumer Affairs: (800) 323-9005
www.brkelectronics.com • www.firstalert.com
INTRODUCTION
Thank you for choosing First Alert
®for your Heat Alarm needs. You have
purchased a state-of-the-art Heat Alarm designed to provide you with early
warning of increased temperatures that may be the result a fire.
Key features include:
135º F Fixed and 15º F/Minute Rate of Rise–Programmed to alarm when
temperature reaches 135ºF or when the microprocessor senses a temperature
rise of 15º F per minute. This allows the unit to sense a heat rise and alarm
prior to reaching the fixed temperatur e of 135º F , providing a mor e rapid
response to a potential fire.
Exclusive IR* Remote Control Feature–Lets you Test or Silence the Heat
Alarm using most commonly available remote controls.
Latching Alar m Indicator–Microprocessor controlled feature automatically
identifies and remembers which unit in an interconnected series initiated an
alarm, even after the alarm condition has ended.
Two Silence Features:
1. Temporarily silences the low battery chirp for up to 8 hours without
removing the battery.
2. Temporarily silences an unwanted nuisance alarm for up to 15 minutes.
Battery Compartment–swings out for quicker, easier battery installation
even when unit is mounted.
Interconnectable–Can be interconnected with BRK Smoke Alarms.
*Infrared (IR) remote controls like those used for TV’s and VCRs.
1
USER’S MANUAL
120V AC/DC POWERED 135ºF FIXED AND
15ºF/MINUTE RATE-OF-RISE HEAT ALARM
WITH BATTERY BACK-UP
• This device is not intended to aler hearing impaired rt esidents.
Smoke Alarms specifically designed for the hearing impaired,
which featur devices like flashing strobe lights, are available e
to alert the hearing impaired in case of fire.
• Installation of this Heat Alarm must conform to the electrical
codes in your area; Articles 210 and 300.3 (B) of the National
Electrical Code (NFPA 70), NFPA 72, NFPA 101; SBC (SBCCI);
NBC (BOCA); OTFDC (CABO), and any other local or building
codes that may apply. Wiring and installation must be performed
by a licensed electrician. Failure to follow these guidelines may
result in injury or property damage.
• mThis Heat Alar is not a Smoke Alarm. This unit is not suitable
protection when used alone. Do not use this unit as the only
means of fire detection in a home. This unit is intended for use
as a supplement to Smoke Alarms.
• This Heat Alarm must have AC or battery power to operate.
If the AC power fails, batter back-up will allow the alarm toy
operate for a limited time. If AC power fails and the battery is
dead or missing, the alar cannot operate.m
• This unit must be powered by a 24-hour, 120VAC 60Hz circuit.
Be sure the circuit cannot be turned off by a switch, dimmer, or
ground fault circuit interrupter. Failure to connect this unit to a
24-hour circuit and keeping fresh batteries installed, may prevent
it from providing constant protection.
• Never disconnect the power from an AC powered unit to stop an
unwanted alarm. Doing so will disable the unit and remove your
protection. In the case of a true unwanted alarm, use the Silence
Feature by using an IR remote control or by pressing the
Test/Silence button or fan the heat away from the unit. The alarm
will reset automatically when it returns to normal operation.
• NEVER ignore any alarm. Read “If Your Heat Alarm Sounds” for
more information on how to respond to an alarm. Failure to
respond can result in injury or death.
•
Test this Heat Alarm once a week. If it ever fails to test correctly,
have it replaced immediately! If the Alarm is not working properly,
it cannot aler t you to a problem.
• Connect this Heat Alarm ONLY to other compatible units.
See “Special Requirements for Interconnected Heat Alarms” for
details. Do not connect it to any other type of alarm or auxiliary
device. Connecting anything else to this unit may damage it or
prevent it from operating properly.
• DO NOT stand too close to the unit when the alar m is sounding.
It is loud to aler t you in an emergency. Exposure to the horn at
close range may harm your hearing. When testing the unit, step
back when the horn starts sounding.
• Do not paint over the Heat Alarm. Paint may clog the openings to
the sensor and prevent the Heat Alarm from operating properly.
120V AC ~6 0 Hz
0.07Amps
FIRE SAFETY TIPS
Follow safety rules and prevent hazardous situations: 1) Use smoking
materials properly. Never smoke in bed. 2) Keep matches or lighters away
from children; 3) Store flammable materials in proper containers; 4) Keep
electrical appliances in good condition and don’t overload electrical circuits;
5 ) Keep stoves, barbecue grills, fireplaces and chimneys grease- and debris-
free; 6) Never leave anything cooking on the stove unattended; 7) Keep
portable heaters and open flames, like candles, away from flammable
materials; 8) Don’t let rubbish accumulate.
Keep alarms clean, and test them weekly. Replace alarms immediately if they
are not working properly. Heat and Smoke Alarms that do not work cannot
alert you to a fire. Keep at least one working fire extinguisher on every floor,
and an additional one in the kitchen. Have fire escape ladders or other reliable
means of escape from an upper floor in case stairs are blocked.
BEFORE YOU INSTALL THIS HEAT ALARM
IMPORTANT! Read “Recommended Locations for Heat Alarms” and
“Locations to Avoid for Heat Alarms” before beginning. This unit monitors
the air, and when heat reaches its sensing chamber, it alarms. It can give
you more time to escape before fire spreads. This unit can ONLY give an
early warning of developing fires if it is installed, maintained and located
where heat can reach it, and where all residents can hear it, as described in
this manual. This unit will not sense gas, smoke, or flame. It cannot prevent
o r extinguish fires.
Know Where To Install Your Heat Alarms
See “Recommended Locations For Heat Alarms” and “Locations To Avoid
For Heat Alarms” for details.
Know What Heat Alarms Can and Can’t Do
A Heat Alarm can help alert you to fire, giving you precious time to
escape. It can only sound an alarm once heat reaches the sensor.
See “Limitations of Heat Alarms” for details.
Check Your Local Building Codes
This Heat Alarm is designed to be used in a typical single-family home. It
alone will not meet requirements for boarding houses, apartment buildings,
hotels or motels. See “Special Compliance Considerations”
for details.
Model
HD6135FB
L ISTED TO
UL 539
STANDARD
The Mounting Bracket:
To remove the mounting bracket from the Heat
Alarm base, hold the Heat Alarm base firmly and
twist the mounting bracket counterclockwise.
The mounting bracket installs onto the junction box.
It has a variety of screw slots to fit most boxes.
The Power Connector:
The power connector plugs into a power input block on
the Heat Alarm. It supplies the unit with AC power.
• eThe black wir is “hot.”
• eThe white wir is neutral.
• The orange wire is used for interconnect.
If you need to remove the power connector, disconnect
AC power at the electrical panel; insert a flat screwdriver
blade between the power connector and the security
tab inside the power input block. Gently pry back the
tab and pull the connector free.
1
2
3
2
9
8
7
3
5
6
4
The Parts of This Unit
1 Mounting Bracket
2 Mounting Slots and Screws
3 Locking Pins (break out of bracket)
4 Hot (Black) AC Wire
5 Neutral (White) AC Wire
6 Interconnect (Orange) Wire
7 Latch to Open Battery Compartment
8 Swing-Out Battery Compartment
9 Quick-Connect Power Connector
HOW TO INSTALL THIS HEAT ALARM
THE PARTS OF THIS HEAT ALARM
This Heat Alarm is designed to be mounted on any standard wiring junction box to a 4-inch (10 cm) size, on either the ceiling or wall (if allowed by local codes).
Read “Recommended Locations For Heat Alarms” and “Locations to Avoid For Heat Alarms” before you begin installation.
Tools you will need: • Needle-nose pliers or utility knife •Standard Flathead screwdriver.
Fixed Temperature and Rate-of-Rise.
This Heat Alarm monitors the air and when heat reaches the sensor, it alarms.
The unit will alarm either when the temperature reaches a fixed 135º F (57º C) or
the microprocessor detects a 15º F (8.3º C) per minute rate of rise temperature
change. This allows the unit to sense a heat rise and alarm prior to reaching the
fixed temperature of 135º F (57º C), providing quicker response to a potential fire.
Heat Alarms are intended for use as supplemental safety devices with Smoke
Alarms. Heat Alarms are designed for use in areas where Smoke Alarms
cannot be installed due to temperature and environmental conditions, as in
unheated garages and crawl spaces. A Heat Alarm can only give early warn-
ing of a developing fire if it is properly installed and maintained and located
where heat can reach it. The unit will not sense gas, smoke or flame. Heat
Alarms cannot prevent or extinguish fires.
This Heat Alarm is approved for use in single-family residences. It is NOT
designed for marine or RV use.
THE COVER OF YOUR HEAT ALARM
1. Power Light, Test/Silence Button
2. Remote Control “Eye”: Aim an infrared
remote control at the “Eye” on the Alarm
t o test or silence the unit. (Works with
most infrared remote controls.)
3. Air Vents
4. (Behind the Cover) Alarm Horn: 85 dB
audible alarm for test, alarm, and unit
malfunction warning.
5 . Heat Sensor
1
2
3
4
5
HOW THIS HEAT ALARM WORKS
Make sure the Alarm is not receiving excessive noisy power. Examples of noisy power could be major appliances on the same circuit, power from a
generator or solar power, light dimmer on the same circuit or mounted near fluorescent lighting. Excessive noisy power may cause damage to your Alarm.
2
T he basic installation of this Heat Alarm is the similar whether you want to
install one Heat Alarm, or interconnect more than one Heat Alarm. If you
are interconnecting more than one Heat Alarm, you MUST read “Special
Requirements for Interconnected Heat Alarms” below before you begin
installation.
ELECTRICAL SHOCK HAZARD. Turn off power to the area where you
will install this unit at the circuit breaker or fuse box before beginning
installation. Failure to turn off the power before installation may result
in serious electrical shock, injury or death.
1. Remove the mounting bracket from the base. Position the screw slots
o n the mounting bracket over the screws in the junction box. Tighten
the screws.
2. Using wire nuts, connect the power connector to the household wiring.
Improper wiring of the power connector or the wiring leading to the
power connector will cause damage to the Alarm and may lead to a
non-functioning Alarm.
3. Plug the power connector into the back of the Heat Alarm.
4.
Position the base of the Alarm over the mounting bracket and turn. The
Alarm can be positioned over the bracket every 60°. Turn the Alarm
clockwise (right) until the unit is in place.
5. Check all connections.
ELECTRICAL SHOCK HAZARD. Do not restor e power until all Heat
Alarms are completely installed. Restoring power before installation is
complete may result in serious electrical shock, injury or death.
6. Make sure the Heat Alarm is receiving AC power. Under normal
operation, the green light (LED) will shine continuously.
7 . If the green power indicator light does not light,
TURN OFF POWER TO
T HE JUNCTION BOX and recheck all connections. If all connections are
correct and the power indicator still does not light when you restore the
power, the unit should be replaced immediately.
8 . Test each Heat Alarm. Press the Test/Silence button until you hear a brief
acknowledge (or feedback) chirp. The alarm will sound: 3 beeps, pause,
3 beeps, pause.
When testing a series of interconnected units you must test each
unit individually. Make sure all units alarm when each one is tested.
I f any unit in the series does not alarm, TURN OFF POWER and recheck
connections. If it does not alarm during testing when you restore power,
replace it immediately.
SPECIAL REQUIREMENTS FOR INTERCONNECTED HEAT ALARMS
• Failure to meet any of these requirements could damage the units
and cause them to malfunction, removing your protection.
Interconnected units can provide earlier warning of fire than stand-alone
units, especially if a fire starts in a remote area of the dwelling. If any unit
i n the series senses heat, all units will alarm.
Interconnect units within a single family residence only. Otherwise all house-
holds will experience unwanted alarms when you test any unit in the series.
Interconnected units will only work if they are wired to compatible units and
all requirements are met. This unit is designed to be compatible with:
First Alert®Smoke Alarm Models SA4120, SA4121B, SA4919B, SA100B
and BRK Electronics®Smoke Alarm Models 100S, 2002RAC, 4120, 4120B,
4120SB, 4919, 5919, 5919TH;
BRK Electronics®Smoke/CO Alarm Model
SC6120B.
Interconnected units must meet ALL of the following requirements:
• A maximum of 18 compatible Smoke, Heat or CO Alarms may be
interconnected. To comply with NFPA limits, no more than 12 of the
18 alarms may be Smoke Alarms.
• The same fuse or circuit breaker must power all interconnected units.
• All wiring must conform to all local electrical codes and NFPA 70 (NEC).
Refer to NFPA, Chapter 2 and/or your local building code for further
connection requirements.
FOLLOW THESE INSTALLATION STEPS
STAND-ALONE ALARM ONLY:
• Connect the white wire on the power connector to the neutral wire in
the junction box.
• Connect the black wire on the power connector to the hot wire in the
junction box.
• Tuck the orange wire inside the junction box. It is used for
interconnect only.
INTERCONNECTED UNITS ONLY:
Strip off about 1/2” (12 mm) of the plastic coating on the orange
wire on the power connector.
• Connect the white wire on the power connector to the neutral wire in
the junction box.
• Connect the black wire on the power connector to the hot wire in the
junction box.
•
Connect the orange wire on the power connector to the interconnect
wir interconnecting.e in the junction box. Repeat for each unit you are
Never connect the hot or neutral wires in the junction box to the orange
interconnect wire. Damage may result.
• Never cross-connect hot and neutral wires between interconnected
Alarms. Damage will result.
STAND-ALONE ALARM ONLY:
• If you are only installing one Heat Alarm, restore power to the
junction box.
INTERCONNECTED UNITS ONLY:
• If you are interconnecting multiple Heat Alarms, repeat steps 1-5
for each Heat Alar m in the series. When you ar e finished, restore
power to the junction box.
6
7
8
4
3
1
54
3
1
5
2
AB
}}
A. Unswitched 120VAC
60 Hz source
B. To additional units; Maximum = 18 total
(Maximum 12 Smoke Alarms)
1. Heat Alarm
2. Ceiling or Wall
3. Power Connector
4. Wire Nut
5. Junction Box
6. Neutral Wire (Wht)
7. Interconnect Wire
(Orange)
8. Hot Wire (Blk)
3
Especificaciones del producto
Marca: | First Alert |
Categoría: | Detector de humo |
Modelo: | HD6135FB |
¿Necesitas ayuda?
Si necesitas ayuda con First Alert HD6135FB haz una pregunta a continuación y otros usuarios te responderán
Detector de humo First Alert Manuales
14 Octubre 2024
1 Octubre 2024
29 Septiembre 2024
22 Septiembre 2024
17 Septiembre 2024
17 Septiembre 2024
17 Septiembre 2024
17 Septiembre 2024
14 Septiembre 2024
12 Septiembre 2024
Detector de humo Manuales
- Detector de humo Grundig
- Detector de humo Honeywell
- Detector de humo Siemens
- Detector de humo Abus
- Detector de humo Alecto
- Detector de humo AngelEye
- Detector de humo Nedis
- Detector de humo Pyle
- Detector de humo Trust
- Detector de humo Elro
- Detector de humo EMOS
- Detector de humo KlikaanKlikuit
- Detector de humo Ei Electronics
- Detector de humo Hama
- Detector de humo Smartwares
- Detector de humo ESYLUX
- Detector de humo Kidde
- Detector de humo Nest
- Detector de humo Netatmo
- Detector de humo Hager
- Detector de humo FireAngel
- Detector de humo Chacon
- Detector de humo Sygonix
- Detector de humo TFA
- Detector de humo Clas Ohlson
- Detector de humo Konig
- Detector de humo BRK
- Detector de humo Bavaria
- Detector de humo DSC
- Detector de humo Fito
- Detector de humo FirstAlert
- Detector de humo Fibaro
- Detector de humo Nexa
- Detector de humo Homematic IP
- Detector de humo REV
- Detector de humo Lanberg
- Detector de humo FireHawk
- Detector de humo X-Sense
- Detector de humo Mercury
- Detector de humo Heatit
- Detector de humo Ferguson
- Detector de humo Kogan
- Detector de humo Gloria
- Detector de humo System Sensor
- Detector de humo Inovonics
- Detector de humo Pyrexx
- Detector de humo Pristine
- Detector de humo Cavius
- Detector de humo WisuAlarm
- Detector de humo Cordes
- Detector de humo Deltronic
- Detector de humo Insafe
- Detector de humo Gewiss
- Detector de humo No-Flame
- Detector de humo Egardia
- Detector de humo GEV
- Detector de humo Frient
- Detector de humo Qolsys
- Detector de humo SAVS
Últimos Detector de humo Manuales
18 Octubre 2024
16 Octubre 2024
16 Octubre 2024
16 Octubre 2024
9 Octubre 2024
8 Octubre 2024
8 Octubre 2024
3 Octubre 2024
3 Octubre 2024
2 Octubre 2024