Focal FDP 6.900 Manual de Usario

Focal receptor FDP 6.900

Lee a continuación 📖 el manual en español para Focal FDP 6.900 (8 páginas) en la categoría receptor. Esta guía fue útil para 9 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/8
1
POWER PER CHANNEL:
6 X 150 wRMS @ 4 ohms at less than 1% THD
4 x 200 wRMS @ 2ohms + 2 x 250 wRMS
4 x 150 wRMS @ 4ohms + 1 x 500 wRMS (Ch 5+6, Bridged @ 4ohms)
4 x 150 wRMS @ 4ohms + 1 x 600 wRMS (Ch 5+6, Bridged @ 2ohms)
INPUTS SWITCH
2 = Use input 1+2 and route them to channels 3+4 and 5+6
4 = Use input 1+2 and 3+4
1+2 and 3+4 are attenuated by -6dB and routed to 5+6.
This al ws constant bass loudness when you fade between 1+2 and 3+4.lo
6 = Use all six inputs.
CHANNELS 1 & 2 CROSSOVER CONFIGURATION
Flat: Full Range Signal. No crossover activated.
HP: Activates the High Pass Filter for a midbass or tweeter.
Copy 3 & 4: Copies the signals and filters from channels 3 & 4 to channels 1 & 2. Use this mode when you need
a band pass filter on all four channels. Recommended when bridging channels 1, 2, 3, 4.
CHANNELS 3 & 4 CROSSOVER CONFIGURATION
Flat: Full Range Signal. No crossover activated.
HP: Activates the High Pass filter.
LP/BP: Activates the selection of either a Low Pass filter for woofer or a Band Pass filter for midrange.
CHANNELS 5 & 6 CROSSOVER CONFIGURATION
Flat: Full Range Signal. No crossover activated.
HP: Activates the High Pass filter.
LP/BP: Activates the selection of either a Low Pass filter for woofer or a Band Pass filter for midrange.
Sub Mode: Inputs 5+6 are mixed to mono for bridge mono operation. Cross er slopes become 24dB. ov
The subwoofer remote volume control is activated. There is a clip distortion light on the remote volume control.
If you see this light is on, reduce volume until the light goes out so that you do not damage your speaker.
FDP 6.900 : SIX CHANNEL AMPLIFIER
Operation / Configuration
2
AUTOMATIC POWER TURN ON/OFF
1. The best way to automatically turn the amplifier power on and off is to use the REM wire from your source radio
connected to the REM amplifier terminal.
2. If your original equipment stereo or source radio has a BTL amplifier then the RCA inputs have an auto turn
on sensing circuit. When you connect the high level BTL speaker wires to the RCA input the REM wire is not
necessary.
RCA INPUT, BOTH LOW LEVEL AND HIGH LEVEL.
The amplifier control has sufficient adjustment range for both low level and high level input into the RCA LEVEL
jacks. A factory source radio that does not have RCA output, using the wires that are connected to the speakers,
can be directly connected to the RCA jacks when the amplifier control is adjusted to 8V.LEVEL
SETTING LEVEL
Set the amplifier control to minimum before you turn on the amplifier for the first time.LEVEL
For lowest distortion and lowest noise the amplifier should be set at the lowest setting that yields LEVEL
sufficient loudness without distortion. For lowest noise your source radio volume control should be near
maximum that does not cause distortion.
find the best amplifier setting: To LEVEL
With the amplifier at minimum, slowly increase the source radio volume around 3/4 without distortion. LEVEL to
Then, slowly turn up the amplifier control the maximum desired loudness. Listen very carefully and LEVEL to
turn down the amplifier control if you hear any distortion. LEVEL
SETTING SUBWOOFER HIGH PASS SUBSONIC FILTER
A subwoofer should have a high pass filter often called a subsonic filter. The purpose of a subsonic filter is to
limit very low frequencies that your subwoofer can not play loud enough without damage. Removing subsonic
frequencies can allow your subwoofer to play louder.
For a sealed box, the high pass is typically set between 10Hz and 30Hz to increase power handling capacity.
For a vented box, the high pass filter must be set 5Hz lower than the port tune frequency to prevent woofer
damage.
FPD 900.6 CONFIGURATION EXAMPLES
6 CHANNEL STEREO NON-BRIDGED
(SEE GRAPHIC C1)
If you have two input wires from the source deck plug them into inputs 1+2.
Set INPUT switch to 2.
If you have four input wires from the source deck plug them into inputs 1+2 and 3+4.
Set INPUT switch to 4.
If you have five input wires from the source deck plug them into inputs 1+2 and 3+4. The subwoofer plugs into
channel 5. Set channel 5+6 MODE switch to SUB.
Set INPUT switch to 6.
If you have six input wires from the source deck plug them into inputs 1+2, 3+4, 5+6.
3
Set INPUT switch to 6.
If you are NOT using a subwoofer set all switches to flat. If you hear distortion in your woofers set all switch to
HP and adjust all HP frequency until the distortion goes away. This will probably be around 50 Hz to 70 Hz.
50Hz6 FLAT or HP
50Hz FLAT or HP
50Hz FLAT or HP
C1
RADIO
XOVER
XOVER XOVERXOVER
XOVER XOVER
<GRAPHIC of Source Radio to input channel 1+2, 3+4, 5+6 of amplifier. Woofer/Tweeter/Xover on channels 1+2, 3+4, 5+6>
If you are using two subwoofers: (SEE GRAPHIC C2)
Put your woofer/tweeters on channel 1+2, 3+4.
Set 1+2, 3+4 switch to HP.
Adjust 1+2, 3+4 HP frequency to 50 Hz.
Subwoofers on channel 5+6.
Set channel 5+6 switch to LP/BP.
Set channel 5+6 MODE switch to SUB.
Plug in the remote sub control.
Adjust the 5+6 LP frequency to 50 Hz.
For a sealed box adjust the 5+6 HP frequency to 10 Hz.
For a vented box adjust the 5+6 HP frequency 5 Hz lower than the port tune frequency.
REMOTE SUB CONTROL
+ –
SUBWOOFER
+ –
SUBWOOFER
50Hz6 HP
50Hz20Hz SUB LP/BP
50Hz HP
C2
RADIO
XOVER
XOVER
XOVER XOVER
C2 <GRAPHIC of Source Radio to input channel 1+2, 3+4, 5 of amplifier. Woofer/Tweeter/Xover on channels 1+2, 3+4, one
subwoofer wired to channel 5 one subwoofer wired to channel 6>

Especificaciones del producto

Marca: Focal
Categoría: receptor
Modelo: FDP 6.900
Colocación del dispositivo: Ingebouwd
Tipo de operación: Draaiknop
Color del producto: Black, Stainless steel
Pantalla incorporada: Nee
Ancho: 360 mm
Profundidad: 510 mm
Altura: 70 mm
Bloqueo infantil: Ja
Peso del embalaje: 8100 g
Ancho del embalaje: 440 mm
Empaquetadura en profundidad: 580 mm
Altura del embalaje: 185 mm
Tipo de material (arriba): Glas/roestvrij staal
Potencia quemador/zona de cocción 2: 1400 W
Potencia quemador/zona de cocción 1: 2300 W
Número de quemadores/zonas de cocción: 2 zone(s)
tipo de placa: Inductiekookplaat zones
Quemador/zona de cocción tipo 1: Groot
Quemador/zona de cocción tipo 2: Regulier
Número de quemadores de gas: 0 zone(s)
Número de zonas de cocción electrónicas: 2 zone(s)
Posición de control: Boven voorzijde
Carga conectada (eléctrica): 3700 W
Ancho del compartimento de instalación: 340 mm
Profundidad del compartimento de instalación: 490 mm
Altura del compartimento de instalación: 64 mm
Carga conectada (gas): - W
Indicador de calor residual: Ja
reconocimiento panorámico: Ja
Fuente de alimentación quemador/zona de cocción 1: Electrisch
Fuente de alimentación quemador/zona de cocción 2: Electrisch
Posición del quemador/zona de cocción 1: Midden achter
Diámetro quemador/zona de cocción 1: 220 mm
Posición quemador/zona de cocción 2: Midden voor
Quemador/zona de cocción diámetro 2: 180 mm
Forma zona de cocción 1: Rechthoekig
Forma zona de cocción 2: Rechthoekig

¿Necesitas ayuda?

Si necesitas ayuda con Focal FDP 6.900 haz una pregunta a continuación y otros usuarios te responderán




receptor Focal Manuales

receptor Manuales

Últimos receptor Manuales