Frigicoll PCO-Kit Manual de Usario
Frigicoll
Varios controles climáticos
PCO-Kit
Lee a continuación 📖 el manual en español para Frigicoll PCO-Kit (6 páginas) en la categoría Varios controles climáticos. Esta guía fue útil para 2 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/6
![](https://manualstech.ams3.cdn.digitaloceanspaces.com/html/nl/frigicoll/pco-kit/html/bg1.png)
Owner's Manual
PCO-Kit
MDL-PSM10W
MDL-PSM18W
MDL-PSM28W
Please read this manual carefully before use and keep it properly.
![](https://manualstech.ams3.cdn.digitaloceanspaces.com/html/nl/frigicoll/pco-kit/html/bg2.png)
Content
Package BOM...................................................................................................1
Overview...........................................................................................................2
Safety Precautions ..........................................................................................2
Main Components Name & Function .............................................................3
Instructions For Use ........................................................................................4
Installation Method .......................................................................................... 5
Replace UV-C Tube .......................................................................................... 6
Environmental Protection And Safety ........................................................... 7
Fault Rectication ...........................................................................................7
Warranty Service .............................................................................................8
Package BOM
1
2
5
4
3
68
7
Screw Hole
Screw Hole
Screw Hole Screw Hole
Cut Size: Ø75mm
User Manual
PCO-kit
No. Name Number
①Control Box 1pcs
②Protection Net 1pcs
③UV-Tube 1pcs
④Cutting Hole Card 1pcs
⑤User manul 1pcs
⑥M4 Screw 5pcs
⑦Accessory Port 1pcs
⑧Transparent Plastic Ziplock Bag 1pcs
Note: ⑤ ⑥ ⑦ Pack in ⑧.
1
![](https://manualstech.ams3.cdn.digitaloceanspaces.com/html/nl/frigicoll/pco-kit/html/bg3.png)
Overview
Basic feature: IP20
Suitable for air-conditioning duct.
Technical Parameters:
Model MDL-PSM10W MDL-PSM18W MDL-PSM28W
Power(W) 10 18 28
AC Source 220-240V~ 50/60Hz
Rated Current (A) 0.05 0.095 0.16
Product Size
L*W*(h1+h2)(mm) 250*157*(72+227) 250*157*(72+371) 250*157*(72+565)
Airow(m3/h) <1500 <2600 <4300
Safety Precautions
To prevent accidents such as damage, fall, electric shock and re, which may
cause personal injury, please install and use the PCO-kit in strict accordance with
the instructions.The PCO-kit is not replaceable by the user. Do not alter the UV-C
tube or replace the components!
The power supply must be within the rated voltage.
(If the PCO-kit works at voltages outside of range for a long time, it may be
damaged.)
Ask a specialized technician to check or repair the PCO-kit.
(Operations performed by a non-professional staff may cause danger.)
In case of exception, cut off the power supply immediately and contact the sales
store.(Provide the model for maintenance. Refer to the label attached to the
control box.)
The external exible cable or cord of this device are not replaceable. The PCO-
kit would be discarded if exible cable or cord are damaged.
When installing PCO-kit, it should not be too close to the air outlet.
(Too close to the air outlet, the ultraviolet rays of the PCO-kit may cause harm
to people, animals or plants.)
UV-C tubes are hazardous materials, do not discard them at will; please handle
them according to the recycling management of hazardous materials.
Do not look directly at the pco-kit when the UV-C lamp is working.
The pco-kit installation position is more than 1.5 meters away from the air outlet.
The cable between the signal port and the controller should not exceed 3 meters.
Fibre-duct need metal support (from local market) inside duct and reserve
inspection hole on duct bottom.
2
Main Components Name
Main Components Function
1
2
3
4
1
23
4
5
① Power Swicth Key
② Digital Tube
③ Set Button
④ Signal Line Port
(Alarm Port &Control Port)
⑤ Power Cable
1. Digital tube display:
(1) Display “U1” or “U2”, U1 mode is a stand-alone mode,U2 mode is a multi
-machine mode.When the PCO-kit is powered on, or when the "Set" key is
pressed, U1 or U2 are displayed.
(2) When the PCO-kit works normally, the life of the UV lamp is displayed.
(3) Error code display. When the PCO-kit fails, the fault code and life time will be
displayed in turns at 3S intervals.
2. Set button:
1) Switch working modes U1 and U2.
2) When the service life of the UVC-tube ends, long press(about 5s) this button to
reset to the default value of 8000 hours.
3. Alarm port (1,2): PCO-kit outputs an abnormal output signal to the control panel
to remind the user that the product is abnormal.
4. Control port ( 3, 4): The user can control the "running" and "stop" states of
PCO-kit on the control panel interface. When the PCO-kit is turned on, it will
start to work after 5s, if the air duct is windy; when there is no wind in the air
duct, the PCO-kit will not work.
Fault Code Description
Wind sensor failure.
UV-C tube is not bright or the photoresistor is damaged.
There is light detected when the UV-C tube is not turned on.
The photoresistor is damaged or the structure has light leakage.
Ballast failure.
End of life of UV-C tube.
3
Especificaciones del producto
Marca: | Frigicoll |
Categoría: | Varios controles climáticos |
Modelo: | PCO-Kit |
¿Necesitas ayuda?
Si necesitas ayuda con Frigicoll PCO-Kit haz una pregunta a continuación y otros usuarios te responderán
Varios controles climáticos Frigicoll Manuales
![Frigicoll](/images/pdf_free.png)
29 Agosto 2024
![Frigicoll](/images/pdf_free.png)
26 Agosto 2024
Varios controles climáticos Manuales
- Varios controles climáticos Bosch
- Varios controles climáticos AEG
- Varios controles climáticos Honeywell
- Varios controles climáticos Inventum
- Varios controles climáticos Junkers
- Varios controles climáticos Nefit
- Varios controles climáticos Siemens
- Varios controles climáticos Vaillant
- Varios controles climáticos A.O. Smith
- Varios controles climáticos Argo
- Varios controles climáticos Edimax
- Varios controles climáticos Eurom
- Varios controles climáticos Elektrobock
- Varios controles climáticos Stiebel Eltron
- Varios controles climáticos Buderus
- Varios controles climáticos Elco
- Varios controles climáticos Dimplex
- Varios controles climáticos Easymaxx
- Varios controles climáticos Trotec
- Varios controles climáticos SMA
- Varios controles climáticos Danfoss
- Varios controles climáticos AWB
- Varios controles climáticos Xavax
- Varios controles climáticos Gira
- Varios controles climáticos Vasco
- Varios controles climáticos Sonnenkonig
- Varios controles climáticos REMKO
- Varios controles climáticos Brink
- Varios controles climáticos Sungevity
- Varios controles climáticos Oregon Scientific
- Varios controles climáticos Muller
- Varios controles climáticos VC Trade
- Varios controles climáticos Riello
- Varios controles climáticos MCZ
- Varios controles climáticos Ygnis
- Varios controles climáticos Kaysun
- Varios controles climáticos Nuon
- Varios controles climáticos Renusol
- Varios controles climáticos Progenion
- Varios controles climáticos Technea
- Varios controles climáticos Plugwise
- Varios controles climáticos HRSolar
- Varios controles climáticos DGFlow
- Varios controles climáticos Premix
Últimos Varios controles climáticos Manuales
![Eurom](/images/pdf_free.png)
20 Octubre 2024
![AEG](/images/pdf_free.png)
20 Octubre 2024
![Elco](/images/pdf_free.png)
5 Octubre 2024
![Junkers](/images/pdf_free.png)
20 Septiembre 2024
![Junkers](/images/pdf_free.png)
19 Septiembre 2024
![Elco](/images/pdf_free.png)
17 Septiembre 2024
![Ygnis](/images/pdf_free.png)
Ygnis TOTALECO TURBO Diversen klimaatbeheersing Manual de Usario
14 Septiembre 2024![Oregon Scientific](/images/pdf_free.png)
8 Septiembre 2024
![Riello](/images/pdf_free.png)
8 Septiembre 2024
![Premix](/images/pdf_free.png)
8 Septiembre 2024