Furman CN-3600SE Manual de Usario

Lee a continuación 📖 el manual en español para Furman CN-3600SE (14 páginas) en la categoría No categorizado. Esta guía fue útil para 7 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/14
DIN-00021-A ENGLISH 11-12
CN-3600SE
Instruction Manual
CN-3600SE
For additional information refer to the Quick Start
Guide, included with product packaging.
www.furmancontractor.com
16 A Maximum
For more information call:
Para más información llame al:
Pour plus de renseignements:
877-486-4738
CONTRACTOR SERIES SmartSequencer
PRIMARY L INK
SECONDARY LINK
ETHERNET
DELAY 1
DELAY 2
DELAY 3
POWER
PROTECTION OK
EXTREME VOLTAGE
ON
OFF
REMOT E
16 A MPS
PUSH TO RESET
UNSW ITC HED ~ 220V-240V, 50/60H z
MAX LOAD 10A , 2300 WATT S
SEQUENCE
AV equipment is most vulnerable and susceptible
to damage during those first few milliseconds after
the power is turned on or off.
When audio amplifiers are powered, a large inrush
current occurs as the large capacitors in the power
supply charge. This inrush can be on the order of
several hundred amps for a number of AC cycles.
If more than one amplifier is connected to a single
branch circuit, the inrush current is multiplied and
can cause the circuit breaker to trip, or the line volt-
age to sag. Additionally, if the amplifier is powered
either before or concurrent with signal processing
equipment, the result can be a dreaded speaker
“pop”. This all-too familiar noise occurs as tran-
sients from the signal processing equipment ow
uncontrolled to the inputs of the power amplifier.
The amplifier amplifies this signal and passes the
transient “pop” along to the speakers. The result
can be catastrophic to both speaker and amplifier.
Powering down A/V is equally as perilous. Unlike
other A/V equipment, the large capacitors found
in amplifiers will store their charge. This means
if signal processing devices and amplifiers are
switched off simultaneously, the amplifiers are still
operational as the signal processing equipment is
switched off. Just as with startup, the power down
phase can cause equipment to emit transients
which are amplified by the amplifier, then propa-
gated to the speakers and “pop”!
AC Power sequencing addresses these problems
by powering up your equipment in stages. The
signal processing equipment is powered up first
and allowed to stabilize, and then the amplifiers
are powered up. The rst stage signal processing
equipment may still emit transient noise upon pow-
er up, but because the amplifiers have yet to power
on, the transient signal passes without incident.
Power sequencing stages the activation of heavy
loads, which prevents nuisance breaker trips and
equipment damage due to line sags and brown-
outs. This means that inrush currents are offset
in time, rather than occurring simultaneously. This
can also be advantageous to upstream equipment
if the sequencer is supplementing other power
management such as a UPS or voltage regulator.
The Furman Contractor CN-3600SE provides three
delay stages. Each stage is independently fused
and protected. If three stages of power sequencing
are not enough for your application, you can chain
together multiple (up to 99) sequencers using Fur-
man’s exclusive SmartSequencing™ technology
for up to 297 independent stages! Please review
the reference materials for CN-3600SE thoroughly,
for a clear understanding of SmartSequencing
1
The box should contain the following items:
1) Contractor Series Quick Start Guide
2) Pair of Security Keys
3) Two removable Cover Shields and four screws
4) Three Phoenix –Type Connectors
Pair of Security Keys Two Removable Cover Shields and Four Screws 3 Phoenix Type Connectors
(2 four pin, 1 five pin)
At Furman Sound, we have spent the last 30 years
quietly obsessing about AC Power Quality and how
best to protect your professional equipment from
the noise and hazards of AC power. Over the years
we have developed a multitude of technologies
that have spared countless devices from damage
and earned the trust and respect of the Profes-
sional A/V industry. This manual will explain some
of the Furman technologies that have been incor-
porated into the design of the CN-3600SE. If you
are already a Furman customer you are probably
already familiar with our portfolio of protective
technologies. If this is your first Furman Contractor
purchase, we appreciate your business. We have
spared no expense in making sure that your CN-
3600SE will perform admirably. Welcome Aboard!
Before You Begin Inspect Upon Receipt
Why choose Furman?
Why choose AC power sequencing?
CN-3600SE
Introduction
Congratulations and thank you for choosing the
Furman CN-3600SE. We assure you that your
sequencer will provide many years of trouble
free operation. The CN-3600SE is a 230VAC 16
Amp Contractor Grade Surge Protector and Power
Sequencer equipped with Furman’s exclusive
SmartSequencing™ technology. SmartSequenc-
ing™ defines a whole new level of power manage-
ment and control while streamlining installations
from start to finish.
www.furmancontractor.com 877-486-4738 2
Table of Contents
Technologies..................................................................................................................................................................................................................2
Front and Back Panel Features.......................................................................................................................................................................................3
Security and Safety........................................................................................................................................................................................................4
SmartSequencing™101.............................................................................................................................................................................................4, 5
DIP Switch Settings................................................................................................................................................................................................5, 6, 7
SmartSequencing Link Status Lights..............................................................................................................................................................................7
Indicator Lights..............................................................................................................................................................................................................8
Circuit Breakers.............................................................................................................................................................................................................8
Rear Panel Terminal Barrier Strips............................................................................................................................................................................9, 10
CN-3600SE System Setup............................................................................................................................................................................................10
Example Setup Diagrams.............................................................................................................................................................................................11
Trouble Shooting Guide.................................................................................................................................................................................................12
Specifications...............................................................................................................................................................................................................13
Warranty Information....................................................................................................................................................................................................13
Technologies
BB-RS232
Remote Access (and BlueBOLT®) The CN-
3600SE is a member of Furman’s Contractor
series of devices. All members of the Contractor
series can be controlled remotely using an inte-
gral data-link and command API. The remote ac-
cess feature allows for integration with various
control systems. In addition to remote control,
API queries provide situational awareness and
local power quality data.
Furman’s optional BlueBOLT® RS-232-to- Eth-
ernet adaptor (shown above) provides additional
control programming and monitoring from any
Web-enabled device via Telnet, direct HTTP con-
nection, or www.mybluebolt.com
Linear Filtering Technology
Linear Filtering Technology (LiFT) uses a nely
tuned low-pass filter to reduce differential AC
noise. LiFT is remarkable in its ability to linearly
filter AC noise such that the attenuation curve is
continuous over a wide bandwidth.
SMP Protection
Furman’s exclusive Series Multistage Protection
(SMP) Technology prevents equipment down-
time by monitoring and quickly reacting to ex-
treme line voltage conditions. SMP protection
is designed to withstand voltages of 6000 Volts
and 3000 Amps without sustaining damage. As
the name implies, there are multiple stages of
protection which are designed to shield con-
nected equipment from line hazards.
SmartSequencing™
Furman SmartSequencing is a communica-
tion technology that allows Furman contractor
devices to be linked together and controlled up
to distances of 300 Meters (about 1000 feet).
SmartSequencing devices can be chained to-
gether to form a network of sequencers. A maxi-
mum of 99 SmartSequencers can be linked to-
gether to form a SmartSequencing network that
spans a distance of 30 KM (18.2 Miles)!
SmartSequencing devices can be connected to-
gether without regard for polarity, wire type, and
environmental noise. It is an extremely forgiv-
ing technology. Although we recommend solid
twisted pair for best results, virtually any wire
size and type can be used over short distances
without concern for signal degradation.
SERIE S M ULTI -ST AGE
PROTECTION
SMP
LI NEAR FILTERING
TECHNOLOGY
Extreme Voltage Shutdown
Furman’s trusted (EVS) over-voltage detection
protects against prolonged over-voltage con-
ditions, such as accidental connection to high
voltage or an intermittent loss of neutral. It does
so by continuously monitoring the incoming AC
voltage. When an unsafe condition is detected,
a relay shuts off the power to the outlets until
the EVS condition has subsided. The CN-3600SE
also allows the user to define how the unit will
recover from an EVS shut-down. The Extreme
Voltage Shutdown technology is a tremendous
asset.
EVS
EXTREME VOLTAGE
S H U T D O W N
Optional BlueBolt to RS232 adapter

Especificaciones del producto

Marca: Furman
Categoría: No categorizado
Modelo: CN-3600SE

¿Necesitas ayuda?

Si necesitas ayuda con Furman CN-3600SE haz una pregunta a continuación y otros usuarios te responderán




No categorizado Furman Manuales

No categorizado Manuales

Últimos No categorizado Manuales