Gardena Comfort 4000/5 Manual de Usario

Gardena bomba de agua Comfort 4000/5

Lee a continuación 📖 el manual en español para Gardena Comfort 4000/5 (19 páginas) en la categoría bomba de agua. Esta guía fue útil para 7 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/19
6000/6 inox Art. 17365000/5 Art. 17344000/5 Art. 1732
D Betriebsanleitung
Gartenpumpe
GB Operating Instructions
Garden Pump
F Mode d’emploi
Pompe de surface pour arrosage
NL Gebruiksaanwijzing
Besproeiingspomp
S Bruksanvisning
Bevattningspump
DK Brugsanvisning
Trykpumpe
FI Käyttöohje
Puutarhapumppu
N Bruksanvisning
Hagepumpe
I Istruzioni per l’uso
Pompa da giardino
E Instrucciones de empleo
Bomba para jardín
P Manual de instruções
Bomba de Jardim
PL Instrukcja obsługi
Pompa ogrodowa
H Használati utasítás
Kerti szivattyú
CZ Návod k obsluze
Zahradní čerpadlo
SK Návod na obsluhu
hradné čerpadlo
GR  
 
RUS Инструкция по эксплуатации
Садовый насос
SLO Navodilo za uporabo
Vrtna črpalka
HR Upute za uporabu
Vrtna pumpa
SRB Uputstvo za rad
BIH Baštenska pumpa
UA Інструкція з експлуатації
Садові насоси
RO Instrucţiuni de utilizare
Pompă de grădină
TR Kullanma Kılavuzu
Bahçe pompası
BG Инструкция за експлоатация
Градинска помпа
AL Manual përdorimi
Pompë kopshti
EST Kasutusjuhend
Aiapump
LT Eksploatavimo instrukcija
Sodo siurblys
LV Lietošanas instrukcija
Dārza sūknis
LV LT AL BG TR RO UAEST SRB
BIH HR SLO
RUS
GR SK CZ H PL P E I N FI DK S NL F GB D
GARDENA Garden Pump
4000/5 / 5000/5 / 6000/6 inox
Translation of the original German operating instructions.
Please read the operating instructions carefully and observe the
notes given. Use these operating instructions to familiarise your-
self with the product, the proper use and the safety instructions.
For safety reasons, children and young people under the age
of 16, as well as people not familiar with these operating
instructions, may not use this product. Persons with reduced
physical or mental abilities may use the product only if they are
supervised or instructed by a responsible person.
v Keep these operating instructions in a safe place.
Contents: 1. Area of application of your GARDENA Garden Pump . . . . . .12
2. Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
3. Initial Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
4. Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
5. Putting into Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
6. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
7. Trouble-Shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
8. Available accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
9. Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
10. Service / Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
1. Area of application of your GARDENA Garden Pump
Purpose: The GARDENA Garden Pump is designed for domestic use around
the house and garden.
When the pump is used for pressure boosting, the maximum
permissible internal pressure of 6 bar (on the delivery side)
must not be exceeded. The increased delivery pressure and the
pump pressure have to be added together.
Example: Pressure at the tap = 1.5 bar, maximum pressure of
the Garden Pump 4000/5 = 4.5 bar bar, total pressure = 6.0 bar.
Liquids that can be pumped: The GARDENA Garden Pump can be used for pumping
ground water and rain water, tap water and swimming pool
water containing chlorine.
Please note: The GARDENA Garden Pump is not suitable for continuous
operation (e.g. industrial applications, continuous circulat-
ingoperation). Corrosive, easily combustible, aggressive or
explosive liquids (such as gasoline, petroleum or nitro
thinner), saltwater and food must not be pumped.
The temperature of the liquid must not exceed 35 °C.
2. Safety Instructions
DANGER! Electric shock!
Risk of injury due to electric shock.
v Always unplug your Garden Pump before fil-
ling, after operation, when trouble-shooting
and before carrying out any maintenance work.
RISK OF INJURY!
Hot water – risk of scalding!
For pump 4000/5 only: If the pump is operated
for prolonged periods of time (> 5 min) with
the delivery side closed, the water in the pump
may heat up so that there is a risk of scalding
yourself with hot water.
v The pump should not run against the closed
delivery side for more than 5 minutes.
If the water supply on the intake side of the
pump fails, the water in the pump can heat up
so that if water emerges, injuries could be
caused by the hot water.
v Disconnect the pump from the mains via
the main circuit breaker, let the water cool
and secure the suction-side water supply
before putting into operation again.
Location
Caution: Pursuant to DIN VDE 0100-702 and
0100-738, AS/NZS 3000 use of the pump nearby
swimming pools and garden ponds and other
similar places is only permissible if the pump is
operated via a residual-current device (FI switch)
with a residual current rating of ≤ 30 mA.
The pump must not be operated when there are
persons in the swimming pool or garden pond.
The pump must be located on solid, even ground,
protected from flooding. Take care that the pump
cannot fall into water. Position the pump at a safe
distance (min. 2 m) from the liquid to be pumped.
As an additional safety device an authorised safety
switch can be used.
v Please ask your electrician for his advice.
When connecting the pump to the water supply
system, the country-specific sanitary regulations
must be observed to prevent water not of drin-
king water quality being drawn back in.
v Please consult a specialist for sanitary
installations.
Extension cables
Date indicated on the type plate must match
technical data of the mains supply.
Only use extension cables authorised in
accordance with HD 516.
v Consult your qualified electrician.
v Don’t use the power cable for carrying the
pump or for plugging off.
In Austria
In Austria, the electrical connections must be
made according to ÖVE-EM 42, T2 (2000) /
1979 §22 based on § 2022. Pursuant to this
regulation it’s imperative to operate pumps for
swimming pools and garden ponds exclusively
via an isolating transformer.
v Please ask your electrician.
In Switzerland
In Switzerland mobile appliances which are
used outdoors, must be connected via a residual-
current device.
Visual check
v Before operating the pump, first make a visual
cheek, if there is any damage of the pump
(esp. regarding power cable and plug).
A damaged pump must not be used.
v In case of damage, please have the pump
checked by our GARDENA Service Centre or
by an authorised electrician.
v A damaged connection cable may only
be exchanged by GARDENA Service or an
authorised electrician.
Note
v Protect the pump from rain. Don’t use the
pump in wet or moist area.
In order to avoid dry-running of the pump, take
care that the end of the suction hose is always
submerged into the liquid.
v Before each operation, fill the pump to over-
flowing with approx. 2 to 3 l of the liquid to be
pumped!
Sand and other abrasive substances in the liquid
cause in-creased wear and reduce the pump’s
output.
Pumping dirty water, e.g. stones, pine needles
etc., can cause damage to the pump.
v Do not pump dirty water.
The minimum flow rate is: 4000/5: 90 l/h
(= 1.5 l/min); 5000/5: 200 l/h (= 3.3 l/min).
Watering accessories with lower rate must not
be operated.
12
GB
13
GB

Especificaciones del producto

Marca: Gardena
Categoría: bomba de agua
Modelo: Comfort 4000/5
Ancho: 203 mm
Profundidad: 234 mm
red LAN: Ja
Cables suministrados: SATA
Número de puertos USB 2.0: 4
Número de puertos HDMI: 1
Micrófono, entrada de línea: Ja
Número de puertos Ethernet LAN (RJ-45): 1
Salidas de auriculares: 1
Soporta Windows: Windows 10 x64, Windows 11 x64
Número de puertos USB 3.2 Gen 1 (3.1 Gen 1) Tipo A: 2
Zócalo del procesador: LGA 1700
Fabricante del procesador: Intel
Memoria interna máxima: 64 GB
Canales de salida de audio: 7.1 kanalen
Tipo de interfaz Ethernet: Gigabit Ethernet
Entrada de línea: Ja
placa base con chipset: Intel H610
Tipo de ranura de memoria: DIMM
Canal de memoria: Dubbelkanaals
Ranuras PCI Express x1 (Gen 3.x): 1
Número máximo de HDD por gabinete: 3
Interfaces de unidad de almacenamiento compatibles: SATA III
Puerto(s) PS/2: 1
Componente para: PC
Número de conectores SATA III: 3
No ECC: Ja
Procesadores compatibles: Intel Celeron, Intel Core i3, Intel Core i5, Intel Core i7, Intel Core i9, Intel Pentium Gold
Tipos de memoria soportados: DDR4-SDRAM
Wifi.: Nee
Tipos de unidades de almacenamiento compatibles: HDD
Familia de chipsets de placa base: Intel
Factor de forma de la placa base: micro ATX
Número de ranuras de memoria: 2
Velocidades de reloj de memoria admitidas: 2133,2400,2666,2800,2933,3200 MHz
tipo de BIOS: UEFI AMI
Tamaño de la memoria del BIOS: 128 Mbit
Soporte para procesamiento paralelo: Niet ondersteund
Conexión para refrigerador de CPU: Ja
Conexiones para ventiladores de caja: 1
Conector de alimentación ATX (24 pines): Ja
Conector del panel frontal: Ja
Conexiones USB 2.0: 1
Conexión para panel de audio en el frente: Ja
Memoria sin búfer: Ja
Conexiones USB 3.2 Gen 1 (3.1 Gen 1): 1
Borrar perilla CMOS: Ja
Zócalos de procesador compatibles: LGA 1700
conector de alimentación de 12V: Ja
Ranuras PCI Express x16 (Gen 4.x): 1
Conector de audio: Ja

¿Necesitas ayuda?

Si necesitas ayuda con Gardena Comfort 4000/5 haz una pregunta a continuación y otros usuarios te responderán




bomba de agua Gardena Manuales

bomba de agua Manuales

Últimos bomba de agua Manuales