Generac RG04854ANAC Manual de Usario

Generac No categorizado RG04854ANAC

Lee a continuación 📖 el manual en español para Generac RG04854ANAC (56 páginas) en la categoría No categorizado. Esta guía fue útil para 4 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/56
(000209b)
WARNING
Loss of life. This product is not intended to
be used in a critical life support application.
Failure to adhere to this warning could result
in death or serious injury.
Owners Manual
Spark-Ignited Stationary Generators
Residential and Commercial
22 kW 2.4L
25 kW 1.5L
27 kW 2.4L
30 kW 1.5L
32 kW 2.4L
36 kW 2.4L
38 kW 2.4L
45 kW 2.4L
48 kW 5.4L
60 kW 2.4L
Register your Generac product at:
WWW.GENERAC.COM
1-888-GENERAC
(888-436-3722)
Para español , visita: http://www.generac.com/service-support/product-support-lookup
Pour le français, visiter : http://www.generac.com/service-support/product-support-lookup
SAVE THIS MANUAL FOR FUTURE REFERENCE
®
ii tationary GeneratorsOwner’s Manual for S
Use this page to record important information about
the generator set.
For quick and easy reference, copy the information
printed on the Unit Identification Label onto the sample
label printed here. The Unit Identification Label is located
on the base frame adjacent to the front engine mount on
all models.
When contacting an Independent Authorized Service
Dealer (IASD) about parts and/or service, always provide
the complete model number and serial number.
Operation and Maintenance: Proper maintenance and
care of the generator ensures safe operation and longer
service life while also keeping operating expenses to a
minimum. It is the operator’s responsibility to perform all
safety checks, to make sure that all maintenance is
performed promptly, and to have the equipment checked
periodically by an Independent Authorized Service
Dealer.
Normal maintenance, service and replacement of parts
are the responsibility of the owner/operator, and are not
considered defects in materials or workmanship within
the terms of the warranty. Individual operating habits and
usage may contribute to the need for additional
maintenance or service.
When the generator requires servicing or repairs, contact
an Independent Authorized Service Dealer for
assistance. Authorized service technicians are factory-
trained and are capable of handling all service needs.
When the generator requires servicing or repairs, the
manufacturer recommends contacting an Independent
Authorized Service Dealer for assistance. Authorized
service technicians are factory–trained and are capable
of handling all service needs.To locate the nearest
Independent Authorized Service Dealer, please visit the
dealer locator at:
www.honeywellgenerators.com/find-a-dealer
INDEPENDENT AUTHORIZED
SERVICE DEALER LOCATION
To locate the nearest
INDEPENDANT AUTHORIZED SERVICE
DEALER,
please call this number:
1-800-333-1322
or visit the dealer locator at:
www.generac.com/Service/DealerLocator/
GENERATOR UNIT
GEN MODEL:
MODEL:
SERIAL:
ALTERNATE
PROD DATE:
COUNTRY OF ORIGIN:
GENERATOR DATA
KW KVA HZ PF
UPSIZE ALT KW KVA
VOLT / AMP
ENG RPM ALT RPM
BREAKER KW AMP
X’D X”D
ROTOR STATOR CLASS
WINDINGS @ AMBIENT TEMP
MANUF.
LOC
003564
Figure 1-1. Sample Label
(000393a)
WARNING
CANCER AND REPRODUCTIVE HARM
www.P65Warnings.ca.gov.
Owner’s Manual for Stationary Generators iii
Section 1: Safety
Introduction ..........................................................1
Read This Manual Thoroughly ....................................1
Safety Rules .........................................................1
How to Obtain Service .........................................2
General Hazards ..................................................2
Exhaust Hazards ..................................................3
Fire Hazards .........................................................3
Electrical Hazards ................................................3
Explosion Hazards ...............................................3
Battery Hazards ...................................................4
Section 2: General Information
Emissions .............................................................5
Emissions Data Plate ..................................................5
Specifications ......................................................6
Engine Oil Recommendations ............................8
Weather and Maintenance Kits ...........................8
Coolant Water Treatment ....................................8
Fuel Requirements ..............................................8
Reconfiguring the Fuel System ..........................9
Fuel Conversion Procedure from NG to LPV ..............9
Change Fuel Selection ..............................................10
Battery Requirements .......................................10
Battery Charger .........................................................10
Battery Safety Precautions ........................................10
Corrosion Protection .........................................11
Section 3: Activation and Startup
Orientation ..........................................................13
Remove Side Access Panels ............................13
Install Battery .....................................................13
Open Viewing Window ......................................14
Activate Unit ......................................................15
Start and Run Engine ........................................16
Operational Checks ...........................................16
Self Test ....................................................................16
Check Manual Transfer Switch Operation .................17
Electrical Checks ....................................................... 17
Test Generator Under Load ......................................17
Test Auxiliary Shutdown Switch Operation ...............18
Check Automatic Operation ......................................18
Securing the Generator .................................... 19
Section 4: Operation
Control Panel ..................................................... 21
Auto/Manual/Off ................................................. 21
Menu Navigation ................................................ 22
Alarm/Warning Conditions ............................... 24
Change Time and Date ...................................... 24
Programmable Timers ...................................... 24
Dealer Programmable ...............................................24
User Programmable ..................................................24
USB Port for Firmware Updates ....................... 24
Battery Charger ................................................. 25
Transfer Switch Automatic Operation ............. 25
Automatic Sequence of Operation ............................25
Transfer Switch Manual Operation .................. 26
Transfer to Generator Power .....................................26
Transfer Back to Utility Power ...................................27
Section 5: Maintenance
Component Locations ...................................... 29
Access Panels ................................................... 30
Removal ....................................................................30
Installation .................................................................30
Maintenance ....................................................... 30
Service Maintenance Schedule .................................31
Remove From Service ....................................... 31
30 Hour Break-In ................................................ 32
Daily Maintenance ............................................. 32
Schedule A Maintenance .................................. 32
Schedule A Maintenance Item Locations ..................33
Preliminary Instructions ............................................. 33
Check Enclosure Louvers .........................................33
Check Fuel Lines .......................................................33
Check Coolant Level and Hoses ...............................33
Check Radiator for Clogging .....................................34
Table of Contents

Especificaciones del producto

Marca: Generac
Categoría: No categorizado
Modelo: RG04854ANAC

¿Necesitas ayuda?

Si necesitas ayuda con Generac RG04854ANAC haz una pregunta a continuación y otros usuarios te responderán




No categorizado Generac Manuales

No categorizado Manuales

Últimos No categorizado Manuales