Gerni Super 160.3 Manual de Usario

Lee a continuación 📖 el manual en español para Gerni Super 160.3 (15 páginas) en la categoría Limpiador de alta presión. Esta guía fue útil para 9 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/15
(03.2019)
Super 130.3
Super 135.3
Super 145.3 Works
Super 150.3
Super 160.3 Works
User Guide
2
The instruction consists of 4 parts. Part 1:3 Safety
Instructions. Part 2:3 User Guide. Part 3:3 Trouble-
shooting, Technical Data and Disposal. Part Warranty
Conditions.
Part 1:3 - Safety Instructions
Before rst use of the machine, read the
instructions carefully. Save instructions for
later use.
Safety instructions marked with this symbol
must be observed to prevent personal injury
or serious damage to property.
WARNING
This machine has been designed for use with
cleaning agents supplied or recommended by Ger-
ni. The use of other cleaning agents or chemicals
may adversely aect the safety of the machine.
High pressure jets can be dangerous if
subject to misuse. The jet must not be direct-
ed at persons, live electrical equipment or
the machine itself.
Do not use the machine within range of persons
unless they wear protective clothes.
Do not direct the jet against yourself or others in
order to clean footwear.
Risk of explosion Do not spray ammable liq-
uids.
High pressure washers shall not be used by chil-
dren or untrained personnel.
High pressure hoses, ttings and couplings are
important for the safety of the machine. Use only
hoses, ttings and couplings recommended by Ger-
ni.
To ensure machine safety, use only original spare
parts recommended by Gerni.
Water that has own through back-ow preven-
ters is considered to be non-potable.
Don’t use the machine if a supply cord or impor-
tant parts of the machine are damaged, e.g. safety
devices, high pressure hoses, trigger gun.
Inadequate extension cords can be dange rous.
If an extension cord is used, it shall be suitable for
outdoor use, and the connection has to be kept dry
and o the ground. It is recommended that this is
accomplished by a cord reel which keeps the sock-
et at least 60 mm above the ground.
Switch o and unplug the machine when leaving
it unattended, when nished using it or when con-
verting it to another function, when doing repair and
maintenance.
During use of high pressure washers, aerosols
may be formed. Inhalation of aerosols can be haz-
ardous to health, for the protection against aerosols
a respiratory mask of class FFP 2 or equivalent may
be needed, depending on the cleaning environment.
Intended Use and Terms of Liability
The Super-series have been developed for do-
mestic cleaning pur poses only and for use in an
upright position. Any other use is considered as
improper use.
A high pressure washer operates with dierent
levels of pressure and cleaning detergents for
various cleaning tasks and results. Always follow
instructions on detergents for use, emergency
and disposal.
Do not operate the machine at temperatures be-
low 0°C. Never start a frozen machine, never use
it indoor and never cover it during use. This is
considered improper and wrongful use. Use of
wrongful pressure, detergent and/or applications
may cause damage to machine, surfaces, material
and devices.
All of the above is considered improper and wrong-
ful use. Gerni accepts no liability for any damage
resulting from any improper or wrongful use.
Safety devices and their functioning
The machine automa tically stops when releasing
the trigger. The machine will start again when re-
activating the trigger. The spray handle features a
locking device. When activated, the spray handle
cannot be operated.
The machine has an automatic self-resetting thermal
protector. If the machine is overheated, the thermal
protector will cut the power supply. In this case, wait
for the machine to cool down. An integrated hydrau-
lic safety valve protects the system from excessive
pressure.
Precautions
The electric supply connection shall be made by a
qualied electrician and comply with IEC 60364-1.
It is recommended that the electric supply to this
machine should include either a residual current
device that will interrupt the supply if the leakage
current to earth exceeds 30 mA for 30 ms or a device
that will prove earth circuit.
Use motor start/delayed fuses with characteristic
C or D according to IEC/EN 60898-1 / IEC 947-2
or corresponding standards outside IEC.
3
If the supply cord is damaged, it must be replaced
by an authorized Gerni distributor or similar qualied
person in order to avoid a hazard.
No actions needed for adjusting machines marked
with dual voltage and frequency.
Supervise children not to play with the machine.
The operator and any one in the immediate vicinity
of the site for cleaning should take action to pro-
tect oneself from being struck by debris dislodged
during operation.
Always wear safety boots, respiratory mask, ear
protection, goggles and protective clothing during
operation.
The high pressure generated by the machine is a
particular source of danger. Hold the spray lance
rmly with both hands. The spray lance is aected
by a kickback force and a sudden torque during
operation.
See PART 3:3 for the actual size of the kickback
force.
During transportation: Position the machine hori-
zontally on the backside and secure with straps.
High pressure washers shall not be used nor main-
tained by children or untrained people or people with
reduced physical, sensory or mental capabilities
or lack of experience and knowledge.
Part 2:3 - User Guide
Provides a general overview of the machine and
operation elements along with illustrated sections on
preparation, operation, water connection, storage,
and user maintenance.
A Unpacking and preparing for use
Follow illustrations in A.
B Connection to potable water mains
High pressure washers are not suitable for con-
nection to the potable water mains. Always check
national regulations before connecting the machine
to potable water mains and use a back-ow preventer
if required.
Use ½" garden hose, 10-25 m.
Follow illustrations in B.
C Connection to other water sources
You can connect the machine to e.g. rain water ves-
sels, rivers, lakes and cisterns etc. and operate it in
suction mode. Follow illustrations in C.
D Pairing of spray handle and machine
Not relevant.
E
Leaving the machine unattended > 5 min.
See listed warnings. Follow the illustrations in E.
F After use and storage
After use always: Turn o the machine. Empty ma-
chine and accessories of water to avoid frost damage.
Remove the plug from socket. Disconnect water inlet
hose. Wind up electrical cable and high pressure
hose to avoid damage of cable, high pressure hose
and ttings. Storage of machine shall be frost free.
Follow illustrations in F.
G Maintenance, inspection and repair
Maintenance of the machine should always be done
when starting up after long time of storage.
Before use, always inspect the machine and
equipment for damages. In case of damages, act
according to listed warnings.
Do not attempt any maintenance not described
in the instructions. If the machine refuses to start,
stops, pulsates, pressure uctuates, motor buzzes,
fuse blows or no water comes out, check Part 3.3
Troubleshooting.
User maintenance according to illustrations in G.

Especificaciones del producto

Marca: Gerni
Categoría: Limpiador de alta presión
Modelo: Super 160.3

¿Necesitas ayuda?

Si necesitas ayuda con Gerni Super 160.3 haz una pregunta a continuación y otros usuarios te responderán




Limpiador de alta presión Gerni Manuales

Limpiador de alta presión Manuales

Últimos Limpiador de alta presión Manuales