1. Introducon
With the G.hn modem G4201TM you can easily extend
your network via exisng data and telephone cables.
The devices are also suitable for the distribuon of ber
opc connecons from the ONT to the router via exisng
telephone line.
The modem can use any type of cable - both twisted pair
and non-twisted pair - for data transmission and
achieves a speed of approx. 1500 Mbit/s (sum of both
transmission direcons).
The devices are always connected in pairs - a master and
a client. The master determines how fast the data is
transferred towards the client and back
(download/upload).
In networks with several clients, a G.hn switch can be
used instead of several master modems (see
Installaon). This enables the central administraon of
all G.hn components.
2. Package content
G420 M Master or G4201TM Client 1T
DC-12V/1A Power adapter
RJ11/RJ11 telephone cable , 4- wire (SISO and MIMO) 1.5m
TAE-F/RJ11 , 4- pole (SISO and MIMO) plug
3. Technical data
Dimensions: 111.5 * 83 * 24.5 mm
Weight: 0,19 kg
Operang temperature: 0°C - 40°C
Power consumpon: < 3 Wa
4. G.hn Specicaon
G.hn Wave2, 2-200 MHz
Connecon type: SISO (1 wire pair, 2-200MHz) and
MIMO (2 wire pairs, 2- MHz) 100
Total bandwidth ca. 1500 Mbit/s
(Total Download and Upload)
Spling of the bandwidth variable default: ,
70% Download (from master client) to
30% Upload (from client master) to
Maximum permissible aenuaon of the cable
connecon: 75dB
5. Interfaces
Panel and LED descripon
Labelling
Descripon
12V DC
Power input
RST
Recessed reset buon (15 Sec .)
LINE
G.hn port
GE
Gigabit Ethernet Port
PWR LED
Displays power availability
LINE LED
Status of the G.hn connecon
(Green - OK, Yellow - weak signal,
O - no connecon)
GE LED
Ethernet Connecon Status
6. Installaon
Variant 1 Point- -Point one master and client – „ to “:
Variant 2 Connecon to the Switch G4224T or G4200- 8T/4T
7. Connecon type and wire assignment on device (RJ11 plug)
The G.hn connecon can be established either via one wire pair (connecon type SISO PHONE ) or = G.hn prole “ 200MHz”
via two wire pairs (connecon type MIMO PHONE 100MHz MIMO ). The connecon type must be = G.hn prole “
congured via web interface in both modems or via the G.hn switch.
The default seng PHONE is one wire pair connecon (“ 200MHz”).
Wire assignment SISO
Variant 1 oint- -Point – „P to
Wire assignment SISO
Variant 2 Connecon to Switch
Wire assignment MIMO
Variant 1 Point- -Point – „ to
8. Installaon notes
The wires of a pair can be connected straight or crossed.
Maximum range of the G.hn connecon depends on the type of cable used, the connecon type and the environment.
Typical values for a 0.5 mm twisted pair cable: connecon possible up to approx. 600/800 metres (SISO/MIMO),
maximum bandwidth of 1500 Mbit/s - up to approx. 100/200 metres (SISO/MIMO).
For longer cables ( approx. 100-150m), the bandwidth can be increased by up to 15% (SISO) resp. up to 25% (MIMO) up
by adjusng the signal level. For this purpose, the "Range opmizaon model" must be set to "Long" in the web
interface of both devices resp. the "LongRangeMode" seng must be acvated in the G.hn switch.
The negoated bandwidth can be queried via the web interface of the devices (see point 11).
The bandwidth split of the G.hn connecon is variable. It can be set between 80/20% and 20/80%. In the factory seng,
70% of the bandwidth is reserved for download (direcon master to client) and 30% for upload (direcon client to
master). The allocaon can be congured via master web interface (menu G.hn DownStream / UpStream Rao) resp. via
the G.hn switch.
9. Administraon
10. IP address
The devices do not require IP addresses from the local network segment during operaon, because they transmit the data
trac via the MAC addresses. In the factory seng, they do not obtain any addresses from the local DHCP server.
If desired, stac IP addresses can be congured or the DHCP client can be acvated ("IP" menu in the web interface).
11. Query of the negoated bandwidth
The negoated bandwidths for both direcons can be queried via web interface of each modem. The values shown are
gross data transmission rates on physical layer (PHY). The transmission rate on applicaon layer is approx. -20% lower.15
IP-Adress: 192.168.10.252 (Master), 192.168.10.253 (Client). Login passwort: paterna Factory reset passwort: betera ,
Login via Webinterface
Connect your computer to the G.hn modem via the GE
port..
Assign a xed IP address to your computer, e.g.
192.168.10.100 (network mask 255.255.255.0).
Open a web browser and connect to 192.168.10.252 or
192.168.10.253
Login with the standard password: paterna
It is possible to transmit an analogue telephone line on the same
line parallel to the G.hn signal. Use a DSL splinter for this purpose.

Especificaciones del producto