Greisinger GMH 3750 Manual de Usario
Greisinger
termómetro
GMH 3750
Lee a continuación 📖 el manual en español para Greisinger GMH 3750 (16 páginas) en la categoría termómetro. Esta guía fue útil para 13 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/16

H49.0.02.6B-06
GREISINGER electronic GmbH
D - 93128 Regenstauf, Hans-Sachs-Straße 26
Phone: +49 9402 / 9383-0, Fax: +49 9402 / 9383-33, eMail: info@greisinger.de
Operating Manual Precision Thermometer
as of Version 1.8
Pt100 4-Wire
GMH 3750

H49.0.02.6C-06 Operating Manual GMH 3750 Page 2 of 16
_____________________________________________________ _______________________________________________________________________________
Contents
1 INTENDED USE .........................................................................................................................................3
2 GENERAL ADVICE...................................................................................................................................3
3 SAFETY INSTRUCTIONS ........................................................................................................................3
4 OPERATING AND MAINTENANCE......................................................................................................4
5 CONNECTIONS..........................................................................................................................................4
6 DISPLAY- AND BUTTON ELEMENTS..................................................................................................5
7 START OF OPERATION ..........................................................................................................................5
8 DEVICE CONFIGURATION ....................................................................................................................6
9 SPECIAL FUNCTIONS..............................................................................................................................8
9.1 DISPLAY RESOLUTION..............................................................................................................................8
9.2 USER S CENSOR URVE ('LIN USER')..........................................................................................................8
9.3 ZERO DISPLACEMENT ('OFFSET') ..............................................................................................................8
9.4 SCALE CORRECTION ('SCALE')..................................................................................................................8
9.5 AVERAGE FILTER („T.A G“)...................................................................................................................9U
9.6 OUTPUT („OUT“).....................................................................................................................................9
9.7 ALARM („AL.“)......................................................................................................................................10
9.8 REAL T CIME LOCK („CLOC“) ...............................................................................................................10
10 PROBE CONNECTION........................................................................................................................11
11 CALIBRATION SERVICES ................................................................................................................11
12 OPERATION OF LOGGER.................................................................................................................12
12.1 STORING SINGLE MEASUREMENTS („FUNC-STOR“) ...............................................................................12
12.2 AUTOMATIC RECORDING WITH SELECTABLE LOGGER CYCLE TIME „FUNC CYCL“..............................13
13 SOME BASICS OF PRECISION TEMPERATURE MEASURING ...............................................14
14 FAULT AND SYSTEM MESSAGES...................................................................................................15
15 DISPOSAL NOTES ...............................................................................................................................15
16 SPECIFICATION ..................................................................................................................................16
© Copyright 2008 GREISINGER electronic GmbH. All Rights Reserved.
No part of this documentation may without previous written permission of the company
GREISINGER electronic GmbH stored in some form, reproduced, processed,
duplicated or spread become.

H49.0.02.6C-06 Operating Manual GMH 3750 Page 3 of 16
_____________________________________________________ _______________________________________________________________________________
1 Intended Use
The GMH 3750 is a precision thermometer for the measurement of the temperature with
exchangeable 4-wire Pt100 temperature sensors. With high resolution and precision temperature
values can be measured from -200 to 850 °C.
The device is to be protected against wetness and soiling and has to be stored and operated only
within the permissible environmental conditions and connection data (see “Specification”).
2 General Advice
Read through this document attentively and make yourself familiar to the operation of the device
before you use it. Keep this document in a ready-to-hand way in order to be able to look up in the
case of doubt.
3 Safety Instructions
This device has been designed and tested in accordance to the safety regulations for electronic
devices. However, its trouble-free operation and reliability cannot be guaranteed unless the
standard safety measures and special safety advises given in this manual will be adhered to when
using it.
1. Trouble-free operation and reliability of the device can only be guaranteed if it is not subjected
to any other climatic conditions than those stated under “Specification”.
Transporting the device from a cold to a warm environment condensation may result in a failure
of the function. In such a case make sure
the device temperature has adjusted to the ambient
temperature before trying a new start-up.
2. The circuitry has to be designed most carefully, especially if the device should be connected to
other devices. Internal connection in third party devices (e.g. connection GND and earth) may
result in not-permissible voltages impairing or destroying the device or another device
connected.
3. Warning: Operating the device with a defective mains power supply (e.g. short circuit from
mains voltage to output voltage) may result in hazardous voltages at the device (e.g. at sensor
socket)
4. Whenever there may be a risk whatsoever involved in running it, the device has to be
switched off immediately and to be marked accordingly to avoid re-starting. Operator safety may
be a risk if:
• there is visible damage to the device
• the device is not working as specified
• the device has been stored under unsuitable conditions for a longer time
In case of doubt, please return device to manufacturer for repair or maintenance.
5.
Warning: Do not use these product as safety or emergency stop device, or in any other
application where failure of the product could result in personal injury or material damage.
Failure to comply with these instructions could result in death or serious injury and material
damage.
Especificaciones del producto
Marca: | Greisinger |
Categoría: | termómetro |
Modelo: | GMH 3750 |
¿Necesitas ayuda?
Si necesitas ayuda con Greisinger GMH 3750 haz una pregunta a continuación y otros usuarios te responderán
termómetro Greisinger Manuales

10 Septiembre 2024

27 Agosto 2024

23 Agosto 2024
termómetro Manuales
- termómetro Braun
- termómetro Philips
- termómetro Fysic
- termómetro Inventum
- termómetro Quigg
- termómetro Topcom
- termómetro AnD
- termómetro Amprobe
- termómetro Arendo
- termómetro ATN
- termómetro Aponorm
- termómetro Bartscher
- termómetro Kruidvat
- termómetro Orbegozo
- termómetro Omega
- termómetro Telefunken
- termómetro Thomson
- termómetro Innoliving
- termómetro Tristar
- termómetro Pyle
- termómetro Taylor
- termómetro SereneLife
- termómetro Beurer
- termómetro Melissa
- termómetro Emerio
- termómetro Clatronic
- termómetro Sencor
- termómetro Lanaform
- termómetro Cuisinart
- termómetro Medisana
- termómetro Milwaukee
- termómetro Elro
- termómetro Extech
- termómetro Beper
- termómetro Omron
- termómetro Citizen
- termómetro Hama
- termómetro Cresta
- termómetro Voltcraft
- termómetro Terraillon
- termómetro Velleman
- termómetro Vemer
- termómetro La Crosse Technology
- termómetro Weber
- termómetro Marquant
- termómetro Perel
- termómetro Kyoritsu
- termómetro Homedics
- termómetro Sanitas
- termómetro Auriol
- termómetro Technoline
- termómetro Olympia
- termómetro Cotech
- termómetro Rossmax
- termómetro Vicks
- termómetro Microlife
- termómetro Welch Allyn
- termómetro Testboy
- termómetro Salter
- termómetro Trotec
- termómetro BabyOno
- termómetro Laica
- termómetro Safety 1st
- termómetro TFA
- termómetro Respekta
- termómetro Boso
- termómetro Clas Ohlson
- termómetro Mabis
- termómetro Owon
- termómetro Luvion
- termómetro Irox
- termómetro Konig
- termómetro Reer
- termómetro Miniland
- termómetro Fluke
- termómetro Leifheit
- termómetro Etekcity
- termómetro Ecomed
- termómetro Laserliner
- termómetro Comark
- termómetro Fora
- termómetro Testo
- termómetro Elta
- termómetro Zeiss
- termómetro Beaba
- termómetro Eurochron
- termómetro Grado
- termómetro La Crosse
- termómetro Medel
- termómetro Geratherm
- termómetro Truelife
- termómetro Turbotronic
- termómetro Pacom
- termómetro Westfalia
- termómetro Bioland
- termómetro Oregon Scientific
- termómetro Levita
- termómetro Kerbl
- termómetro Okoia
- termómetro Scala
- termómetro Uebe
- termómetro Duronic
- termómetro Dittmann
- termómetro TFA Dostmann
- termómetro Beha-Amprobe
- termómetro CDN
- termómetro Emga
- termómetro Hartmann
- termómetro VDH
- termómetro ZKTeco
- termómetro Esperanza
- termómetro Pancontrol
- termómetro Uni-T
- termómetro General
- termómetro Ebro
- termómetro Arya
- termómetro RK Technology
- termómetro Bintoi
- termómetro Veroval
- termómetro PeakTech
- termómetro Elem6
- termómetro Thermoval
- termómetro Pasha
- termómetro Innovo
- termómetro Delta Ohm
- termómetro Guide
- termómetro InfiRay
- termómetro Chauvin Arnoux
- termómetro BeSafe
- termómetro PCE Instruments
- termómetro Joy-it
- termómetro Techno Line
- termómetro Klein Tools
- termómetro Knikker
- termómetro FlinQ
- termómetro AvaTemp
- termómetro EasyLife
- termómetro Alter
- termómetro TensCare
- termómetro Yummly
- termómetro Eks
- termómetro Gima
- termómetro Aspen
- termómetro Salva Tec
- termómetro Radiant
- termómetro Kuchenprofi
- termómetro WBTT
- termómetro Welby
- termómetro Prologue
- termómetro A&D
- termómetro ClimeMET
- termómetro Bearware
Últimos termómetro Manuales

27 Octubre 2024

22 Octubre 2024

22 Octubre 2024

22 Octubre 2024

22 Octubre 2024

22 Octubre 2024

20 Octubre 2024

17 Octubre 2024

16 Octubre 2024

16 Octubre 2024