Grüniq GR48-100N Manual de Usario

Lee a continuación 📖 el manual en español para Grüniq GR48-100N (2 páginas) en la categoría No categorizado. Esta guía fue útil para 4 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/2
888
888
1x 1x
During the installation, do not connect the positive and negative poles reversely,
incorrect connection will cause damage to the product.
1. Connect every 2pcs 24V solar penal in series, and every 4pcs in parallel.
2. Connect the wires of the battery board junction box to the 3-way connector according
kW
Notes for Usage
to the positive and negative poles.
3. Connect the cable on the 3-way connector to the integrated reverse control machine rst,
and then charge BCT-UU 48-100.
P k P s c drevent knoc reven allt f Don’t dis ar
P treven
disas embls y
P revent add
ot tsher produc
K yeep awa
f prom the dam
K yeep awa
f erom t fhe ir
Installation Condition
If this product uses the pv module for charging, the pv module need to be installed in light sucient place,
and blockage by any occlusion or shadow on the surface should be avoided to guarantee the working time,
otherwise the working time decreases in proportion to the photovoltaic module being blocked time.
All GRÜNIQ Lithium batteries have an integrated BMS ( Battery Management System).
There is no direct communication between the BMS and inverter. Battery will be dened while setting up
the inverter as user. This option ensures durability, stability and longer battery lifespan.
Storage and Transportation
01. Based on the character of cell, proper environment for transportation of LiFePO4 battery pack
need to be created to protect the battery.
02. If it is not used for the time being, short term (within 1 month) : battery should be stored
at -20°C to 40°C; long term (within 1 year) : battery should be stored in 10 °C to 35 °Cthe battery
should be stored in a dry, clean and well ventilated warehouse, and the re source should
be isolated.
03. During loading of battery, attention must be paid against dropping, turning over and serious stacking.
04. LiFePO4 battery pack should be properly protected during storage and transportation to
maintain a SOC level of about 50% to ensure that no short circuit or liquid enters the LiFePO4
battery pack or is immersed in a liquid (e.g. water, oil, etc.).
Maintenance
01. When installing in a dusty or seriously hazy area, such as coal yard/mining operation, etc.,
the surface of the solar panel should be clean intermittently.
02. Snow on solar panels should be cleaned intermittently.
03. If bolts ever become loose, tighten them immediately.
Statement
01. The manufacturer will not undertake any loss caused by earthquake, ood, thunder or any
other natural disasters, res not caused by the product itself and theft and damage caused
by accidents
02. The manufacturer will not undertake any loss by customers connecting the product with other
unmatched devices or installing in inadequate conditions.
03. The battery pack should not be used under overvoltage. The open circuit voltage of the
12V battery pack cannot exceed 22V; the open circuit voltage of the 24V battery pack cannot
exceed 44V; the open circuit voltage of the 48V battery pack cannot exceed 88V.
Our company is not responsible for any loss caused by re or other faults caused
by over-voltage use.
* The below damage is not within warranty:
1. Wrong connection between positive and negative.
2. Overload of electrical appliances.
3. The outlook is badly broken(because of human damagescrapefall downassemble the products).
4. Water in (when product is placed under rain and not protected from wet areas).
5. If use any other not belong to standard accessories add to the Smart Power result in goes bad
(led or Don’t discard other equipment not match the Smart Power).
When using the products please keep away from the re, please not through freely.
6. Damage caused by not following the instructions.
Attention
01. It is forbidden to use any high-voltage to charge it. Otherwise the BMS components of the
battery will be burned out due to the high-voltage, resulting in the failure of overcharge protection.
As a result, the battery is overcharged, causing the battery heat out of control and re hazards.
The open circuit voltage of 12V battery pack can not exceed 22V, 24V battery pack can not exceed
44V and 48V battery pack cannot exceed 88V. The maximum open circuit voltage of solar panel
cannot exceed twice of the battery voltage.
02. Please use a MPPT controller with lithium iron phosphate battery mode. It is strictly prohibited to
use any inverter and controller integrated equipment or charge controller which match the lead acid
battery to connect the lithium battery, to avoid overcharging of lithium battery and potential re
hazards due to high voltage of solar panel. Also afterthe battery is fully charged, the lead-acid battery
controller continues to charge; thus the BMS of lithium battery cannot work normally.
03. Output must have high-voltage isolation function when using high-voltage inverter and MPPT
controller integrated equipment with lithium battery mode. Ensure that the battery is still in a safe
state in case of MPPT failure.
04. When the source voltage of the charging terminal is higher than 88V, the high voltage circiut breaker
with charging protection function must be connected between the charging controller and the battery,
in order to prevent the failure of the voltage conversion device in the middle and cause overcharging
of the battery.
05. 12V battery pack, maximum support 4 battery packs in series, the highest charging voltage of
4 battery packs in series is less than 88V, and the highest charging voltage of 2 battery packs in
series is less than 44V. 24V battery pack, maximum support 2 battery packs in series, the highest
charging voltage of 2 battery packs in series is less than 88V. 48V battery pack, it is forbidden to
use in series. Ensure the batteries are discharged to empty condition or fully charged before
connecting them in series. Ensure the voltage of batteries are consistent before connecting the
batteries in parallel
06. It is forbidden to connect the positive and negative poles reversely and short circuit the positive
and negative poles of the battery pack; The overload is strictly prohibited.
07. The battery pack should not be used in severe vibration scenarios.
08. It is strictly prohibited to put in water and clean the battery pac and do not place the product in
the outdoor exposed place for a long time to prevent rain or moisture.
09. The battery should not be placed in the room where any combustilble gas or ammable items are
stored, and should be used in a clean, dry and ventilated environment.
10. It is strictly prohibited to knock, throw, reverse or trample on the battery pack. It is strictly
prohibited to use the battery pack when the appearance is seriously damaged (articial knocking,
scraping, falling from height, unauthorized disassembly of the products, etc.).
11. Can connect in parallel up to 2 pcs.
12. During installation and electrical applicances installation, the DC voltage of the solar system may
be twice more than the voltage of system (e.g. 12V system with 24V, 24V system with 48V) , so it is
important to use well-insulated tools.
13. Do not use any measuring tools that are damaged or defective.
14. When you install the system, make sure the re protection measures do not fail. Do no store the
product indoors where any combustible gas or gas mixture is stored.
15. The symbols, logos and labels on the outer surface of the product cannot be modied or removed
without notice.
16. All installation work must be carried out under international electrical specications and related
local congurations.
17. Smoking, naked ame and connecting to unprotected lamps are prohibited while operating
batteries; Keep away from re when using.
18. Never cut through the product with nail or other edge tool.
19. Never ship or store the product together with metal.
20. Never throw the product into re or heating machine to avoid re, explosion and environment
pollution; scrap product should be returned to the supplier and handled by the recycle station.
21. Never use the product under strong static and strong magnetic eld, otherwise it will destroy the
protecting device.
22. The product should be stored in half SOC. It needs to be charged once if out of use for as
long as half a year.
23. Prior to charging, fully check the insulativity, physical condition and ageing status, since breakage
and ageing are never allowed.
24. The restricted use current marked on the product is not applicable to the inductive load. Under
normal conditions, the instantaneous start current of the inductive load is three times that
of the normal operation.
GR48-100N
www.grueniq.de

Especificaciones del producto

Marca: Grüniq
Categoría: No categorizado
Modelo: GR48-100N

¿Necesitas ayuda?

Si necesitas ayuda con Grüniq GR48-100N haz una pregunta a continuación y otros usuarios te responderán




No categorizado Grüniq Manuales

No categorizado Manuales

Últimos No categorizado Manuales