Haier GV110REMB Manual de Usario
Haier
Calderas y calderas
GV110REMB
Lee a continuación 📖 el manual en español para Haier GV110REMB (8 páginas) en la categoría Calderas y calderas. Esta guía fue útil para 11 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/8
Please read through the manual before use.
Please keep the manual for future reference.
Table of Contents
1
2
2
2-6
6
7
7
User Manual
Haier Solar Water Heater
Models
GV150REMB
GV200REMB
GV270REMB
GV110RNMB(*)
*:Model without electric
auxiliary heating function.
Safety cautions
Product features
Technical parameters
Installation instructions
Operation instructions
Troubleshooting
Packing list
Description
of symbols
Behaviors that
are prohibited
Directions that
must be followed.
Directions that
must be noted.
The water heater is non-pressurized, gravity-fed water heater relying on the height difference
of the water tank and point of use to supply hot water with the outgoing water pressure in
direct proportion to the height. An additional pressurizer may be required.
Please clean the glass vacuum tubes before the winter comes. Keep their surface clean to
maintain heat collection efficiency.
where it's very cold in the winter, we recommend you select our optional solar
energy heater controller with anti-freeze function.
In the area
Warning! Improper operation of the following may lead to personal injury or even death!
Do not touch glass vacuum tube,
pipes and valves for supplying
hot water during use to avoid
being burned.
Please feel the water temperature
by hand before use to make sure
of proper water temperature while
in use
Personnel other than professional
maintenance staff are prohibited
from repairing, maintenance,
dismantling or altering the water
heater without authorization.
Caution! Improper operation of the following may lead to personal injury or even death or property loss!
- -Suggestions
The glass vacuum tube shall not be
exposed for a long period without water
inside after installation to avoid the
shortening of the service life. If it cannot
be used immediately, it shall be covered.
The water heater is equipped with a
special venting pipe and overflow pipe.
To ensure normal operation, \never refit
or plug their outlets. Otherwise the water
tank will shrink.
Water shall be fed in early morning or at
night when the sunlight is insufficient. The
water feeding after sunlight exposure of
the glass vacuum tube will cause an
explosion of the pipe.
The
temperature of the hot water delivered
may not satisfy your requirement. If there
is no electric heating as an auxiliary
energy source, it may be unable to be
used normally.
Water shall be fed in early morning or at
night when the sunlight is insufficient.
Safety cautions (please read the cautions before use)
Caution
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Prohibit
Prohibit
Prohibit
Prohibit
Prohibit
Please do not use the hot water in the
heater for drinking or similar purposes.
To guarantee effectiveness, do not feed
water to the heater several times within
one day in case of insufficient sunlight
exposure.
The glass vacuum tubes can withstand
a low temperature of -70 when they
are not filled with water. When the
auxiliary heating device is not to be used,
on continuous cloudy days in winter or
when the tubes are covered by snow, be
sure to keep the water tank full of water
and replace the cold water in the tank
frequently (every 2 days). Otherwise the
water retained in the tank will cause the
vacuum tubes to break.
When the heater with auxiliary electric
heating function is used, ensure the
auxiliary electric heater and electric
heating accompanying strap are in OFF
state.
Technical parameters
4.Tower type frame
The tower type frame, made of carbon steel by means of spray processing, has the
advantages of a stable structure, attractive appearance and co
1.The water heater shall be
lightening protected area
prone to lightning strikes.
2.The orientation of the wat
3.There must be no shieldin
installation location of the
exists, the space between
objective shall be more th
10 south by east and 15
Northern Hemisphere;
10 north by west and 15
Southern Hemisphere.
°
°
Installation instructions
Selection of installation location
Note:The deviation of the aperture area is 3%; the deviation o
the permitted error limit of other parameters is 10%.
(wherein: H-height of the sh
latitude)
Model
Number of the
glass vacuum tubes
Aperture area
Usable water
Total water volume
Electric auxiliary heating
Specifications of the
glass vacuum tubes
58mm X 1800mm,
all-glass vacuum tube solar heat
1500W/220V
16 22
12
150L 200
110L
2.07m22.90
1.58m2
195L 253
141L
GV150REMB GV200R
GV110RNMB
;
Horizontal 45°
None
Frame form
Especificaciones del producto
Marca: | Haier |
Categoría: | Calderas y calderas |
Modelo: | GV110REMB |
¿Necesitas ayuda?
Si necesitas ayuda con Haier GV110REMB haz una pregunta a continuación y otros usuarios te responderán
Calderas y calderas Haier Manuales
4 Octubre 2024
13 Septiembre 2024
28 Agosto 2024
28 Agosto 2024
21 Agosto 2024
9 Agosto 2024
7 Agosto 2024
30 Julio 2024
Calderas y calderas Manuales
- Calderas y calderas Electrolux
- Calderas y calderas ATAG
- Calderas y calderas Bosch
- Calderas y calderas AEG
- Calderas y calderas Philips
- Calderas y calderas Panasonic
- Calderas y calderas Junkers
- Calderas y calderas Nefit
- Calderas y calderas Remeha
- Calderas y calderas Siemens
- Calderas y calderas Whirlpool
- Calderas y calderas Vaillant
- Calderas y calderas ACV
- Calderas y calderas GE
- Calderas y calderas Orbegozo
- Calderas y calderas Fagor
- Calderas y calderas Gorenje
- Calderas y calderas Hitachi
- Calderas y calderas Cata
- Calderas y calderas Hisense
- Calderas y calderas Vox
- Calderas y calderas Taurus
- Calderas y calderas Hotpoint
- Calderas y calderas Sencor
- Calderas y calderas Midea
- Calderas y calderas De Dietrich
- Calderas y calderas Daikin
- Calderas y calderas Truma
- Calderas y calderas Intergas
- Calderas y calderas Stiebel Eltron
- Calderas y calderas Buderus
- Calderas y calderas Dometic
- Calderas y calderas Aspes
- Calderas y calderas Elco
- Calderas y calderas Dimplex
- Calderas y calderas Masterwatt
- Calderas y calderas Nibe
- Calderas y calderas Ferroli
- Calderas y calderas Ariston Thermo
- Calderas y calderas Elba
- Calderas y calderas Corberó
- Calderas y calderas Kelvinator
- Calderas y calderas Mora
- Calderas y calderas Buffalo
- Calderas y calderas Viessmann
- Calderas y calderas Jocel
- Calderas y calderas Worcester
- Calderas y calderas Atlantic
- Calderas y calderas Technika
- Calderas y calderas Plieger
- Calderas y calderas Bulex
- Calderas y calderas Tesy
- Calderas y calderas Waeco
- Calderas y calderas AWB
- Calderas y calderas HTW
- Calderas y calderas Edilkamin
- Calderas y calderas OSO
- Calderas y calderas Kunft
- Calderas y calderas La Nordica
- Calderas y calderas Clage
- Calderas y calderas Noveen
- Calderas y calderas Joven
- Calderas y calderas Daalderop
- Calderas y calderas Cointra
- Calderas y calderas Baxi
- Calderas y calderas Rommer
- Calderas y calderas Morco
- Calderas y calderas Sentry
- Calderas y calderas Keston
- Calderas y calderas Wesen
- Calderas y calderas Khind
- Calderas y calderas SolarEdge
- Calderas y calderas Dux
- Calderas y calderas Intellihot
- Calderas y calderas Airthereal
- Calderas y calderas Thermoflow
- Calderas y calderas IStore
- Calderas y calderas Apricus
- Calderas y calderas Aquamarin
- Calderas y calderas Rinnai
- Calderas y calderas Sime
- Calderas y calderas Kospel
- Calderas y calderas Neopower
- Calderas y calderas My-PV
- Calderas y calderas Rheem
- Calderas y calderas Mission Air
- Calderas y calderas Solahart
- Calderas y calderas ENEFT
- Calderas y calderas AquaTech
- Calderas y calderas Imarflex
- Calderas y calderas MicroHeat
- Calderas y calderas Noritz
Últimos Calderas y calderas Manuales
26 Octubre 2024
23 Octubre 2024
22 Octubre 2024
22 Octubre 2024
22 Octubre 2024
22 Octubre 2024
22 Octubre 2024
22 Octubre 2024
22 Octubre 2024
22 Octubre 2024