Heat Pump Water Heater
Controller Operation Guide
Models:
HP200M1- U1
HP250M1-U1
Power ON/OFF.
Mode selection. Press the MODE key to switch
between the four working modes of AUTO, ECO,
ELEC, and VAC.
Adjust the clock settings. Set the time of day in
hours/minutes.
Used to set timer functions/confirm changes to
settings.
Set the temperature and time. Press and hold
for continuous adjustment.
Turns a one-time boost heating function on or
off, using both the heat pump and back- up
electrical element, decreasing the heating time.
The heat pump will operate at any time to
provide hot water when the demand is required.
Operates the heat pump to provide hot water
only during the “off peak” power period or -
when there is an off-peak power signal. Manual
set time, Automatic off-peak signal or
Photovoltaic solar supplementary.
Will only use the electrical element for heating.
This function should only be used if there is a
fault with the heat pump module so that hot
water can be supplied to the user.
Vacation mode: Maintains a minimum water
temperature to save power, then reheats the
water in advance of the return date set by the
user.
Anti-Legionella, sterilizes your stored water
against Legionella, the service will automatically
turn on once every 7 days and raise the
temperature to 65°C, or as user defined.
Stored water temperature display. Bars indicate
temperature variations only and not water
volume.
Heat pump in operation indicator.
Electric heating in operation indicator.
HC
Switching signal of the power supply is active.
PV
Supplementary photovoltaic (PV) solar power
supply signal is active.
Lock screen display icon.
Start Up Controls
This guide is designed to better explain the controls and operation of the basic modes currently
available to you with your Heat Pump Water Heater.
01. Temperature and Time
02. AUTO mode (Automatic operation)
03. ELEC mode (Electric element)
04. VAC mode (Vacation)
05. BOOST function
06. Lock screen
07. Service mode (advanced settings)
08. Fault codes (advanced settings)
01. Temperature and Time
01.1 Temperature
1. Turn on the appliance by pressing the key if in Standby, otherwise disregard this step.
_
2. Press or keys to adjust the temperature increments until the desired temperature is reached the +–in 1℃.
Note: A minimum of 60 is recommended for stored hot water to help prevent undesirable bacteria. ℃
_ _
3. Once the desired set temperature is displayed, the settings will be confirmed after 6 seconds of keyless
operation and you will return to the operational mode.
01.2 Time
1. Turn on the appliance by pressing the key if in Standby, otherwise disregard this step.
_
2. Press the T
T
T
TTIMER
IMER
IMER
IMERIMER key until the display shows the hours flashing “00
00
00
0000:00.”
_ _
3. Press or key to adjust the 24 hour time. the +–
_ _ _
4. Press the T
T
T
TTIMER
IMER
IMER
IMERIMER key until the display shows the minutes flashing “00:00
00
00
0000.”
_ _ _ _
5 Press or key to adjust the minutes. . the +–
_ _ _ _ _
6 Once the current time is displayed, the settings will be confirmed after 6 seconds of keyless operation and you .
will return to the operational mode.
02. AUTO mode
Note: This appliance must be connected to a power supply providing electricity 24 hours per day. This
mode is designed to automatically operate the heat pump when the temperature has dropped by a
specified amount, just like a thermostatically controlled hot water cylinder.
AUTO Mode (under default settings)
1. Turn on the appliance by pressing the key.
_
2. Press keys until the display shows the icon. the MODE
MODE
MODE
MODEMODE AUTO
AUTO
AUTO
AUTOAUTO
_ _
3. Press or key to adjust the temperature to the desired settings as described in step . A minimum of the +–01.1
60 is recommended. ℃
_ _ _
4. Your appliance should begin to operate in AUTO mode to reach the set temperature. It may take up to 5
minutes for the heat pump to initiate operation.
_ _ _ _
5 If hot water is required as soon as possible after installation, the key can operate the electric . BOOST
BOOST
BOOST
BOOSTBOOST
element in addition to the heat pump for a faster recovery. This is not a working mode but will assist until the set
temperature is reached, returning to the previous working mode. As this is an energy efficient appliance, the heat
pump should remain the main source of heating wherever possible.
_ _ _ _ _
6 Your appliance should reach the set temperature and hot water will be available for use. .
_ _ _ _ _ _
7 The default temperature differential is 10 for the HP200 model and 9 for the HP250 model. This means that . ℃ ℃
at any time of the day or night, when the actual water temperature drops by this amount below the set
temperature, the heat pump will operate. The temperature differential can be adjusted in the Service mode further
in this guide.
03. ELEC mode
Note: This mode is designed to provide heating if the heat pump is not operating for any reason.
If there is a fault with the heat pump module, follow this guide to ensure available hot water until a
technician can resolve the issue.
1. Turn on the appliance by pressing the key if in Standby, otherwise disregard this step.
_
2. Press keys until the display shows the icon. the MODE
MODE
MODE
MODEMODE ELEC
ELEC
ELEC
ELECELEC
ELEC
ELEC
ELEC
ELECELEC
_ _
3. The water heater should now heat via the electric element until the set temperature is reached.
The element icon will be displayed to indicate its operation.
_ _ _
4. If there is a fault with the heat pump module, call Fisher & Paykel for service support.
Especificaciones del producto
Marca: | Haier |
Categoría: | Calderas y calderas |
Modelo: | HP200M1-U1 |
¿Necesitas ayuda?
Si necesitas ayuda con Haier HP200M1-U1 haz una pregunta a continuación y otros usuarios te responderán
Calderas y calderas Haier Manuales
4 Octubre 2024
13 Septiembre 2024
28 Agosto 2024
28 Agosto 2024
21 Agosto 2024
9 Agosto 2024
7 Agosto 2024
30 Julio 2024
Calderas y calderas Manuales
- Calderas y calderas Electrolux
- Calderas y calderas ATAG
- Calderas y calderas Bosch
- Calderas y calderas AEG
- Calderas y calderas Philips
- Calderas y calderas Panasonic
- Calderas y calderas Junkers
- Calderas y calderas Nefit
- Calderas y calderas Remeha
- Calderas y calderas Siemens
- Calderas y calderas Whirlpool
- Calderas y calderas Vaillant
- Calderas y calderas ACV
- Calderas y calderas GE
- Calderas y calderas Orbegozo
- Calderas y calderas Fagor
- Calderas y calderas Gorenje
- Calderas y calderas Hitachi
- Calderas y calderas Cata
- Calderas y calderas Hisense
- Calderas y calderas Vox
- Calderas y calderas Taurus
- Calderas y calderas Hotpoint
- Calderas y calderas Sencor
- Calderas y calderas Midea
- Calderas y calderas De Dietrich
- Calderas y calderas Daikin
- Calderas y calderas Truma
- Calderas y calderas Intergas
- Calderas y calderas Stiebel Eltron
- Calderas y calderas Buderus
- Calderas y calderas Dometic
- Calderas y calderas Aspes
- Calderas y calderas Elco
- Calderas y calderas Dimplex
- Calderas y calderas Masterwatt
- Calderas y calderas Nibe
- Calderas y calderas Ferroli
- Calderas y calderas Ariston Thermo
- Calderas y calderas Elba
- Calderas y calderas Corberó
- Calderas y calderas Kelvinator
- Calderas y calderas Mora
- Calderas y calderas Buffalo
- Calderas y calderas Viessmann
- Calderas y calderas Jocel
- Calderas y calderas Worcester
- Calderas y calderas Atlantic
- Calderas y calderas Technika
- Calderas y calderas Plieger
- Calderas y calderas Bulex
- Calderas y calderas Tesy
- Calderas y calderas Waeco
- Calderas y calderas AWB
- Calderas y calderas HTW
- Calderas y calderas Edilkamin
- Calderas y calderas OSO
- Calderas y calderas Kunft
- Calderas y calderas La Nordica
- Calderas y calderas Clage
- Calderas y calderas Noveen
- Calderas y calderas Joven
- Calderas y calderas Daalderop
- Calderas y calderas Cointra
- Calderas y calderas Baxi
- Calderas y calderas Rommer
- Calderas y calderas Morco
- Calderas y calderas Sentry
- Calderas y calderas Keston
- Calderas y calderas Wesen
- Calderas y calderas Khind
- Calderas y calderas SolarEdge
- Calderas y calderas Dux
- Calderas y calderas Intellihot
- Calderas y calderas Airthereal
- Calderas y calderas Thermoflow
- Calderas y calderas IStore
- Calderas y calderas Apricus
- Calderas y calderas Aquamarin
- Calderas y calderas Rinnai
- Calderas y calderas Sime
- Calderas y calderas Kospel
- Calderas y calderas Neopower
- Calderas y calderas My-PV
- Calderas y calderas Rheem
- Calderas y calderas Mission Air
- Calderas y calderas Solahart
- Calderas y calderas ENEFT
- Calderas y calderas AquaTech
- Calderas y calderas Imarflex
- Calderas y calderas MicroHeat
- Calderas y calderas Noritz
Últimos Calderas y calderas Manuales
26 Octubre 2024
23 Octubre 2024
22 Octubre 2024
22 Octubre 2024
22 Octubre 2024
22 Octubre 2024
22 Octubre 2024
22 Octubre 2024
22 Octubre 2024
22 Octubre 2024