IMPORTANT SAFEGUARDS
This manual contains important safety instruction that should be followed during the
installation and maintenance of the UPS and its batteries. Please read this manual
thoroughly before attempting to install or operate in this UPS.
1. Read all instructions carefully.
2. This equipment is available for 220Va.c-240Va.c. supply voltage and loads.
3. This UPS is designed for normal use only. The manufacturer neither recommends
nor knowingly sells this product for use in critical life support application.
4. Connect only to main supply socket outlet with an earth connector. A means of
disconnection of the main supply should be within 2 meters of the UPS.
5. WARNING: Output sockets of the UPS are electrically live if the UPS is switched ON,
even if the UPS is not plugged in to the main supply. The ON/OFF button of the UPS
does not electrically isolate the internal parts. To isolate the UPS, switch OFF the
UPS rst, and then unplug it from the main supply.
To reduce the risk of electric shock, do not remove the cover, as it has no user-
serviceable parts inside. Some components are live, even when the AC power is
disconnected. Bring the unit to Imarex Authorized Service Center to obtain
evaluation and repair.
SPECIFICATION
Model
UPS- 850G
Rated Power
850Va.c
Backup Power
450W
Input
90V-140V/165V-275V/175V-295V
AVR Range
100V 265V-124V/190V-246V-195V-
Output
120±10%/230±10%/240±10%
Frequency
50Hz/60Hz
Battery (double)
Type
Sealed, maintenance-free lead acid
Capacity
One 12V/9Ah
Two 12V/7Ah
Back-up time (half Load)
Over 12 minutes
Typical Recharge Time
8 hours
LCD indicators
Status
Normal, Fault, Battery, Over Load, Output
Voltage, Battery Level
Audible Alarm
Battery Mode
Beeping sound every four seconds, every
second if approaches nal discharge
Fault (overload)
Continuous beeping sound
Operating
Environment
Temperature
-5°C-40°C
Humidity
10-90% RH, non-condensing
Audible Noise
< 45dBA
Transfer time
< 10 ms
Net Weight
6.8 Kg
10.6 Kg
Dimension (WxDxH)
300x115x220 mm
335x140x230 mm
To reduce the risk of re or electric shock, install the UPS in a temperature
controlled room, free of conductive contaminants.
6. This unit is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have
been given supervision or instruction concerning use of the appliances by a person
responsible for their safety.
7. Children should be supervised to ensure that they do not play with the UPS.
8. The UPS relies on your building wiring over-current protection, which must be rated
between 4-5 amperes (220Va.c. rating voltage).
9. When using the communication features on the UPS, ensure that the cabling
connected to USB communication port of the network connection are kept separated
by 25mm from the power cords to the UPS input and output.
10. CAUTION:
Although your UPS has been designed and manufactured to assure personal safety,
improper use can result to in electrical shock or re. To insure safety, please observe
the following rules.
Turn o and unplug your UPS before cleaning. Do not use liquid or aerosol
cleaners. A dry cloth is recommended to remove dust from the surface of your
UPS.
Do not install or operate your UPS near water.
Do not place UPS on unstable stand or table.
Do not place UPS under direct sunlight or close to heat emitting sources.
Do not place UPS power cord in any area where it may get damaged by heavy
objects.
Follow all warnings and instruction marked on the UPS.
11. ATTENTION:
Turn OFF and unplug the UPS from the convenience outlet and contact or bring the
UPS to Imarex Authorized Service Center if;
The power cord or plug damaged.
Liquid has been spilled on the UPS and it emits smoke.
The fuse blows frequently.
The UPS does not operate even when user follows the operating instruction.
12. CONDITION OF USE:
Your UPS provides conditioned power to connected equipment. Maximum load must
not exceed that shown on the UPS pop sticker.
13. REPLACE OF BATTERIES
The UPS requires battery replacement by a qualied Imarex technician.
Contact the Imarex Authorized Service Center to obtain battery replacement. It
must be the same type and rating as the original battery.
14. Save this instruction manual for referenc e.